Modeling and performance study of a water-injected twin-screw water vapor compressor

被引:35
|
作者
Tian, Yafen [1 ]
Shen, Jiubing [1 ,2 ]
Wang, Chuang [1 ]
Xing, Ziwen [1 ]
Wang, Xiaolin [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] Jiangsu Univ Sci & Technol, Sch Energy & Power Engn, 2 Mengxi Rd, Zhenjiang 212003, Peoples R China
[3] Univ Tasmania, Sch Engn & ICT, Hobart, Tas 7001, Australia
基金
中国国家自然科学基金;
关键词
MVC system; Water injection; Twin screw compressor; p-V indicator diagram; Performance study; HEAT-PUMP; REFRIGERATION COMPRESSOR; WORKING PROCESS; DISTILLATION; RECOMPRESSION; SIMULATION; CYCLE; MVC;
D O I
10.1016/j.ijrefrig.2017.04.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Due to the reason of water injection, twin screw water vapor compressor can realize higher pressure ratio and saturated temperature lift of compressed vapor. Its application in mechanical vapor compression (MVC) heat pump systems has drawn much attention recently because of the great energy-saving potential and reliability. In this paper, a thermodynamic model of the working process in water injected twin screw water vapor compressor is established, in which heat and mass transfer between water liquid and vapor are considered. Its accuracy is validated by the experimental recorded p-V indicator diagrams. With the proposed model, the compressor performance is simulated and studied. According to the simulation results, water injection can increase the volumetric efficiency 5% and adiabatic indication efficiency 6%. Once the discharged vapor has been cooled to saturation, the shaft power of the compressor will increase while the adiabatic indication efficiency and the volume flow rate together with the volumetric efficiency change little with the continuous increase of injected water. Since the sensible heat of water is much smaller than latent heat, the temperature of injectedwater has little effect on the performance. Both the volume flowrate and shaft power increase linearly with the rotor speed. In addition, the volume flowrate of injectedwater should be adjusted with the regulation of rotor speed to guarantee a saturate discharge temperature. The volumetric efficiency will increase and the adiabatic indication efficiency will decrease slowly with the rise of rotor speed. Due to the cooling and evaporation effects of liquid water at the discharge chamber, the adiabatic indication efficiency does not decline when it operates at under compression condition. Water injection can greatly improve the compressor performance when the compressor operates at under compression or over compression condition, especially where a high saturated temperature lift of compressed vapor is in demand. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:75 / 87
页数:13
相关论文
共 50 条
  • [21] Research on Characteristics of Twin-screw Refrigeration Compressor
    Huang H.
    Wu H.
    Ying W.
    Zhang B.
    Lin K.
    Xiong B.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2019, 55 (24): : 197 - 202
  • [22] 'Twin-screw compressor performance and suitable lubricants with HFC-134a'
    Sjoholm, L.J.
    Short, G.D.
    Proceedings of the 1990 International Compressor Engineering Conference, 1990,
  • [23] Experimental study and model optimization of thermodynamic performance of a single screw water vapor compressor
    Zhang, Huafu
    Zhang, Zhentao
    Tong, Lige
    Yang, Junling
    Li, Yanan
    Wang, Li
    Guo, Xia
    Tian, Rui
    He, Mingxin
    Gao, Chongguang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 161 : 135 - 144
  • [24] Economics of water injected air screw compressor systems
    Madhav, K. Venu
    Kovacevic, A.
    9TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS, 2015, 90
  • [25] CFD simulation for the internal pressure characteristics of an oil-injected twin-screw refrigeration compressor
    Yang, Shengmei
    Ouyang, Hua
    Wu, Yadong
    Wang, Lee
    Mei, Lu
    Wang, Hongdan
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 126 : 143 - 154
  • [26] Water-injected compressors - the state of the art
    Nichol, P
    COMPRESSORS AND THEIR SYSTEMS, 2003, 2003 (04): : 181 - 193
  • [27] Inverter-motor driven, water-injected, oil-free screw air compressor; EmerauDe-Aqua® series
    Totsuka, Junichiro
    R and D: Research and Development Kobe Steel Engineering Reports, 2009, 59 (02): : 45 - 47
  • [28] Experimental study of the axial force on the rotors in a twin-screw refrigeration compressor
    Hou, Feng
    Zhao, Zhaorui
    Yu, Zhiqiang
    Xing, Ziwen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 75 : 155 - 163
  • [29] SUPERCHARGED AND WATER-INJECTED STIRLING ENGINE
    FARBER, EA
    SOLAR ENERGY, 1970, 13 (01) : 134 - &
  • [30] 'Twin-screw compressor performance and complex ester lubricants with HCFC-22'
    Sjoholm, L.I.
    Short, G.D.