Side Lobe Reduction Using Centroid and Flatness in Passive Cavitation Imaging

被引:0
|
作者
Jeong, Mok Kun [1 ]
Kwon, Sung Jae [2 ]
Choi, Min Joo [3 ]
机构
[1] Daejin Univ, Dept Elect Engn, Pochon, South Korea
[2] Daejin Univ, Div Human IT Convergence Engn, Pochon, South Korea
[3] Jeju Natl Univ, Sch Med, Dept Med, Jeju, South Korea
关键词
centroid; flatness; passive cavitation imaging; ultrasound; weighting;
D O I
10.1109/ultsym.2019.8925582
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cavitation bubbles generated by high-intensity focused ultrasound strongly collapse and emit ultrasound waves. Since passive cavitation imaging can be performed using only receive focusing, side lobes appear over a wide area of an image. The delay and sum beamforming technique used to construct passive cavitation images cannot effectively image the cavitation occurrence time and spatial distribution because a small cavitation signal is buried in the side lobe of a large cavitation signal when there are a large number of cavitation bubbles. The ultrasound wave emitted when the cavitation bubble collapses is a short duration pulse. After compensating for the focusing delay, the signals due to the main lobe (at the imaging point) received at each element of the transducer array are similar in magnitude, but those due to the side lobes (other than the imaging point) is significant only at some elements of the array. Using this characteristic of the received channel data, we propose both centroid and flatness as metrics to evaluate the effect of the main and side lobes at imaging points. If the centroid of the signal magnitude distribution of the entire receiving channel is positioned at the center of the array, the signal is considered to be due to the main lobe. However, if the centroid is computed to be located near both ends of the array, the signal is considered to be due to the side lobes. If the signals are found to be due to the side lobes in passive cavitation imaging, the pixel brightness is reduced by weighting using the centroid and flatness metrics. We computed the centroid and flatness metrics using computer simulation and experimental data, and confirmed the suppression of side lobes by multiplying the image by a weight using the centroid and flatness. The proposed method makes it easier to observe cavitation by effectively removing side lobes from passive cavitation images when the number of cavitation bubbles is not large.
引用
收藏
页码:1455 / 1458
页数:4
相关论文
共 50 条
  • [41] An optimum side-lobe reduction method with weight perturbation
    Mohammed, Jafar Ramadhan
    JOURNAL OF COMPUTATIONAL ELECTRONICS, 2019, 18 (02) : 705 - 711
  • [42] Reduction of cavitation using pseudorandom signals
    INSERM, Lyon, France
    IEEE Trans Ultrason Ferroelectr Freq Control, 4 (623-625):
  • [43] Reduction of cavitation using pseudorandom signals
    Chapelon, JY
    Dupenloup, F
    Cohen, H
    Lenz, P
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (04) : 623 - 625
  • [44] An optimum side-lobe reduction method with weight perturbation
    Jafar Ramadhan Mohammed
    Journal of Computational Electronics, 2019, 18 : 705 - 711
  • [45] Particle Swarm Optimization for Side Lobe Reduction of Antenna Array
    Xue, Li
    Zhang, Jiao
    Pan, Yusheng
    Liu, Yufeng
    2019 CROSS STRAIT QUAD-REGIONAL RADIO SCIENCE AND WIRELESS TECHNOLOGY CONFERENCE (CSQRWC), 2019,
  • [46] Invasive weed optimization for side lobe reduction in antenna array
    Satrusallya, Sarmistha
    Mahapatra, Shaktijeet
    JOURNAL OF INFORMATION & OPTIMIZATION SCIENCES, 2022, 43 (05): : 1121 - 1129
  • [47] Side Lobe Level Reduction for Beam Steerable Antenna Design
    Allayioti, Marion
    Kelly, James R.
    2016 10TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2016,
  • [48] A Side lobe Level Reduction (SLL) for Planar Array Antennas
    Aboul-Seoud, Ahmed Khairy
    Mahmoud, Ahmed Khairy
    Hafez, Alaa
    NRSC: 2009 NATIONAL RADIO SCIENCE CONFERENCE: NRSC 2009, VOLS 1 AND 2, 2009, : 412 - 419
  • [49] Flash echo (passive cavitation) imaging of the liver by using US contrast agents and intermittent scanning sequence
    Moriyasu, F
    Kono, Y
    Nada, T
    Matsumura, T
    Suginoshita, V
    Kobayashi, K
    RADIOLOGY, 1996, 201 : 374 - 374
  • [50] Suppression of side lobe using spectral weights of channel data in medical ultrasonic imaging system
    Lee, Yu Rim
    Jeong, Mok Kun
    2024 IEEE UFFC LATIN AMERICA ULTRASONICS SYMPOSIUM, LAUS, 2024,