Construction of an automated gas chromatography/mass spectrometry system for the analysis of ambient volatile organic compounds with on-line internal standard calibration

被引:34
|
作者
Su, Yuan-Chang [1 ]
Chang, Chih-Chung [2 ]
Wang, Jia-Lin [1 ]
机构
[1] Natl Cent Univ, Dept Chem, Chungli 320, Taiwan
[2] Acad Sinica, Res Ctr Environm Changes, Taipei 11529, Taiwan
关键词
volatile organic compounds (VOCs); gas chromatography/mass spectrometry (GC/MS); internal standard (IS);
D O I
10.1016/j.chroma.2008.03.071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated sampling and enrichment apparatus coupled with a gas chromatography/mass spectrometry (GC/MS) technique was constructed for the analysis of ambient volatile organic compounds (VOCs). A sorbent trap was built within the system to perform on-line enrichment and thermal desorption of VOCs onto GC/MS. In order to improve analytical precision, calibration accuracy, and to safe-guard the long-term stability of this system, a mechanism to allow on-line internal standard (I.S.) addition to the air sample stream was configured within the sampling and enrichment apparatus. A sub-ppm (v/v) level standard gas mixture containing 1,4-fluorobenzene, chloropentafluorobenzene, 1-bromo-4-fluorobenzene was prepared from their pure forms. A minute amount of this I.S. gas was volumetrically mixed into the sample stream at the time of on-line enrichment of the air sample to compensate for measurement uncertainties. To assess the performance of this VOC GC/MS system, a gas mixture containing numerous VOCs at sub-ppb (v/v) level served as the ambient air sample. Various internal standard methods based on total ion count (TIC) and selective ion monitoring (SIM) modes were attempted to assess the improvement in analytical precision and accuracy. Precision was improved from 7-8% RSD without I.S. to 2-3% with I.S. for the 14 target VOCs. Uncertainties in the calibration curves were also improved with the adoption of I.S. by reducing the relative standard deviation of the slope (Sm%) by an average a factor of 4, and intercept (Sb%) by a factor of 2 for the 14 target VOCs. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:134 / 140
页数:7
相关论文
共 50 条
  • [21] Construction and validation of automated purge-and-trap-gas chromatography for the determination of volatile organic compounds
    Wang, JL
    Chen, WL
    JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) : 143 - 154
  • [22] On-line coupling of thermal extraction with gas chromatography/tandem mass spectrometry for the analysis of semivolatile organic compounds in a few milligrams of indoor dust
    Mercier, Fabien
    Gilles, Erwann
    Soulard, Pauline
    Mandin, Corinne
    Dassonville, Claire
    Le Bot, Barbara
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1615
  • [23] On-line trace monitoring of volatile halogenated compounds in air by improved thermal desorption-gas chromatography-mass spectrometry
    Jiang, Jiakui
    Ji, Yongyan
    Li, Xiang
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1682
  • [24] Proton Transfer Reaction Mass Spectrometry for On-line Detection of Trace Volatile Organic Compounds in Breath
    Shen Cheng-Yin
    Li Jian-Quan
    Wang Hong-Zhi
    Zhi Zhong-Hua
    Wang Hong-Mei
    Huang Chao-Qun
    Liu Sheng
    Jiang Hai-He
    Chu Yan-Nan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (05) : 773 - 777
  • [25] Measurement of volatile plant compounds in field ambient air by thermal desorption–gas chromatography–mass spectrometry
    Xiao-Ming Cai
    Xiu-Xiu Xu
    Lei Bian
    Zong-Xiu Luo
    Zong-Mao Chen
    Analytical and Bioanalytical Chemistry, 2015, 407 : 9105 - 9114
  • [26] Analysis of airborne volatile organic compounds of a steel industry by solid phase microextraction and gas chromatography/mass spectrometry
    Parreira, FV
    de Carvalho, CR
    Cardeal, ZD
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2003, 70 (05) : 957 - 963
  • [27] Analysis of volatile organic compounds in human urine by headspace gas chromatography-mass spectrometry with a multipurpose sampler
    Wahl, HG
    Hoffmann, A
    Luft, D
    Liebich, HM
    JOURNAL OF CHROMATOGRAPHY A, 1999, 847 (1-2) : 117 - 125
  • [28] Multisorbent thermal desorption/gas chromatography-mass spectrometry for analysis of volatile organic compounds in industrial sewage
    Chen, YX
    You, J
    Liang, B
    Chen, SL
    Wang, GJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (02) : 262 - 262
  • [29] Analysis of Airborne Volatile Organic Compounds of a Steel Industry by Solid Phase Microextraction and Gas Chromatography/Mass Spectrometry
    F. V. Parreira
    C. R. de Carvalho
    Z. de Lourdes Cardeal
    Bulletin of Environmental Contamination and Toxicology, 2003, 70 : 0957 - 0963
  • [30] GAS-CHROMATOGRAPHY MASS-SPECTROMETRY ANALYSIS OF VOLATILE ORGANIC-COMPOUNDS PRODUCED BY SOME MICROMYCETES
    CAILLEUX, A
    BOUCHARA, JP
    DANIEL, V
    CHABASSE, D
    ALLAIN, P
    CHROMATOGRAPHIA, 1992, 34 (11-12) : 613 - 617