Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer

被引:69
|
作者
Savini, Giacomo [1 ]
Hoffer, Kenneth J. [4 ,5 ]
Balducci, Nicole [1 ]
Barboni, Piero [2 ,3 ]
Schiano-Lomoriello, Domenico [1 ]
机构
[1] IRCCS GB Bietti Fdn, Via Livenza 3, Rome, Italy
[2] Studio Oculist Azeglio, Bologna, Italy
[3] Osped San Raffaele, Milan, Italy
[4] Univ Calif Los Angeles, Stein Eye Inst, Los Angeles, CA USA
[5] St Marys Eye Ctr, Santa Monica, CA USA
来源
关键词
SYSTEM;
D O I
10.1016/j.jcrs.2019.08.044
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the results of intraocular lens (IOL) power calculation using measurements by a swept-source optical coherence tomography (SS-OCT) optical biometer. Setting: IRCCS G.B. Bietti Foundation, Rome, Italy. Design: Evaluation of a diagnostic test instrument. Methods: Preoperative measurements by the OA-2000 (Tomey Inc.) were taken in a consecutive series of patients undergoing cataract surgery with one IOL model (AcrySof SN60WF; Alcon Laboratories, Inc.). Measurements were entered into the following formulas: Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Hoffer Q, Holladay 1, Holladay 2, Holladay 2 with axial length adjustment, Kane, Olsen, Panacea, SRIVT, T2, and VRF. When refraction was measured at 1 month postoperatively, the mean arithmetic prediction error, the median absolute error (MedAE), and the percentage of eyes with a error of +/- 0.50 D or less were calculated after constant optimization. Results: We enrolled 150 eyes. All formulas yielded excellent outcomes. The MedAE ranged between 0.200 D and 0.259 D, with a statistically significant difference among formulas (P = .0004). The lowest MedAE values were obtained with the Barrett, EVO, Kane, Olsen(standalone), Radial Basis Function (RBF), and T2 formulas. The percentage of eyes with a prediction error of +/- 0.50 D or less ranged between 80.00% and 90.67%, with a statistically significant difference (P < .0001). The Barrett, EVO, Holladay 2 with axial length adjustment, Kane, RBF, and T2 achieved the highest percentages (>= 88%). Conclusions: Measurements provided by the SS-OCT optical biometer enable accurate IOL power calculation because all formulas yielded a prediction error within 0.50 D in at least 80% of eyes. Copyright (C) 2019 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:27 / 33
页数:7
相关论文
共 50 条
  • [31] Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
    Tommy C. Y. Chan
    Marco C. Y. Yu
    Vivian Chiu
    Gilda Lai
    Christopher K. S. Leung
    Poemen P. M. Chan
    Scientific Reports, 11
  • [32] Biometry and intraocular power calculation using a swept-source optical coherence tomography: A repeatability and agreement study
    Hashemi, Hassan
    Miraftab, Mohammad
    Panahi, Parsa
    Asgari, Soheila
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2845 - 2850
  • [33] Evaluation of Refractive Predictive Accuracy in Intraocular Lens Power Calculations: A Comparative Study of Swept-Source Optical Coherence Tomography and Optical Low-Coherence Interferometry
    Al Barri, Leila
    Mercea, Nadina
    Ionela-Iasmina, Yasar
    Munteanu, Mihnea
    Stanca, Horia T.
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [34] Comparison of a New Optical Biometer That Combines Scheimpflug Imaging With Partial Coherence Interferometry With That of an Optical Biometer Based on Swept-Source Optical Coherence Tomography and Placido-Disk Topography
    Chen, Shihao
    Zhang, Qiaoyue
    Savini, Giacomo
    Zhang, Shuangzhe
    Huang, Xiaomin
    Yu, Jinjin
    Wang, Yirang
    Ning, Rui
    Huang, Jinhai
    Tu, Ruixue
    FRONTIERS IN MEDICINE, 2022, 8
  • [35] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Dominguez-Vicent, Alberto
    Venkataraman, Abinaya Priya
    Dalin, Amanda
    Brautaset, Rune
    Montes-Mico, Robert
    EYE AND VISION, 2023, 10 (01)
  • [36] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Alberto Domínguez-Vicent
    Abinaya Priya Venkataraman
    Amanda Dalin
    Rune Brautaset
    Robert Montés-Micó
    Eye and Vision, 10
  • [37] Impact of lens opacity and axial length on concomitant screening of maculopathy by swept-source optical coherence tomography-based optical biometer
    Qin, Yingyan
    Ye, Shaobi
    Liu, Liangping
    Wu, Mingxing
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (15)
  • [38] An Intraocular Lens Power Calculation Formula Based on Optical Coherence Tomography: A Pilot Study
    Tang, Maolong
    Li, Yan
    Huang, David
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (06) : 430 - 437
  • [39] Crystalline lens power and astigmatism calculation in myopia by swept-source optical coherence tomography: A pilot study
    Wang, Shulin
    Cheng, Dan
    Zhu, Xueying
    Bao, Fangjun
    Zhu, Jun
    Pang, Chenjiu
    Ye, Yufeng
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [40] Assessment of precision of astigmatism measurements taken by a swept-source optical coherence tomography biometer - IOLMaster 700
    Sharma, Ajay
    Batra, Akanksha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (07) : 1760 - 1765