Side Lobe Reduction Using Centroid and Flatness in Passive Cavitation Imaging

被引:0
|
作者
Jeong, Mok Kun [1 ]
Kwon, Sung Jae [2 ]
Choi, Min Joo [3 ]
机构
[1] Daejin Univ, Dept Elect Engn, Pochon, South Korea
[2] Daejin Univ, Div Human IT Convergence Engn, Pochon, South Korea
[3] Jeju Natl Univ, Sch Med, Dept Med, Jeju, South Korea
关键词
centroid; flatness; passive cavitation imaging; ultrasound; weighting;
D O I
10.1109/ultsym.2019.8925582
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cavitation bubbles generated by high-intensity focused ultrasound strongly collapse and emit ultrasound waves. Since passive cavitation imaging can be performed using only receive focusing, side lobes appear over a wide area of an image. The delay and sum beamforming technique used to construct passive cavitation images cannot effectively image the cavitation occurrence time and spatial distribution because a small cavitation signal is buried in the side lobe of a large cavitation signal when there are a large number of cavitation bubbles. The ultrasound wave emitted when the cavitation bubble collapses is a short duration pulse. After compensating for the focusing delay, the signals due to the main lobe (at the imaging point) received at each element of the transducer array are similar in magnitude, but those due to the side lobes (other than the imaging point) is significant only at some elements of the array. Using this characteristic of the received channel data, we propose both centroid and flatness as metrics to evaluate the effect of the main and side lobes at imaging points. If the centroid of the signal magnitude distribution of the entire receiving channel is positioned at the center of the array, the signal is considered to be due to the main lobe. However, if the centroid is computed to be located near both ends of the array, the signal is considered to be due to the side lobes. If the signals are found to be due to the side lobes in passive cavitation imaging, the pixel brightness is reduced by weighting using the centroid and flatness metrics. We computed the centroid and flatness metrics using computer simulation and experimental data, and confirmed the suppression of side lobes by multiplying the image by a weight using the centroid and flatness. The proposed method makes it easier to observe cavitation by effectively removing side lobes from passive cavitation images when the number of cavitation bubbles is not large.
引用
收藏
页码:1455 / 1458
页数:4
相关论文
共 50 条
  • [21] Frequency-sum beamforming for passive cavitation imaging
    Abadi, Shima H.
    Haworth, Kevin J.
    Mercado-Shekhar, Karla P.
    Dowling, David R.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 144 (01): : 198 - 209
  • [22] Side lobe reduction in vivaldi array radiation pattern using genetic agorithm and FDTD
    Barari, M.
    Tavakoli, A.
    Moini, R.
    Amirkabir (Journal of Science and Technology), 2003, 14 (56 A): : 233 - 238
  • [23] Design of linear antenna arrays for side lobe reduction using the tabu search method
    Merad, Lotfi
    Bendimerad, Fethi
    Meriah, Sidi
    INTERNATIONAL ARAB JOURNAL OF INFORMATION TECHNOLOGY, 2008, 5 (03) : 219 - 222
  • [24] Multiplexed ultrasound beam summation for side lobe reduction
    Ilovitsh, Asaf
    Ilovitsh, Tali
    Ferrara, Katherine W.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [25] Side Lobe Reduction in Uniformly Excited Linear Arrays
    Safaai-Jazi, Ahmad
    Stutzman, Warren L.
    2015 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2015, : 2449 - 2450
  • [26] Multiplexed ultrasound beam summation for side lobe reduction
    Asaf Ilovitsh
    Tali Ilovitsh
    Katherine W. Ferrara
    Scientific Reports, 9
  • [27] Side lobe level reduction of metasurface transmit array
    Kumar, Vinod P.
    Ghosh, Basudeb
    ENGINEERING RESEARCH EXPRESS, 2022, 4 (03):
  • [28] Artifact Suppression for Passive Cavitation Imaging Using U-Net CNNs with Uncertainty Quantification
    Liu, Yushi
    Tracey, Brian
    Aeron, Shuchin
    Miller, Eric
    Sun, Tao
    McDannold, Nathan
    Murphy, James
    2019 IEEE 4TH INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING (ICSIP 2019), 2019, : 1037 - 1042
  • [29] 3D Passive Imaging of Ultrasound Cavitation using a 2D Array
    Boulos, Paul
    Varray, Francois
    Gilles, Bruno
    Bera, Jean-Christophe
    Cachard, Christian
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [30] Advanced beamforming techniques for passive imaging of stable and inertial cavitation
    Polichetti, Maxime
    Varray, Francois
    Bera, Jean-Christophe
    Cachard, Christian
    Nicolas, Barbara
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,