Self-calibrating sensor with logic gate operation for anthrax biomarker based on nanoscaled bimetallic lanthanoid MOF

被引:74
|
作者
Othong, Jintana [1 ,2 ]
Boonmak, Jaursup [1 ,2 ]
Kielar, Filip [3 ]
Hadsadee, Sarinya [4 ,5 ]
Jungsuttiwong, Siriporn [4 ,5 ]
Youngme, Sujittra [1 ,2 ]
机构
[1] Khon Kaen Univ, Fac Sci, Mat Chem Res Ctr, Dept Chem, Khon Kaen 40002, Thailand
[2] Khon Kaen Univ, Fac Sci, Ctr Excellence Innovat Chem, Khon Kaen 40002, Thailand
[3] Naresuan Univ, Dept Chem, Phitsanulok 65000, Thailand
[4] Ubon Ratchathani Univ, Fac Sci, Ctr Organ Elect & Alternat Energy, Dept Chem, Ubon Ratchathani 34190, Thailand
[5] Ubon Ratchathani Univ, Fac Sci, Ctr Excellence Innovat Chem, Ubon Ratchathani 34190, Thailand
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2020年 / 316卷 / 316期
关键词
Metal-organic framework; Self-calibration; Anthrax biomarker; Logic gate operation; METAL-ORGANIC FRAMEWORKS; RATIOMETRIC FLUORESCENT DETECTION; SENSITIVE DETECTION; QUANTUM DOTS; CARBON DOTS; LUMINESCENT; PROBE; NANOPARTICLES; LIGHT; SHELL;
D O I
10.1016/j.snb.2020.128156
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The bacillus anthracis is one of toxic bacterial spores that can cause human anthrax infections. In this effort, the nanoscaled bimetallic lanthanoid metal-organic framework (Ln-MOF), namely, [Tb0.43Eu1.57(1,4-phda)(3)(H2O)] (H2O)(2) was synthesized by tuning the mole ratio of Tb3+ and Eu3+ as a ratiometric luminescent sensor for anthrax biomarker (dipicolinic acid, DPA). The detection limits of this DPA sensor are as low as 5.9 nM in methanol and 0.17 mu M in water which are lower than human infectious doses. This sensor can detect DPA via turn-on process with broad ranges at either low concentration (0-800 nM) in methanol or high concentration (20-100 mu M) in an aqueous medium. Moreover, the bimetallic Ln-MOF's emission colors in the presence of DPA are changed from red-orange to orange-yellow in methanol, and red-orange to green in water that can be easily seen in solution and film by naked-eyes. In addition, one-to-two logic gate operation for monitoring DPA concentration levels of this sensor has been developed. The luminescent probe is also applied for DPA detection in real tap-water and urine samples with good performances.
引用
收藏
页数:9
相关论文
共 43 条
  • [31] Room-temperature self-calibrating sensor based on CsPbBr3/SnO2 for detecting low-concentration sulfur dioxide
    Chen, Lu
    Gao, Shasha
    Cheng, Yongchao
    Wang, Peng
    Huang, Sheng
    Journal of Alloys and Compounds, 1600, 1009
  • [32] A quantitative ratiometric fluorescent Hddb-based MOF sensor and its on-site detection of the anthrax biomarker 2,6-dipicolinic acid
    Chen, Xuan-Bo
    Qi, Cui-Xing
    Xu, Yu-Bin
    Li, Hong
    Xu, Ling
    Liu, Bing
    JOURNAL OF MATERIALS CHEMISTRY C, 2020, 8 (48) : 17325 - 17335
  • [33] Real-Time Self-Calibrating Phase-Shifted Demodulation Method Based on Polarized Low-Coherence Interference for Optical Fiber Acoustic Sensor
    Yang, Haokun
    Wang, Shuang
    Liu, Kun
    Jiang, Junfeng
    Li, Yuqing
    Li, Zhiyuan
    Zhang, Peng
    Dai, Xiaoshuang
    Liu, Tiegen
    IEEE SENSORS JOURNAL, 2022, 22 (09) : 8537 - 8543
  • [34] Eu3+-MOF fluorescence sensor based on a dual-ligand strategy for visualised detection of an anthrax biomarker 2,6-pyridine dicarboxylic acid
    Wang, Runnan
    Zhang, Hao
    Sun, Jing
    Su, Zhongmin
    INORGANIC CHEMISTRY FRONTIERS, 2023, 11 (01) : 269 - 277
  • [35] The fabrication of fluorescent sensor for Fe3+detection and configurable logic gate operation based on N-doped carbon dots
    Zhao, Yanan
    Ji, Xinxin
    Liang, Jiamin
    Gao, Yue
    Xing, Huan
    Song, Yuxin
    Hou, Juan
    Yang, Guang
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2024, 449
  • [36] A naphthalenecarboxamide based fluorescent sensor for selective detection of Fe3+and CN?: Live cell imaging and INHIBIT logic gate operation
    Tavakoli, Behnam
    Meghdadi, Soraia
    Salarvand, Zohreh
    Eskandari, Kiamars
    Amiri, Ahmad
    Amirnasr, Mehdi
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2023, 440
  • [37] A non-luminescent Eu-MOF-based "turn-on" sensor towards an anthrax biomarker through single-crystal to single-crystal phase transition
    Wu, Dai
    Zhang, Zhe
    Chen, Xiwen
    Meng, Lingkun
    Li, Chunguang
    Li, Guanghua
    Chen, Xiaobo
    Shi, Zhan
    Feng, Shouhua
    CHEMICAL COMMUNICATIONS, 2019, 55 (99) : 14918 - 14921
  • [38] A multi-ratiometric fluorescence sensor integrated intrinsic signal amplification strategy for a sensitive and visual assay of the anthrax biomarker based on a bimetallic lanthanide metal-organic framework
    Han, Lei
    Dong, Xue Zhen
    Liu, Shi Gang
    Wang, Xiao Hu
    Ling, Yu
    Li, Nian Bing
    Luo, Hong Qun
    ENVIRONMENTAL SCIENCE-NANO, 2023, 10 (02) : 683 - 693
  • [39] A 130-nm CMOS 0.007-mm2 Ring-Oscillator-Based Self-Calibrating IR-UWB Transmitter Using an Asynchronous Logic Duty-Cycled PLL
    Crepaldi, Marco
    Demarchi, Danilo
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2013, 60 (05) : 237 - 241
  • [40] Continuous response fluorescence sensor for three small molecules based on nitrogen-doped carbon quantum dots from prunus lannesiana and their logic gate operation
    Guo, Zicheng
    Liu, Xuerui
    Yu, Haiyu
    Hou, Faju
    Gao, Shanmin
    Zhong, Linlin
    Xu, Hui
    Yu, Yang
    Meng, Junli
    Wang, Ruru
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 257