Comparison of fire extinguishing performance of four halon substitutes and Halon 1301

被引:15
|
作者
Wang, Yawei [1 ]
Zou, Gaowan [1 ]
Liu, Conglin [1 ]
Gao, Y. [1 ]
机构
[1] Harbin Engn Univ, Coll Aerosp & Civil Engn, 145 Nantong St, Harbin 150001, Heilongjiang, Peoples R China
关键词
ISO9705; room; fire extinguishing tests; halon substitutes; fire extinguishing efficiency; OXYGEN-CONSUMPTION; HEAT RELEASE; AGENTS;
D O I
10.1177/07349041211030188
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The Halon 1301 fixed gas fire extinguishing system used in ship engine rooms has been banned from production all over the world, because halon destroys the ozone layer. Therefore, it is necessary to find an environmentally friendly, compatible and efficient alternative firefighting system. In this study, we performed fire extinguishing tests in an ISO9705 standard room for four alternative fire extinguishing agents, as well as Halon 1301. The fire extinguishing efficiency of each agent was determined based on its cooling effect, dilution effect of oxygen concentration, the extinguishing time of the oil pool fire and the re-ignition probability of the wood stack. The test results provide data support for the selection of alternatives of Halon 1301 from the aspect of fire extinguishing efficiency. Among these results, Novec 1230 had the best ability to put out the oil pool fire, and HFC-227ea suppressed the wood stack fire the best. The difference between the cooling ability of each fire extinguishing agent was small, and the inert gas (IG-541) displayed the best ability to dilute oxygen. Hot aerosol required the longest time to extinguish fire. Consequently, under the existing design standards, HFC-227ea had the better firefighting efficiency, more suitable to replace Halon 1301.
引用
收藏
页码:370 / 399
页数:30
相关论文
共 50 条
  • [21] Pyrolysis of Halon 1301 over zeolite catalysts
    Li, K
    Oghanna, F
    Kennedy, E
    Dlugogorski, B
    Fazeli, A
    Thomson, S
    Howe, R
    [J]. MICROPOROUS AND MESOPOROUS MATERIALS, 2000, 35-6 : 219 - 226
  • [22] USE OF HALON-1301 IN A HOSPITAL - RESPONSE
    REINHART, CF
    SPROUT, WL
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1984, 26 (09) : 634 - 634
  • [23] Modeling cardiac sensitization potential of humans exposed to Halon 1301 or Halon 1211 aboard aircraft
    Vinegar, A
    [J]. AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2001, 72 (10): : 928 - 936
  • [24] Mathematical modeling of nitrogen-pressurized Halon flow in fire extinguishing systems
    Amatriain, Aitor
    Rubio, Gonzalo
    Parra, Ignacio
    Valero, Eusebio
    Andreu, David
    Martin, Pedro Manuel
    [J]. FIRE SAFETY JOURNAL, 2021, 122
  • [25] The US Army requirement for a replacement for Halon 1301
    Finnerty, AE
    [J]. HALON REPLACEMENTS: TECHNOLOGY AND SCIENCE, 1995, 611 : 161 - 174
  • [26] A process for disposal of halon 1301 (CBrF3)
    Kennedy, EM
    Li, K
    Moghtaderi, B
    Dlugogorski, BZ
    [J]. CHEMICAL ENGINEERING COMMUNICATIONS, 1999, 176 : 195 - 200
  • [27] US Navy halon 1301 simulant identification project
    Leach, W
    [J]. NAVAL ENGINEERS JOURNAL, 1996, 108 (05) : 57 - 59
  • [28] EXTINGUISHMENT OF CLASS-B FIRES WITH HALON 1301
    WIERSMA, SJ
    ALGER, RS
    [J]. JOURNAL OF FIRE & FLAMMABILITY, 1978, 9 (01): : 99 - 118
  • [29] Assessment of Halon-1301 as a groundwater age tracer
    Beyer, M.
    van der Raaij, R.
    Morgenstern, U.
    Jackson, B.
    [J]. HYDROLOGY AND EARTH SYSTEM SCIENCES, 2015, 19 (06) : 2775 - 2789
  • [30] FIRE WARNING SYSTEM ELIMINATES HALON
    不详
    [J]. PROFESSIONAL ENGINEERING, 1995, 8 (20) : 36 - 36