A novel comparative photothermal method for measuring thermal diffusivity

被引:2
|
作者
Broussely, M [1 ]
Levick, AP [1 ]
Edwards, GJ [1 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
comparative method; laser absorption radiation thermometry (LART); laser; photothermal radiometry; thermal diffusivity;
D O I
10.1007/s10765-005-2370-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel comparative method has been developed at the National Physical Laboratory (NPL) to measure the thermal diffusivity of semi-infinite samples without a priori knowledge of the boundary conditions. It is based on photothermal radiometry, and involves the detection of modulated thermal radiance from a target irradiated by a modulated. focused diode laser beam with a power of 1 W. The technique exploits the fact that the frequency response of the surface temperature modulation scales with thermal diffusivity for a given target geometry (this is a fundamental property of the heat diffusion equation). In the process two samples are measured, one of which is known, and the diffusivity of the second material is derived from scaling the results over frequency. Measurements on samples of platinum and Inconel have shown the validity of the methodology but also raised issues concerning the difficulty of accurate measurements due to surface coatings or roughness.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 50 条
  • [41] TEST MEASUREMENTS OF THE PHOTOTHERMAL DEFLECTION METHOD TO DETERMINE THE THERMAL-DIFFUSIVITY OF SOLIDS
    SUBER, G
    BERTOLOTTI, M
    SIBILIA, C
    FERRARI, A
    APPLIED OPTICS, 1988, 27 (09): : 1807 - 1810
  • [42] A cryostatic setup for the low-temperature measurement of thermal diffusivity with the photothermal method
    Bertolotti, M
    Liakhou, G
    Voti, RL
    Paoloni, S
    Sibilia, C
    Sparvieri, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (12): : 5598 - 5602
  • [43] Automated apparatus, for measuring the thermal diffusivity of metals by the thermal-wave method
    Korobov, AI
    Odina, NI
    Kokshaiskii, IN
    Zhdanova, NV
    MEASUREMENT TECHNIQUES, 1996, 39 (04) : 423 - 428
  • [44] New contactless method for thermal diffusivity measurements using modulated photothermal radiometry
    Quoc, S. Pham Tu
    Cheymol, G.
    Semerok, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (05):
  • [45] Thermal diffusivity measurement using the mode-mismatched photothermal lens method
    Benitez, Miguel
    Marcano, Aristides
    Melikechi, Noureddine
    OPTICAL ENGINEERING, 2009, 48 (04)
  • [46] Cryostatic setup for the low-temperature measurement of thermal diffusivity with the photothermal method
    Bertolotti, M., 1600, American Inst of Physics, Woodbury, NY, United States (66):
  • [47] Measurement of thermal diffusivity/thermal contact resistance using laser photothermal method at cryogenic temperatures
    Bi Dongmei
    Chen Huanxin
    Liu Shanjian
    Shen Limei
    APPLIED THERMAL ENGINEERING, 2017, 111 : 768 - 775
  • [48] The theoretical study of the measuring thermal diffusivity of semi-infinite solid using the photothermal displacement
    Pilsoo Jeon
    Kwangjai Lee
    Jaisuk Yoo
    Youngmoo Park
    Jonghwa Lee
    KSME International Journal, 2004, 18 : 1712 - 1721
  • [49] The theoretical study of the measuring thermal diffusivity of semi-infinite solid using the photothermal displacement
    Jeon, P
    Lee, K
    Yoo, J
    Park, Y
    Lee, J
    KSME INTERNATIONAL JOURNAL, 2004, 18 (10): : 1712 - 1721
  • [50] PUMP-PROBE PHOTOTHERMAL LENS EXPERIMENT FOR MEASURING THE THERMAL DIFFUSIVITY COEFFICIENT OF ORGANIC SOLVENTS
    Marcano, A.
    Melikechi, O. N.
    Zelinskas, A.
    Benitez, M.
    LINEAR AND NONLINEAR OPTICS OF ORGANIC MATERIALS VIII, 2008, 7049