Chirp-Encoded Excitation for Dual-Frequency Ultrasound Tissue Harmonic Imaging

被引:31
|
作者
Shen, Che-Chou [1 ]
Lin, Chin-Hsiang [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
CODED EXCITATION; MEDICAL ULTRASOUND; DISTORTION; SIGNALS; SYSTEM;
D O I
10.1109/TUFFC.2012.2474
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Dual-frequency (DF) transmit waveforms comprise signals at two different frequencies. With a DF transmit waveform operating at both fundamental frequency (f(0)) and second-harmonic frequency (2f(0)), tissue harmonic imaging can be simultaneously performed using not only the conventional 2f(0) second-harmonic signal but also using the f(0) frequency-difference harmonic signal. Nonetheless, when chirp excitation is incorporated into the DF transmit waveform for harmonic SNR improvement, a particular waveform design is required to maintain the bandwidth of the f(0) harmonic signal. In this study, two different DF chirp waveforms are proposed to produce equal harmonic bandwidth at both the f(0) and 2f(0) frequencies to achieve speckle reduction by harmonic spectral compounding and to increase harmonic SNR for enhanced penetration and sensitivity. The UU13 waveform comprises an up-sweeping f(0) chirp and an up-sweeping 2f(0) chirp with triple bandwidth, whereas the UD11 waveform includes an up-sweeping f(0) chirp and a down-sweeping 2f(0) chirp with equal bandwidth. Experimental results indicate that the UU13 tends to suffer from a high range side lobe level resulting from 3f(0) interference. Consequently, the 2f(0) harmonic envelopes of the UD11 and the UU13 waveforms have compression qualities of 87% and 77%, respectively, when the signal bandwidth is 30%. When the bandwidth increases to 50%, the compression quality of the 2f(0) harmonic envelope degrades to 78% and 54%, respectively, for the UD11 and the UU13 waveforms. The compression quality value of the f(0) harmonic envelope remains similar between the two DF transmit waveforms for all signal bandwidths. B-mode harmonic images also show that the UD11 is less contaminated by range side lobe artifacts than is the UU13. Compared with a short pulse with equal bandwidth, the UD11 waveform not only preserves the same spatial resolution after compression but also improves the image SNR by about 10 dB. Moreover, the image contrast-to-noise ratio (CNR), defined as the ratio of the mean to the standard deviation of image intensity in the speckle region, can be increased from 1.0 to about 1.2 when DF spectral compounding is performed. Therefore, it is concluded that the UD11 waveform is a potential solution for chirp-encoded DF harmonic imaging.
引用
收藏
页码:2420 / 2430
页数:11
相关论文
共 50 条
  • [1] Tissue Harmonic Compounded Imaging with Dual-Frequency Chirp Excitation
    Lin, Chin-Hsiang
    Shen, Che-Chou
    [J]. 2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 370 - 373
  • [2] Range Side Lobe Inversion for Chirp-Encoded Dual-Band Tissue Harmonic Imaging
    Shen, Che-Chou
    Peng, Jun-Kai
    Wu, Chi
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (02) : 376 - 384
  • [3] Range Side-lobe Inversion for Dual-Frequency Harmonic Imaging with Chirp Excitation
    Shen, Che-Chou
    Peng, Chun-Kai
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 33 - 36
  • [4] Design of Chirp Excitation Waveform for Dual-Frequency Harmonic Contrast Detection
    Shen, Che-Chou
    Chiu, Yi-Yuan
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) : 2198 - 2206
  • [5] Dual-Frequency Chirp Excitation for Passive Cavitation Imaging in the Brain
    Lin, Hsiang-Ching
    Fan, Ching-Hsiang
    Ho, Yi-Ju
    Yeh, Chih-Kuang
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (06) : 1127 - 1140
  • [6] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, ME
    Goertz, DE
    Vos, HJ
    Droog, E
    Blacquière, G
    Gisolf, A
    van der Steen, AFW
    [J]. 2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 241 - 244
  • [7] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, Martijn E.
    Goertz, David E.
    Vos, Hendrik J.
    Tesselaar, Erik
    Blacquiere, Gerrit
    Gisolf, Andries
    Krams, Rob
    van der Steen, Antonius F. W.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (11): : 1649 - 1654
  • [8] Dual-frequency chirp imaging for contrast detection
    Cheng, Chih-Hao
    Shen, Che-Chou
    Yeh, Chih-Kuang
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09): : 2767 - 2778
  • [9] Golay-Encoded Excitation for Dual-Frequency Harmonic Detection of Ultrasonic Contrast Agents
    Shen, Che-Chou
    Shi, Tai-Yu
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (02) : 349 - 356
  • [10] Dual-frequency Super Harmonic Imaging Piezoelectric Transducers for Transrectal Ultrasound
    Kim, Jinwook
    Li, Sibo
    Kasoji, Sandeep
    Dayton, Paul A.
    Jiang, Xiaoning
    [J]. HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2015, 2015, 9438