Non-contact Vibro-acoustic Detection Technique for Dental Osseointegration Examination

被引:9
|
作者
Zhuang, Han-Bo [1 ]
Tu, Wei-Shan [1 ]
Pan, Min-Chun [1 ,2 ]
Wu, Jer-Whey [3 ]
Chen, Chin-Sung [4 ]
Lee, Shyh-Yuan [5 ]
Yang, Yuan-Chao [3 ]
机构
[1] Natl Cent Univ, Dept Mech Engn, Jhongli 320, Taiwan
[2] Natl Cent Univ, Grad Inst Biomed Engn, Jhongli 320, Taiwan
[3] Cathay Gen Hosp, Dept Dent, Taipei 106, Taiwan
[4] Sijhih Cathay Gen Hosp, Dept Dent, Sijhih 221, Taiwan
[5] Natl Yang Ming Univ, Sch Dent, Fac Dent, Taipei 112, Taiwan
关键词
Dental implant; Osseointegration; Bone defect detection; Non-contact vibro-acoustic measurement; RESONANCE FREQUENCY-ANALYSIS; IMPLANT STABILITY; NUMERICAL APPROACH; TITANIUM IMPLANTS; TOOTH MOBILITY; IN-VIVO; BONE; VALIDATION; SIMULATION; INTERFACE;
D O I
10.5405/jmbe.993
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study develops a non-contact vibro-acoustic detection technique for measuring the defect quantity and determining the imperfection orientation surrounding a bone-implant interface. Acoustic excitation through a miniature loud speaker and vibration response measurement using a capacity-type displacement sensor are applied to accomplish this task to prevent the mass loading effect on the structure to be examined. The proposed non-contact excitation-response measurements are verified using a series of designated in vitro defect models, and the measured resonance frequencies (RFs) are used to discriminate interfacial structure variations. A finite element modal analysis is conducted to validate the measured RFs. Additionally, a prototype device is developed and applied to assess the osseointegration between dental implants and tibia in an in vivo animal model. A comparison of in vitro experimental results with numerical simulations shows that the RFs in the defective orientation are significantly smaller than those in the complete direction (p < 0.05), and that the values decrease with increasing defect quantity (p < 0.05). Moreover, the defect depth affects RF variation. In the in vivo experiments, the RF levels in the lateral direction of the tibia are much higher than those in the axial direction (p < 0.05) of the tibia. The RF values in the axial direction for two implants have no significant difference (p = 0.552), but the RFs in the lateral direction for implant 2 are higher than those for implant 1 (p < 0.05). The RF changes can be compared to assess osseointegration development. The proposed technique is promising for assisting dentists in the assessment of implant stability after surgery.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [41] An efficient computational technique for 3D vibro-acoustic thanks to the VTCR
    Louis, Kovalevsky
    Pierre, Ladeveze
    Herve, Riou
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2011, 2011, : 3133 - 3138
  • [42] Tribological and vibro-acoustic behaviour of a contact between rubber and glass (Application to Wiper Blade)
    Koenen, A.
    Sanon, A.
    Dahm, K. L.
    Mathia, T.
    TRIBOLOGY INTERNATIONAL, 2007, 40 (10-12) : 1728 - 1728
  • [43] Method for vibro-acoustic signal processing for detection of nascent defect of mechanical assemblies
    Lange, P.
    Yaroslavkina, E.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ACTUAL ISSUES OF MECHANICAL ENGINEERING 2017 (AIME 2017), 2017, 133 : 903 - 908
  • [44] Acoustoelastic measurements on aluminium alloy by means of a contact and a non-contact (LFB acoustic microscopy) technique
    Berruti, T
    Gola, MM
    Briggs, GAD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 103 (03): : 1370 - 1376
  • [45] Local bispectral characteristics of nonlinear vibro-acoustic modulations for structural damage detection
    Czelusniak, Krzysztof
    Staszewski, Wieslaw J.
    Aymerich, Francesco
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 178
  • [46] Development of Leak Detection System for PVC Pipeline Through Vibro-Acoustic Emission
    Ferino, Daniel C.
    Jose, Raniel P.
    Ochoa, John Revilo M.
    Villamiel, Vincci V.
    Arana, Jasper Meynard P.
    PROCEEDINGS OF TENCON 2018 - 2018 IEEE REGION 10 CONFERENCE, 2018, : 2557 - 2560
  • [47] Vibro-acoustic methods of insect detection in agricultural shipments and wood packing materials
    Sutin, Alexander
    Flynn, Timothy
    Salloum, Hady
    Sedunov, Nikolay
    Sinelnikov, Yegor
    Hull-Sanders, Helen
    2017 IEEE INTERNATIONAL SYMPOSIUM ON TECHNOLOGIES FOR HOMELAND SECURITY (HST), 2017,
  • [48] Incipient cavitation detection in external gear pumps by means of vibro-acoustic measurements
    Battarra, Mattia
    Mucchi, Emiliano
    MEASUREMENT, 2018, 129 : 51 - 61
  • [49] Compact Probe for Non-Contact Ultrasonic Inspection with the Gas-Coupled Laser Acoustic Detection (GCLAD) Technique
    Vangi, D.
    Bruzzi, M.
    Caron, J. N.
    Gulino, M. S.
    EXPERIMENTAL MECHANICS, 2022, 62 (03) : 403 - 415
  • [50] Compact Probe for Non-Contact Ultrasonic Inspection with the Gas-Coupled Laser Acoustic Detection (GCLAD) Technique
    D. Vangi
    M. Bruzzi
    J. N. Caron
    M. S. Gulino
    Experimental Mechanics, 2022, 62 : 403 - 415