Non-contact Vibro-acoustic Detection Technique for Dental Osseointegration Examination

被引:9
|
作者
Zhuang, Han-Bo [1 ]
Tu, Wei-Shan [1 ]
Pan, Min-Chun [1 ,2 ]
Wu, Jer-Whey [3 ]
Chen, Chin-Sung [4 ]
Lee, Shyh-Yuan [5 ]
Yang, Yuan-Chao [3 ]
机构
[1] Natl Cent Univ, Dept Mech Engn, Jhongli 320, Taiwan
[2] Natl Cent Univ, Grad Inst Biomed Engn, Jhongli 320, Taiwan
[3] Cathay Gen Hosp, Dept Dent, Taipei 106, Taiwan
[4] Sijhih Cathay Gen Hosp, Dept Dent, Sijhih 221, Taiwan
[5] Natl Yang Ming Univ, Sch Dent, Fac Dent, Taipei 112, Taiwan
关键词
Dental implant; Osseointegration; Bone defect detection; Non-contact vibro-acoustic measurement; RESONANCE FREQUENCY-ANALYSIS; IMPLANT STABILITY; NUMERICAL APPROACH; TITANIUM IMPLANTS; TOOTH MOBILITY; IN-VIVO; BONE; VALIDATION; SIMULATION; INTERFACE;
D O I
10.5405/jmbe.993
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study develops a non-contact vibro-acoustic detection technique for measuring the defect quantity and determining the imperfection orientation surrounding a bone-implant interface. Acoustic excitation through a miniature loud speaker and vibration response measurement using a capacity-type displacement sensor are applied to accomplish this task to prevent the mass loading effect on the structure to be examined. The proposed non-contact excitation-response measurements are verified using a series of designated in vitro defect models, and the measured resonance frequencies (RFs) are used to discriminate interfacial structure variations. A finite element modal analysis is conducted to validate the measured RFs. Additionally, a prototype device is developed and applied to assess the osseointegration between dental implants and tibia in an in vivo animal model. A comparison of in vitro experimental results with numerical simulations shows that the RFs in the defective orientation are significantly smaller than those in the complete direction (p < 0.05), and that the values decrease with increasing defect quantity (p < 0.05). Moreover, the defect depth affects RF variation. In the in vivo experiments, the RF levels in the lateral direction of the tibia are much higher than those in the axial direction (p < 0.05) of the tibia. The RF values in the axial direction for two implants have no significant difference (p = 0.552), but the RFs in the lateral direction for implant 2 are higher than those for implant 1 (p < 0.05). The RF changes can be compared to assess osseointegration development. The proposed technique is promising for assisting dentists in the assessment of implant stability after surgery.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 50 条
  • [21] CRACK DETECTION ON WIND TURBINE BLADES IN AN OPERATING ENVIRONMENT USING VIBRO-ACOUSTIC MODULATION TECHNIQUE
    Kim, S.
    Adams, D. E.
    Sohn, H.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 32A AND 32B, 2013, 1511 : 286 - 293
  • [22] Wideband excitation in nonlinear vibro-acoustic modulation for damage detection
    Klepka, A.
    Adamczyk, M.
    Pieczonka, L.
    Staszewski, W. J.
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2016, 2016, 9805
  • [23] Demodulation technique to identify nonlinear characteristics of vibro-acoustic NDT measurements
    Carcione, A.
    Blanloeuil, P.
    Veidt, M.
    JOURNAL OF SOUND AND VIBRATION, 2020, 466
  • [24] Efficient swept sine chirp excitation in the non-linear vibro-acoustic wave modulation technique used for damage detection
    Dziedziech, Kajetan
    Pieczonka, Lukasz
    Adamczyk, Maciej
    Klepka, Andrzej
    Staszewski, Wieslaw J.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2018, 17 (03): : 565 - 576
  • [25] Non-contact acoustic microscopy
    Clark, M
    Sharples, S
    Somekh, M
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (12) : 1792 - 1801
  • [26] Steel Material Degradation Assessment Via Vibro-Acoustic Modulation Technique
    Ramezani, Majid G.
    Golchinfar, Behnoush
    Donskoy, Dimitri
    Hassiotis, Sophia
    Venkiteela, Giri
    TRANSPORTATION RESEARCH RECORD, 2019, 2673 (10) : 579 - 585
  • [27] Vibro-Acoustic Modulation technique comparison with conventional nondestructive evaluation methods
    Golchinfar, Behnoush
    Ramezani, Majid G.
    Donskoy, Dimitri
    Saboonchi, Hossain
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS IX, 2020, 11381
  • [28] Impact damage detection in laminated composites by non-linear vibro-acoustic wave modulations
    Klepka, A.
    Pieczonka, L.
    Staszewski, W. J.
    Aymerich, F.
    COMPOSITES PART B-ENGINEERING, 2014, 65 : 99 - 108
  • [29] Non-Contact Detection of Radiation-Induced Acoustic Emissions
    Kim, K.
    Kim, T.
    Katta, N.
    Duong, K.
    Bobba, S.
    Milner, T.
    Xiang, L.
    MEDICAL PHYSICS, 2022, 49 (06) : E981 - E981
  • [30] Fourier spectral element for simulation of vibro-acoustic modulation caused contact in the beam
    Sepehry, Naserodin
    Ehsani, Mohammad
    Asadi, Sina
    Shamshirsaz, Mahnaz
    Nejad, Firooz Bakhtiari
    THIN-WALLED STRUCTURES, 2022, 174