Implantation of a Fully Subcutaneous ICD in Children

被引:11
|
作者
McLeod, Karen A. [1 ]
McLean, Andrew [1 ]
机构
[1] Royal Hosp Sick Children, Glasgow G3 8SJ, Lanark, Scotland
来源
关键词
defibrillationuICD; pediatrics; CARDIOVERTER; COMPLICATIONS;
D O I
10.1111/j.1540-8159.2010.02865.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The subcutaneous implantable cardioverter defibrillator (S-ICD) from Cameron Health (San Clemente, CA, USA) does not require a lead to be placed on or in the heart. Such a device, being subcutaneous, has potential benefits in children who require ICDs where problems largely relate to transvenous or epicardial leads and inappropriate shocks. The S-ICD was approved for use in Europe in June 2009 and recently a study commenced to acquire data in 330 patients in order to submit to the FDA. We shall describe the implantation of the S-ICD in two children aged 10 and 12 years at our institution. (PACE 2012; 35:e20e23)
引用
收藏
页码:e20 / e23
页数:4
相关论文
共 50 条
  • [41] Prognosis after ICD implantation
    Conti, CR
    CLINICAL CARDIOLOGY, 2001, 24 (11) : 699 - 699
  • [42] Subcutaneous ICD in anatomical challenging cases
    Kuschyk, J.
    Roeger, S.
    Fastner, C.
    Behnes, M.
    Akin, I.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2015, 19 (17) : 3140 - 3141
  • [43] Current Device Therapies for Sudden Cardiac Death Prevention - the ICD, Subcutaneous ICD and Wearable ICD
    Chieng, David
    Paul, Vince
    Denman, Russell
    HEART LUNG AND CIRCULATION, 2019, 28 (01): : 65 - 75
  • [44] Follow-up of the first patients with a totally subcutaneous ICD in Germany from implantation till battery depletion
    Markus Bettin
    Benjamin Rath
    Christian Ellermann
    Patrick Leitz
    Florian Reinke
    Julia Köbe
    Lars Eckardt
    Gerrit Frommeyer
    Clinical Research in Cardiology, 2019, 108 : 16 - 21
  • [45] A RARE COMPLICATION OF ICD IMPLANTATION: LEFT SIDED ICD LEAD
    Arikan, Erdinc Mehmet
    Vurgun, Kutay
    Yesil, Murat
    Bayata, Serdar
    Postaci, Nursen
    Tuluce, Selcen Yakar
    Avci, Eyup
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 : S87 - S87
  • [46] Follow-up of the first patients with a totally subcutaneous ICD in Germany from implantation till battery depletion
    Bettin, Markus
    Rath, Benjamin
    Ellermann, Christian
    Leitz, Patrick
    Reinke, Florian
    Koebe, Julia
    Eckardt, Lars
    Frommeyer, Gerrit
    CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (01) : 16 - 21
  • [47] Incidence of very high defibrillation thresholds (DFT) and efficacy of subcutaneous array insertion during defibrillator (ICD) implantation
    Verma, A.
    Higenbottom, J.
    Wulffhart, Z.
    Beardsall, M.
    Patterson, S.
    Khaykin, Y.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 207C - 207C
  • [48] A manual synchronous low energy shock impedance as a predictor of successful defibrillation testing during subcutaneous ICD implantation
    Calvo, Naiara
    Lopez-Perales, Carlos Ruben
    Oloriz, Teresa
    Diaz-Cortegana, Francisco
    Jauregui, Beatriz
    Soto, Nina
    Rodriguez, Pilar
    Santamaria, Eva
    Ortas, M. Rosario
    Asso, Antonio
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (09): : 1185 - 1191
  • [49] SUBCUTANEOUS SCROTAL IMPLANTATION
    LOOSEMORE, TGE
    BRITISH MEDICAL JOURNAL, 1956, 1 (JUN9): : 1367 - 1367