Experimental investigation of heat transfer augmentation inside double pipe heat exchanger equipped with reduced width twisted tapes inserts using polymeric nanofluid

被引:28
|
作者
Hazbehian, Mohammad [1 ]
Maddah, Heydar [2 ]
Mohammadiun, Hamid [3 ]
Alizadeh, Mostafa [4 ]
机构
[1] Islamic Azad Univ, Shahrood Branch, Dept Chem Engn, Shahrood, Iran
[2] Islamic Azad Univ, Arak Branch, Sci Facul, Dept Chem, Arak, Iran
[3] Islamic Azad Univ, Shahrood Branch, Dept Mech Engn, Shahrood, Iran
[4] Tarbiat Modares Univ, Dept Chem Engn, POB 14155-143, Tehran, Iran
关键词
FRICTION FACTOR CHARACTERISTICS; TRANSFER ENHANCEMENT; LAMINAR-FLOW; CIRCULAR TUBE; PRESSURE-DROP; THERMAL-CONDUCTIVITY; FORCED-CONVECTION; PERFORMANCE; AL2O3/WATER; FEATURES;
D O I
10.1007/s00231-016-1764-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, we report a further enhancement in heat transfer coefficients of base fluid in combination with structural modifications of tape inserts. Polyvinyl Alcohol and TiO2 with mean diameter of 15 nm were chosen as base fluid and nano-particles, respectively. The experiments are carried out in plain tube with four longitudinal internal fins and reduced width twisted tape (RWTT) inserts of twist ratio varying form 2-5 and width of 12-16. Experiments are undertaken to determine heat transfer coefficients and friction factor of TiO2/PVA nanofluid up to 2.0 % volume concentration at an average temperature of 30 A degrees C. The investigations are undertaken in the Reynolds number range of 800-30,000 for flow in tubes and with tapes of different width length ratios. The experiments was verified with well-known correlations. The average Nusselt number and friction factor in the tube fitted with the full-length twisted tapes at y/w = 3.0, and 5.0, are respectively 50-130, and 30-95 % higher than those in the plain tube; 90-220 and 100-270 % when the working fluid is nanofluid, respectively. For the reduced width twisted tapes, the heat transfer rate is decreased with decreasing tapes width. The average Nusselt numbers in the tube fitted with the RWTT of 16, 14 and 12 are respectively, 210-390, 190-320 and 170-290 % of that in the plain tube. With the similar trend mentioned above, RWTT with higher width length yield higher thermal enhancement factor in comparison with smaller width. The use of RWTT led to the highest thermal performance factor up to 1.75. Maximum thermal performance factor which was obtained belonged to twists with twist ratio of 2 and width of 16 with phi = 0.5 % and Reynolds number range of 800-30,000.
引用
收藏
页码:2515 / 2529
页数:15
相关论文
共 50 条
  • [31] An experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
    Aghayari, R.
    Maddah, H.
    Arani, J. Baghbani
    Mohammadiun, H.
    Nikpanje, E.
    INTERNATIONAL JOURNAL OF NANO DIMENSION, 2015, 6 (05) : 517 - 524
  • [32] Enhancing Heat Transfer Inside a Double Pipe Heat Exchanger Using Al2O3 Nanofluid, Experimental Investigation Under Turbulent Flow Conditions
    Mohamed, Hozaifa A.
    Alhazmy, Majed
    Mansour, F.
    Negeed, El-Sayed R.
    JOURNAL OF NANOFLUIDS, 2023, 12 (02) : 356 - 371
  • [33] Numerical investigation on enhancement of heat transfer using rod inserts in single pipe heat exchanger
    Raheemah, S. H.
    Ashham, M.
    Salman, K.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2019, 13 (04) : 6112 - 6124
  • [34] Heat transfer enhancement of TiO2/water nanofluid in a heat exchanger tube equipped with overlapped dual twisted-tapes
    Eiamsa-ard, S.
    Kiatkittipong, K.
    Jedsadaratanachai, W.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2015, 18 (03): : 336 - 350
  • [35] EXPERIMENTAL INVESTIGATION OF NANOFLUID HEAT TRANSFER IN A PLATE HEAT EXCHANGER
    Taws, Matthew
    Cong Tam Nguyen
    Galanis, Nicolas
    Gherasim, Iulian
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2012, VOL 2, 2012, : 1 - 8
  • [36] Experimental Study of Heat Transfer Enhancement in a Concentric Double Pipe Heat Exchanger with Different Axial Pitch Ratio of Perforated Twisted Tape Inserts
    Yaningsih, Indri
    Istanto, Tri
    Wijayanta, Agung Tri
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE AND EXHIBITION OF SUSTAINABLE ENERGY AND ADVANCED MATERIALS 2015 (ICE-SEAM 2015), 2016, 1717
  • [37] Numerical and experimental investigation of heat transfer enhancement in double tube heat exchanger using nail rod inserts
    Marzouk, S. A.
    Almehmadi, Fahad Awjah
    Aljabr, Ahmad
    Sharaf, Maisa A.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [38] Experimental investigation on heat transfer augmentation of transverse twisted tapes in a confined rectangular channel
    Jaganathan, K. D.
    Sivasubramanian, M.
    MEASUREMENT & CONTROL, 2020, 53 (3-4): : 390 - 399
  • [39] Experimental investigation on heat transfer in double pipe heat exchanger employing triangular fins
    Mathanraj, V
    Krishna, Velaga Leela
    Babu, Jampana Lakshmi Venkanna
    Kumar, S. Arul
    2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING (ICAME 2018), 2018, 402
  • [40] Numerical investigation of turbulent CuO-water nanofluid inside heat exchanger enhanced with double V-cut twisted tapes
    Nakhchi, M. E.
    Esfahani, J. A.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (05) : 2535 - 2545