Development and validation of a rapid and sensitive liquid chromatography-tandem mass spectrometry method for benvitimod quantification in human plasma

被引:6
|
作者
Zhao, Libo [1 ]
Zhu, Baoying [2 ]
Chen, Xin [1 ]
Chen, Genghui [3 ]
Chen, Haibo [4 ]
Li, Yuzhen [1 ]
Jing, Shan [1 ]
Fang, Yi [1 ]
机构
[1] Peking Univ Peoples Hosp, Dept Pharm, Beijing 100044, Peoples R China
[2] Guiyang Med Coll, Guiyang 550004, Peoples R China
[3] Celestial Pharmaceut Co Ltd, Shenzhen 518057, Peoples R China
[4] Xuzhou Med Coll, Xuzhou 221004, Peoples R China
关键词
Benvitimod; LC/ESI/MS/MS; Human plasma; Pharmacokinetics; PERFORMANCE;
D O I
10.1016/j.jchromb.2011.12.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Benvitimod is a newly synthesized non-steroid small molecule being developed as a candidate drug for the treatment of inflammatory skin diseases. Here a rapid, sensitive and specific high performance liquid chromatography-tandem mass spectrometry (LC/ESI/MS/MS) method was developed for the determination of benvitimod in human plasma. The samples were alkalified with disodium tetraborate firstly, and then extracted by methyl tert-butyl ether. Fluorophenyl-benvitimod was used as internal standard (IS.). Chromatographic separation was performed on an Ultra C-18 column (150 mm x 2.1 mm, 5.0 mu m). The mixed mobile phase delivered at 300 mu l/min was CH3CN/H2O, 76.65:23.35 (v/v), containing 0.2 mmol/L NH4COOH. Detection and quantitation was performed by electrospray ionization (ESI) and multiple reaction monitoring (MRM) in the negative ion mode. The most intense [M-H](-) MRM transition of benvitimod at m/z 253.1 -> 211.0 was used for benvitimod quantitation and the transition at m/z 270.9 -> 229.2 was used to monitor I.S. The calibration curve was linear within the concentration range of 0.1-10.0 ng/mL (r > 0.99). The lower limit of quantification (LLOQ) was 0.1 ng/mL. The extraction recovery was above 80%. The accuracy expressed as relative error (RE) was less than 1.03%. The intra- and inter-day precisions were less than 11.81%. The freeze-thaw stability was also investigated and it was found that both benvitimod and the 1.5. were quite stable. This method is especially useful for the pharmacokinetic study of benvitimod. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [21] Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of meloxicam in human plasma
    Wiesner, JL
    de Jager, AD
    Sutherland, FCW
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01): : 115 - 121
  • [22] Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of stavudine in human plasma
    Wiesner, JL
    Sutherland, FCW
    Smit, MJ
    van Essen, GH
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 129 - 134
  • [23] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of levodropropizine in human plasma
    Tang, YB
    Zhao, LM
    Wang, YW
    Fawcett, JP
    Gu, JK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 185 - 189
  • [24] Development and validation of a simple and sensitive liquid chromatography-tandem mass spectrometry method for quantifying trimetazidine in human plasma
    Zhou, Gan
    Tan, Zhi-Rong
    Ouyang, Dong-Sheng
    Chen, Yao
    Guo, Dong
    Xie, Hai-Tang
    Liu, Ying-Zi
    Fan, Lan
    Deng, Han-Wu
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2010, 37 (04) : 501 - 505
  • [25] Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of opiorphin in human saliva
    Brkljacic, Lidija
    Sabalic, Maja
    Salaric, Ivan
    Jeric, Ivanka
    Alajbeg, Ivan
    Nemet, Ina
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32): : 3920 - 3926
  • [26] Development and validation of a sensitive method for hydromorphone in human plasma by normal phase liquid chromatography-tandem mass spectrometry
    Weng, ND
    Jiang, XY
    Newland, K
    Coe, R
    Lin, P
    Lee, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 23 (04) : 697 - 704
  • [27] Liquid chromatography-tandem mass spectrometry method for the quantification of deglymidodrine in human plasma
    Jia, JY
    Liu, GY
    Li, SJ
    Li, XC
    Yuan, WF
    Yu, C
    Wang, YP
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (03) : 715 - 719
  • [28] THE DEVELOPMENT OF A LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY METHOD FOR THE QUANTIFICATION OF OXFENDAZOLE IN HUMAN PLASMA.
    Bach, T.
    Bae, S.
    D'Cunha, R.
    Winokur, P. L.
    An, G.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2018, 103 : S22 - S22
  • [29] Development and Validation of Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantification of Diclofenac in Human Plasma
    Grover, Parul
    Bhardwaj, Monika
    Mehta, L.
    Kumar, Sandeep
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 85 (03) : 740 - 752
  • [30] Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Glycopyrrolate in Horse Plasma
    Rumpler, M. J.