Range Side-lobe Inversion for Dual-Frequency Harmonic Imaging with Chirp Excitation

被引:1
|
作者
Shen, Che-Chou [1 ]
Peng, Chun-Kai [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Tissue harmonic imaging; Dual-frequency; Chirp excitation; Range side lobe; ULTRASOUND;
D O I
10.1109/ULTSYM.2013.0009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Compared to conventional single-frequency harmonic imaging, dual-frequency harmonic imaging has been proposed by transmitting and receiving at both fundamental frequency (f(0)) and second harmonic frequency (2f(0)) to achieve spectral compounding for improved image quality. In our previous work, particular chirp excitation is developed to boost the harmonic generation for dual-frequency harmonic imaging while maintaining the harmonic signal bandwidths. However, spectral overlap between the harmonic imaging bands may lead to marked range side lobes and corresponding image artifacts. In this study, a range side lobe inversion (RSI) method has been developed to change the polarity of the range side lobes by firing an auxiliary chirp. When the original and auxiliary chirps are combined, the range side lobes can be eliminated. The RSI method has been verified using hydrophone measurement and B-mode imaging. When the signal bandwidth is 60 %, the compression quality improves by 16 % which corresponds to a 7-dB decrease of side-lobe-magnitude (SLM) in harmonic imaging. Therefore, the RSI method can effectively eliminate the range side lobes and suppress the image artifacts in DF harmonic imaging.
引用
收藏
页码:33 / 36
页数:4
相关论文
共 50 条
  • [1] Orthogonal Golay excitation for range side lobe elimination in dual-frequency harmonic imaging
    Shen, Che-Chou
    Peng, Jun-Kai
    Wu, Chi
    Liu, Chia-Yuan
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 18 : 386 - 393
  • [2] Tissue Harmonic Compounded Imaging with Dual-Frequency Chirp Excitation
    Lin, Chin-Hsiang
    Shen, Che-Chou
    [J]. 2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 370 - 373
  • [3] Range Side Lobe Inversion for Chirp-Encoded Dual-Band Tissue Harmonic Imaging
    Shen, Che-Chou
    Peng, Jun-Kai
    Wu, Chi
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (02) : 376 - 384
  • [4] Supplementary Golay pair for range side lobe suppression in dual-frequency tissue harmonic imaging
    Shen, Che-Chou
    Wu, Chi
    Peng, Jun-Kai
    [J]. ULTRASONICS, 2015, 56 : 477 - 486
  • [5] Chirp-Encoded Excitation for Dual-Frequency Ultrasound Tissue Harmonic Imaging
    Shen, Che-Chou
    Lin, Chin-Hsiang
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (11) : 2420 - 2430
  • [6] Design of Chirp Excitation Waveform for Dual-Frequency Harmonic Contrast Detection
    Shen, Che-Chou
    Chiu, Yi-Yuan
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) : 2198 - 2206
  • [7] Dual-Frequency Chirp Excitation for Passive Cavitation Imaging in the Brain
    Lin, Hsiang-Ching
    Fan, Ching-Hsiang
    Ho, Yi-Ju
    Yeh, Chih-Kuang
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (06) : 1127 - 1140
  • [8] Dual-frequency chirp imaging for contrast detection
    Cheng, Chih-Hao
    Shen, Che-Chou
    Yeh, Chih-Kuang
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09): : 2767 - 2778
  • [9] Orthogonal Encoding for High-bit Golay Excitation in Dual-Frequency Harmonic Imaging
    Shen, Che-Chou
    Peng, Chun-Kai
    [J]. Proceedings of the 2015 ICU International Congress on Ultrasonics, 2015, 70 : 1109 - 1113
  • [10] Harmonic intravascular ultrasound imaging with a dual-frequency catheter
    Frijlink, ME
    Goertz, DE
    Vos, HJ
    Droog, E
    Blacquière, G
    Gisolf, A
    van der Steen, AFW
    [J]. 2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 241 - 244