Experimental investigation of heat transfer augmentation inside double pipe heat exchanger equipped with reduced width twisted tapes inserts using polymeric nanofluid

被引:28
|
作者
Hazbehian, Mohammad [1 ]
Maddah, Heydar [2 ]
Mohammadiun, Hamid [3 ]
Alizadeh, Mostafa [4 ]
机构
[1] Islamic Azad Univ, Shahrood Branch, Dept Chem Engn, Shahrood, Iran
[2] Islamic Azad Univ, Arak Branch, Sci Facul, Dept Chem, Arak, Iran
[3] Islamic Azad Univ, Shahrood Branch, Dept Mech Engn, Shahrood, Iran
[4] Tarbiat Modares Univ, Dept Chem Engn, POB 14155-143, Tehran, Iran
关键词
FRICTION FACTOR CHARACTERISTICS; TRANSFER ENHANCEMENT; LAMINAR-FLOW; CIRCULAR TUBE; PRESSURE-DROP; THERMAL-CONDUCTIVITY; FORCED-CONVECTION; PERFORMANCE; AL2O3/WATER; FEATURES;
D O I
10.1007/s00231-016-1764-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, we report a further enhancement in heat transfer coefficients of base fluid in combination with structural modifications of tape inserts. Polyvinyl Alcohol and TiO2 with mean diameter of 15 nm were chosen as base fluid and nano-particles, respectively. The experiments are carried out in plain tube with four longitudinal internal fins and reduced width twisted tape (RWTT) inserts of twist ratio varying form 2-5 and width of 12-16. Experiments are undertaken to determine heat transfer coefficients and friction factor of TiO2/PVA nanofluid up to 2.0 % volume concentration at an average temperature of 30 A degrees C. The investigations are undertaken in the Reynolds number range of 800-30,000 for flow in tubes and with tapes of different width length ratios. The experiments was verified with well-known correlations. The average Nusselt number and friction factor in the tube fitted with the full-length twisted tapes at y/w = 3.0, and 5.0, are respectively 50-130, and 30-95 % higher than those in the plain tube; 90-220 and 100-270 % when the working fluid is nanofluid, respectively. For the reduced width twisted tapes, the heat transfer rate is decreased with decreasing tapes width. The average Nusselt numbers in the tube fitted with the RWTT of 16, 14 and 12 are respectively, 210-390, 190-320 and 170-290 % of that in the plain tube. With the similar trend mentioned above, RWTT with higher width length yield higher thermal enhancement factor in comparison with smaller width. The use of RWTT led to the highest thermal performance factor up to 1.75. Maximum thermal performance factor which was obtained belonged to twists with twist ratio of 2 and width of 16 with phi = 0.5 % and Reynolds number range of 800-30,000.
引用
收藏
页码:2515 / 2529
页数:15
相关论文
共 50 条
  • [1] Experimental investigation of heat transfer augmentation inside double pipe heat exchanger equipped with reduced width twisted tapes inserts using polymeric nanofluid
    Mohammad Hazbehian
    Heydar Maddah
    Hamid Mohammadiun
    Mostafa Alizadeh
    Heat and Mass Transfer, 2016, 52 : 2515 - 2529
  • [2] Heat transfer augmentation in a double-pipe heat exchanger with dimpled twisted tape inserts: an experimental study
    Soltani, Mohammad Mohsen
    Gorji-Bandpy, Mofid
    Vaisi, Ahmad
    Moosavi, Rouhollah
    HEAT AND MASS TRANSFER, 2022, 58 (09) : 1591 - 1606
  • [3] Heat transfer augmentation in a double-pipe heat exchanger with dimpled twisted tape inserts: an experimental study
    Mohammad Mohsen Soltani
    Mofid Gorji-Bandpy
    Ahmad Vaisi
    Rouhollah Moosavi
    Heat and Mass Transfer, 2022, 58 : 1591 - 1606
  • [4] Theoretical and experimental studies of heat transfer in a double-pipe heat exchanger equipped with twisted tape and nanofluid
    Aghayari, Reza
    Maddah, Heydar
    Pourkiaei, Seyed Mohsen
    Ahmadi, Mohammad Hossein
    Chen, Lingen
    Ghazvini, Mahyar
    EUROPEAN PHYSICAL JOURNAL PLUS, 2020, 135 (02):
  • [5] Theoretical and experimental studies of heat transfer in a double-pipe heat exchanger equipped with twisted tape and nanofluid
    Reza Aghayari
    Heydar Maddah
    Seyed Mohsen Pourkiaei
    Mohammad Hossein Ahmadi
    Lingen Chen
    Mahyar Ghazvini
    The European Physical Journal Plus, 135
  • [6] Experimental investigation of heat transfer enhancement of a heat exchanger tube equipped with double-cut twisted tapes
    Nakhchi, M. E.
    Hatami, M.
    Rahmati, M.
    APPLIED THERMAL ENGINEERING, 2020, 180
  • [7] Numerical Investigation of Heat Transfer Enhancement in Double Pipe Heat Exchanger Using Twisted Tape Inserts
    Hwary, Ahmed S. Z. M.
    Khalil, Essam E.
    AboHadima, Samir
    El-Shabrawy, Mohamed
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 313 - 320
  • [8] Flow and Heat transfer Experimental Investigation of Nanofluid in a Double pipe Heat Exchanger
    Ghalib, Lubna
    Rahma, N. M.
    Eweedand, K. M.
    Al-Kamal, A. K.
    INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING AND SCIENCE, 2018, 454
  • [9] Experimental investigation of heat transfer enhancement in a double pipe heat exchanger with a twisted inner pipe
    Ali, Mahmud H.
    Jalal, Rawand E.
    HEAT TRANSFER, 2021, 50 (08) : 8121 - 8133
  • [10] TiO2/water Nanofluid Heat Transfer in Heat Exchanger Equipped with Double Twisted-Tape Inserts
    Eiamsa-ard, S.
    Ketrain, R.
    Chuwattanakul, V.
    INTERNATIONAL CONFERENCE ON NANOMATERIALS AND BIOMATERIALS (ICNB 2017), 2018, 350