Experimental investigation of heat transfer augmentation inside double pipe heat exchanger equipped with reduced width twisted tapes inserts using polymeric nanofluid

被引:28
|
作者
Hazbehian, Mohammad [1 ]
Maddah, Heydar [2 ]
Mohammadiun, Hamid [3 ]
Alizadeh, Mostafa [4 ]
机构
[1] Islamic Azad Univ, Shahrood Branch, Dept Chem Engn, Shahrood, Iran
[2] Islamic Azad Univ, Arak Branch, Sci Facul, Dept Chem, Arak, Iran
[3] Islamic Azad Univ, Shahrood Branch, Dept Mech Engn, Shahrood, Iran
[4] Tarbiat Modares Univ, Dept Chem Engn, POB 14155-143, Tehran, Iran
关键词
FRICTION FACTOR CHARACTERISTICS; TRANSFER ENHANCEMENT; LAMINAR-FLOW; CIRCULAR TUBE; PRESSURE-DROP; THERMAL-CONDUCTIVITY; FORCED-CONVECTION; PERFORMANCE; AL2O3/WATER; FEATURES;
D O I
10.1007/s00231-016-1764-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, we report a further enhancement in heat transfer coefficients of base fluid in combination with structural modifications of tape inserts. Polyvinyl Alcohol and TiO2 with mean diameter of 15 nm were chosen as base fluid and nano-particles, respectively. The experiments are carried out in plain tube with four longitudinal internal fins and reduced width twisted tape (RWTT) inserts of twist ratio varying form 2-5 and width of 12-16. Experiments are undertaken to determine heat transfer coefficients and friction factor of TiO2/PVA nanofluid up to 2.0 % volume concentration at an average temperature of 30 A degrees C. The investigations are undertaken in the Reynolds number range of 800-30,000 for flow in tubes and with tapes of different width length ratios. The experiments was verified with well-known correlations. The average Nusselt number and friction factor in the tube fitted with the full-length twisted tapes at y/w = 3.0, and 5.0, are respectively 50-130, and 30-95 % higher than those in the plain tube; 90-220 and 100-270 % when the working fluid is nanofluid, respectively. For the reduced width twisted tapes, the heat transfer rate is decreased with decreasing tapes width. The average Nusselt numbers in the tube fitted with the RWTT of 16, 14 and 12 are respectively, 210-390, 190-320 and 170-290 % of that in the plain tube. With the similar trend mentioned above, RWTT with higher width length yield higher thermal enhancement factor in comparison with smaller width. The use of RWTT led to the highest thermal performance factor up to 1.75. Maximum thermal performance factor which was obtained belonged to twists with twist ratio of 2 and width of 16 with phi = 0.5 % and Reynolds number range of 800-30,000.
引用
收藏
页码:2515 / 2529
页数:15
相关论文
共 50 条
  • [41] Heat transfer augmentation using twisted tape inserts: A review
    Varun
    Garg, M. O.
    Nautiyal, Himanshu
    Khurana, Sourabh
    Shukla, M. K.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 63 : 193 - 225
  • [42] Experimental studies on heat transfer performance of a heat exchanger with drilled twisted tape inserts
    Kumbhar, Dnyaneshwar G.
    Sutar, Kailasnath B.
    Kumar, Archit
    Lavate, Roheshkumar S.
    Pawar, Sanjay R.
    ENGINEERING RESEARCH EXPRESS, 2024, 6 (04):
  • [43] Heat transfer enhancement of nanofluids in a double pipe heat exchanger with louvered strip inserts
    Mohammed, H. A.
    Hasan, Husam A.
    Wahid, M. A.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 40 : 36 - 46
  • [44] Experimental study on heat transfer augmentation in a double pipe heat exchanger utilizing jet vortex flow
    Jawarneh, Ali M.
    Al-Widyan, Mohamad
    Al-Mashhadani, Zain
    HEAT TRANSFER, 2023, 52 (01) : 317 - 332
  • [45] Experimental study of heat transfer enhancement using nanofluid in double tube heat exchanger
    Han, D.
    He, W. F.
    Asif, F. Z.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 2547 - 2553
  • [46] Enhancing heat transfer in a double-tube heat exchanger using perforated twisted tape and nanofluid
    Marzouk, S. A.
    Aljabr, Ahmad
    Almehmadi, Fahad Awjah
    Sharaf, Maisa A.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2025,
  • [47] Heat transfer and fluid flow characteristics of heat exchanger tube with multiple twisted tapes and solid rings inserts
    Singh, Vijaypal
    Chamoli, Sunil
    Kumar, Manoj
    Kumar, Alok
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 102 : 156 - 168
  • [48] Experimental evaluation of heat transfer efficiency of nanofluid in a double pipe heat exchanger and prediction of experimental results using artificial neural networks
    Maddah, Heydar
    Ghasemi, Nahid
    HEAT AND MASS TRANSFER, 2017, 53 (12) : 3459 - 3472
  • [49] Experimental evaluation of heat transfer efficiency of nanofluid in a double pipe heat exchanger and prediction of experimental results using artificial neural networks
    Heydar Maddah
    Nahid Ghasemi
    Heat and Mass Transfer, 2017, 53 : 3459 - 3472
  • [50] Experimental investigation of perforated twisted tapes turbulator on thermal performance in double pipe heat exchangers
    Vaisi, Ahmad
    Moosavi, Rouhollah
    Lashkari, Moslem
    Soltani, M. Mohsen
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 154