Continuous monitoring of cerebrovascular reactivity through pulse transit time and intracranial pressure

被引:2
|
作者
Liu, Xiuyun [1 ]
Gadhoumi, Kais [1 ]
Xiao, Ran [1 ]
Tran, Nate [1 ]
Smielewski, Peter [2 ]
Czosnyka, Marek [2 ]
Hetts, Steven W. [3 ]
Ko, Nerissa [4 ]
Hu, Xiao [1 ,5 ,6 ,7 ]
机构
[1] Univ Calif San Francisco, Dept Physiol Nursing, 2 Koret Way, San Francisco, CA 94143 USA
[2] Univ Cambridge, Dept Clin Neurosci, Brain Phys Lab, Addenbrookes Hosp, Cambridge, England
[3] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Dept Neurol, San Francisco, CA 94143 USA
[5] Univ Calif Los Angeles, Sch Med, Dept Neurosurg, Los Angeles, CA USA
[6] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94143 USA
[7] Univ Calif San Francisco, Inst Computat Hlth Sci, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
cerebrovascular reactivity; intracranial pressure; pulse transit time; non-invasive arterial blood pressure; DYNAMIC CEREBRAL AUTOREGULATION; TRAUMATIC BRAIN-INJURY; SLOW-WAVE OSCILLATIONS; BLOOD-PRESSURE; PERFUSION-PRESSURE; COHERENCE ANALYSIS; HEART-RATE; MODELS; VARIABILITY; OXIMETERS;
D O I
10.1088/1361-6579/aafab1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Cerebrovascular reactivity (CR) is a mechanism that maintains stable blood flow supply to the brain. Pressure reactivity index (PRx), the correlation coefficient between slow waves of invasive arterial blood pressure (ABP) and intracranial pressure (ICP) has been validated for CR assessment. However, in clinical ward, not every subarachnoid hemorrhage (SAH) patient has invasive ABP monitoring. Pulse transit time (PTT), the propagation time of a pulse wave travelling from the heart to peripheral arteries, has been suggested as a surrogate measure of ABP. In this study, we proposed to use PTT instead of invasive ABP to monitor CR. Approach: Forty-five SAH patients with simultaneous recordings of invasive ABP, ICP, oxygen saturation level (SpO2) and electrocardiograph (ECG) were included. PTT was calculated as the time from the ECG R-wave peak to the onset of SpO2. PTT based pressure reactivity index (tPRx) was calculated as the correlation coefficient between slow waves of PTT and ICP. Wavelet tPRx (wtRx) was calculated as the cosine of wavelet phase shift between PTT and ICP. Meanwhile, PRx and wPRx were also calculated using invasive ABP and ICP as input. Main results: The result showed a negative relationship between PIT and ABP (r = -0.58,p < 0.001). tPRx negatively correlated with PRx (r = -0.51, p = 0.003). Wavelet method correlated well with correlation method demonstrated through positive relationship between wPRx and PRx (r = 0.82,p < 0.001) as well as wtPRx and tPRx (r = 0.84, p < 0.001). Significance: PTT demonstrates great potential as a useful tool for CR assessment when invasive ABP is unavailable.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Intracranial pressure variability: relation to clinical outcome, intracranial pressure–volume index, cerebrovascular reactivity and blood pressure variability
    Teodor Svedung Wettervik
    Timothy Howells
    Per Enblad
    Anders Lewén
    Journal of Clinical Monitoring and Computing, 2020, 34 : 733 - 741
  • [42] A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time
    Buxi, Dilpreet
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    PHYSIOLOGICAL MEASUREMENT, 2015, 36 (03) : R1 - R26
  • [43] Design and Development of Pulse Transit Time Based Cuffless Blood Pressure Monitoring System
    Singh, Harinderjit
    Singh, Mandeep
    2015 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, SIGNALS, COMMUNICATION AND OPTIMIZATION (EESCO), 2015,
  • [44] The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time
    Peyman Yousefian
    Sungtae Shin
    Azin Mousavi
    Chang-Sei Kim
    Ramakrishna Mukkamala
    Dae-Geun Jang
    Byung-Hoon Ko
    Jongwook Lee
    Ui Kun Kwon
    Youn Ho Kim
    Jin-Oh Hahn
    Scientific Reports, 9
  • [45] Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice
    Mukkamala, Ramakrishna
    Hahn, Jin-Oh
    Inan, Omer T.
    Mestha, Lalit K.
    Kim, Chang-Sei
    Toreyin, Hakan
    Kyal, Survi
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (08) : 1879 - 1901
  • [46] The Potential of Wearable Limb Ballistocardiogram in Blood Pressure Monitoring via Pulse Transit Time
    Yousefian, Peyman
    Shin, Sungtae
    Mousavi, Azin
    Kim, Chang-Sei
    Mukkamala, Ramakrishna
    Jang, Dae-Geun
    Ko, Byung-Hoon
    Lee, Jongwook
    Kwon, Ui Kun
    Kim, Youn Ho
    Hahn, Jin-Oh
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [47] Continuous monitoring of cerebrovascular pressure reactivity allows determination of optimal cerebral perfusion pressure in patients with traumatic brain injury
    Steiner, LA
    Czosnyka, M
    Piechnik, SK
    Smielewski, P
    Chatfield, D
    Menon, DK
    Pickard, JD
    CRITICAL CARE MEDICINE, 2002, 30 (04) : 733 - 738
  • [48] CONTINUOUS TELEMETRIC MONITORING OF INTRACRANIAL PRESSURE (ICP)
    BROCK, M
    DIEFENTH.K
    HUTTEN, H
    ACTA NEUROCHIRURGICA, 1971, 24 (04) : 339 - &
  • [49] CONTINUOUS INTRACRANIAL-PRESSURE MONITORING IN CHILDREN
    BESSER, M
    JOHNSTON, IH
    MONOGRAPHS IN PAEDIATRICS, 1982, 15 : 131 - 133
  • [50] CONTINUOUS INTRACRANIAL PRESSURE MONITORING IN COMMUNICATING HYDROCEPHALUS
    DORSCH, NWC
    SYMON, L
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1972, 35 (06): : 922 - 923