Modeling and performance study of a water-injected twin-screw water vapor compressor

被引:35
|
作者
Tian, Yafen [1 ]
Shen, Jiubing [1 ,2 ]
Wang, Chuang [1 ]
Xing, Ziwen [1 ]
Wang, Xiaolin [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] Jiangsu Univ Sci & Technol, Sch Energy & Power Engn, 2 Mengxi Rd, Zhenjiang 212003, Peoples R China
[3] Univ Tasmania, Sch Engn & ICT, Hobart, Tas 7001, Australia
基金
中国国家自然科学基金;
关键词
MVC system; Water injection; Twin screw compressor; p-V indicator diagram; Performance study; HEAT-PUMP; REFRIGERATION COMPRESSOR; WORKING PROCESS; DISTILLATION; RECOMPRESSION; SIMULATION; CYCLE; MVC;
D O I
10.1016/j.ijrefrig.2017.04.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Due to the reason of water injection, twin screw water vapor compressor can realize higher pressure ratio and saturated temperature lift of compressed vapor. Its application in mechanical vapor compression (MVC) heat pump systems has drawn much attention recently because of the great energy-saving potential and reliability. In this paper, a thermodynamic model of the working process in water injected twin screw water vapor compressor is established, in which heat and mass transfer between water liquid and vapor are considered. Its accuracy is validated by the experimental recorded p-V indicator diagrams. With the proposed model, the compressor performance is simulated and studied. According to the simulation results, water injection can increase the volumetric efficiency 5% and adiabatic indication efficiency 6%. Once the discharged vapor has been cooled to saturation, the shaft power of the compressor will increase while the adiabatic indication efficiency and the volume flow rate together with the volumetric efficiency change little with the continuous increase of injected water. Since the sensible heat of water is much smaller than latent heat, the temperature of injectedwater has little effect on the performance. Both the volume flowrate and shaft power increase linearly with the rotor speed. In addition, the volume flowrate of injectedwater should be adjusted with the regulation of rotor speed to guarantee a saturate discharge temperature. The volumetric efficiency will increase and the adiabatic indication efficiency will decrease slowly with the rise of rotor speed. Due to the cooling and evaporation effects of liquid water at the discharge chamber, the adiabatic indication efficiency does not decline when it operates at under compression condition. Water injection can greatly improve the compressor performance when the compressor operates at under compression or over compression condition, especially where a high saturated temperature lift of compressed vapor is in demand. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:75 / 87
页数:13
相关论文
共 50 条
  • [41] Screw optimization for performance enhancement of a twin-screw pump
    Tang, Qian
    Zhang, Yuanxun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2014, 228 (01) : 73 - 84
  • [42] MODELING PERFORMANCE-CHARACTERISTICS OF COUNTERROTATING, TANGENTIAL TWIN-SCREW EXTRUDERS
    NICHOLS, RJ
    PLASTICS ENGINEERING, 1984, 40 (03) : 27 - 27
  • [43] The design of a twin-screw compressor based on a new rotor profile
    Stosic, N
    Smith, IK
    Kovacevic, A
    Aldis, CA
    JOURNAL OF ENGINEERING DESIGN, 1997, 8 (04) : 389 - 399
  • [44] An experimental technique to simulate and measure leakages in twin-screw compressor
    Patel, Hitesh H.
    Lakhera, Vikas J.
    ENGINEERING RESEARCH EXPRESS, 2021, 3 (01):
  • [45] Precision Grinding Process Design of Twin-screw Compressor Rotor
    Zhao, Yongqiang
    Zhao, Shengdun
    Hou, Hongling
    ADVANCED TECHNOLOGIES IN MANUFACTURING, ENGINEERING AND MATERIALS, PTS 1-3, 2013, 774-776 : 1107 - +
  • [46] Research on power consumption distribution characteristics of a water-lubricated twin-screw air compressor for fuel cell applications
    Wang, Chuang
    Liu, Mingkun
    Wang, Bingqi
    Xing, Ziwen
    Shu, Yue
    ENERGY, 2022, 256
  • [47] Experimental Investigation on the Effect of Water Cooling on a Dry Twin-Screw Air Compressor for Proton Exchange Membrane Fuel Cells
    Liu, Mingkun
    Wang, Chuang
    Li, Yanpeng
    Li, Yuchen
    Liu, Lixin
    Xing, Ziwen
    APPLIED SCIENCES-BASEL, 2024, 14 (06):
  • [48] Twin-screw pump for an oil-water-gas multiphase liquid
    V. M. Ryazantsev
    V. V. Likhman
    V. A. Yakhontov
    Chemical and Petroleum Engineering, 2000, 36 : 432 - 436
  • [49] Experimental study of lubricating oil impact on pressure pulsation for twin-screw refrigeration compressor
    Yang, Shengmei
    Ouyang, Hua
    Wu, Yadong
    Wang, Lee
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 112 : 324 - 332
  • [50] Twin-screw pump for an oil-water-gas multiphase liquid
    Ryazantsev, VM
    Likhman, VV
    Yakhontov, VA
    CHEMICAL AND PETROLEUM ENGINEERING, 2000, 36 (7-8) : 432 - 436