Self-calibrating sensor with logic gate operation for anthrax biomarker based on nanoscaled bimetallic lanthanoid MOF

被引:74
|
作者
Othong, Jintana [1 ,2 ]
Boonmak, Jaursup [1 ,2 ]
Kielar, Filip [3 ]
Hadsadee, Sarinya [4 ,5 ]
Jungsuttiwong, Siriporn [4 ,5 ]
Youngme, Sujittra [1 ,2 ]
机构
[1] Khon Kaen Univ, Fac Sci, Mat Chem Res Ctr, Dept Chem, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Fac Sci, Ctr Excellence Innovat Chem, Khon Kaen 40002, Thailand
[3] Naresuan Univ, Dept Chem, Phitsanulok 65000, Thailand
[4] Ubon Ratchathani Univ, Fac Sci, Ctr Organ Elect & Alternat Energy, Dept Chem, Ubon Ratchathani 34190, Thailand
[5] Ubon Ratchathani Univ, Fac Sci, Ctr Excellence Innovat Chem, Ubon Ratchathani 34190, Thailand
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2020年 / 316卷 / 316期
关键词
Metal-organic framework; Self-calibration; Anthrax biomarker; Logic gate operation; METAL-ORGANIC FRAMEWORKS; RATIOMETRIC FLUORESCENT DETECTION; SENSITIVE DETECTION; QUANTUM DOTS; CARBON DOTS; LUMINESCENT; PROBE; NANOPARTICLES; LIGHT; SHELL;
D O I
10.1016/j.snb.2020.128156
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The bacillus anthracis is one of toxic bacterial spores that can cause human anthrax infections. In this effort, the nanoscaled bimetallic lanthanoid metal-organic framework (Ln-MOF), namely, [Tb0.43Eu1.57(1,4-phda)(3)(H2O)] (H2O)(2) was synthesized by tuning the mole ratio of Tb3+ and Eu3+ as a ratiometric luminescent sensor for anthrax biomarker (dipicolinic acid, DPA). The detection limits of this DPA sensor are as low as 5.9 nM in methanol and 0.17 mu M in water which are lower than human infectious doses. This sensor can detect DPA via turn-on process with broad ranges at either low concentration (0-800 nM) in methanol or high concentration (20-100 mu M) in an aqueous medium. Moreover, the bimetallic Ln-MOF's emission colors in the presence of DPA are changed from red-orange to orange-yellow in methanol, and red-orange to green in water that can be easily seen in solution and film by naked-eyes. In addition, one-to-two logic gate operation for monitoring DPA concentration levels of this sensor has been developed. The luminescent probe is also applied for DPA detection in real tap-water and urine samples with good performances.
引用
收藏
页数:9
相关论文
共 43 条
  • [1] Tb(Ⅲ) functionalized MOF based self-calibrating sensor integrated with logic gate operation for efficient epinephrine detection in serum
    Dongsheng Zhao
    Wenqian Li
    Rongmei Wen
    Wencui Li
    Xin Liu
    Xiutang Zhang
    Liming Fan
    Journal of Rare Earths, 2024, 42 (05) : 987 - 994
  • [2] Tb(III) functionalized MOF based self-calibrating sensor integrated with logic gate operation for efficient epinephrine detection in serum
    Zhao, Dongsheng
    Li, Wenqian
    Wen, Rongmei
    Li, Wencui
    Liu, Xin
    Zhang, Xiutang
    Fan, Liming
    JOURNAL OF RARE EARTHS, 2024, 42 (05) : 987 - 994
  • [3] A self-calibrating bimetallic lanthanide metal-organic luminescent sensor integrated with logic gate operation for detecting N-methylformamide
    Qin, Si-Jia
    Qu, Xiang-Long
    Yan, Bing
    INORGANIC CHEMISTRY FRONTIERS, 2018, 5 (11): : 2971 - 2977
  • [4] A Novel Tb@Sr-MOF as Self-Calibrating Luminescent Sensor for Nutritional Antioxidant
    Wang, Yi
    Lin, Shaomin
    Luo, Jun
    Huang, Rui
    Cai, Hong
    Yan, Wei
    Yang, Huan
    NANOMATERIALS, 2018, 8 (10):
  • [5] A new bimetallic lanthanide metal-organic framework as a self-calibrating sensor for formaldehyde
    Wang, Yi
    Wu, Yunying
    Zhou, Chanyuan
    Cao, Liming
    Yang, Huan
    INORGANIC CHEMISTRY COMMUNICATIONS, 2018, 89 : 5 - 9
  • [6] Eu(III) functionalized ZnMOF based efficient dual-emission sensor integrated with self-calibrating logic gate for intelligent detection of epinephrine
    Zhao, Dongsheng
    Li, Wencui
    Li, Wenqian
    Liu, Xin
    Yang, Jingyao
    Lu, Feiyu
    Zhang, Xiutang
    Fan, Liming
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 315
  • [7] RhB-encapsulated MOF-based composite as self-calibrating sensor for selective detection of 4-nitroaniline
    Sun, Zhenyu
    Li, Jiangying
    Wang, Xiaoqing
    Zhao, Zhongrui
    Lv, Rongbao
    Zhang, Qi
    Wang, Fengqin
    Zhao, Yongnan
    JOURNAL OF LUMINESCENCE, 2022, 241
  • [8] Self-Calibrating Body Sensor Network Based on Periodic Human Movements
    Sabti, Haider Abd Ali
    Thiel, David Victor
    IEEE SENSORS JOURNAL, 2015, 15 (03) : 1552 - 1558
  • [9] Compact low-voltage self-calibrating digital floating-gate CMOS logic circuits
    Ytterdal, T
    Aunet, S
    2002 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL V, PROCEEDINGS, 2002, : 393 - 396
  • [10] A built-in self-calibrating luminescence sensor based on RhB@Zr-MOF for detection of cations, nitro explosives and pesticides
    Yang, Liu
    Liu, Yu-Long
    Liu, Cheng-Guo
    Fu, Ying
    Ye, Fei
    RSC ADVANCES, 2020, 10 (33) : 19149 - 19156