Development and Validation of Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantification of Diclofenac in Human Plasma

被引:0
|
作者
Grover, Parul [1 ]
Bhardwaj, Monika [2 ]
Mehta, L. [3 ]
Kumar, Sandeep [4 ]
机构
[1] Delhi NCR, KIET Grp Inst, KIET Sch Pharm, Ghaziabad 201206, Uttar Pradesh, India
[2] Indian Inst Integrat Med, Nat Prod Chem Div, Canal Rd, Jammu 180001, Jammu And Kashm, India
[3] Amity Univ, Amity Inst Pharm, Noida 201301, Uttar Pradesh, India
[4] Natl Inst Pharmaceut Educ & Res, Dept Regulatory Affairs, Hyderabad 500037, Telangana, India
关键词
Diclofenac; validation; liquid chromatography-tandem mass spectrophotometry; human; plasma; multiple reaction monitoring; pharmacokinetics; HPLC METHOD; PERFORMANCE; SODIUM;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
According to Food and Drug Administration requirements, a simple, sensitive and specific liquid chromatography-tandem mass spectrophotometry method for quantifying diclofenac in human plasma was developed and fully validated. Electrospray ionisation in the positive mode produced protonated ions, which were utilised to detect analyte and fluconazole (internal standard). Protein precipitation generated by acetonitrile was used to extract the analytes, followed by liquid-liquid extraction with ethyl acetate. The reversed phase separation was performed on a Chromolith speed ROD RP-18e (4.6 mmx50 mm) column with a simple isocratic mobile phase of 10 mM ammonium acetate in water, pH adjusted to 4.5 using acetic acid:acetonitrile in the ratio of (20:80, v/v) at a flow rate of 0.5 ml min-1. On a triple quadrupole mass spectrometer, fragmentation of Diclofenac m/z 296.10- (parent) and 250 (product) and Fluconazole m/z 307.20- (parent) and 220 (product) for internal standard was monitored. The devised method was verified in human plasma spanning a concentration range of 18.75 to 2000.25 ng ml-1, with a correlation coefficient (r2) of 0.9948. The detection was carried out using an electrospray ionisation approach on a triple quadrupole mass spectrometer that was used for multiple reaction monitoring. The intraday precision and accuracy values obtained from six different sets of quality control samples evaluated on different occasions ranged from 96.22-113.46 % and 2.66-9.95 %, respectively. For the analyte and internal standard, the overall recoveries were 61.98 3.97 and 55.01 1.18, respectively. The described approach was used to analyse diclofenac in human plasma samples with great performance.
引用
收藏
页码:740 / 752
页数:13
相关论文
共 50 条
  • [1] Development and Validation of Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantification of Ciprofibrate From Human Plasma
    Shah, Dimal
    Mavani, Dilip
    Patel, Harilal
    Baldania, Sunil
    Bhatt, Kashyap
    Chhalotiya, Usmangani
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (02) : 219 - 225
  • [2] Development and validation of a liquid chromatography-tandem mass spectrometric method for the determination of α-methyltyrosine in human plasma
    Humphries, D
    Ruterbories, K
    Chan, C
    Narayanan, R
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (02): : 229 - 234
  • [3] Validation of a method for quantification of ketobemidone in human plasma with liquid chromatography-tandem mass spectrometry
    Lampinen, M
    Bondesson, U
    Fredriksson, E
    Hedeland, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02): : 347 - 354
  • [4] Development and validation of a high-performance liquid chromatography-tandem mass spectrometric method for quantification of daunorubicin in rat plasma
    Yang, Yuhui
    TALANTA, 2007, 71 (02) : 596 - 604
  • [5] Development and validation of high-throughput liquid chromatography-tandem mass spectrometric method for simultaneous quantification of loratadine and desloratadine in human plasma
    Srinubabu, G.
    Patel, Rajaram S.
    Shedbalkarar, Vinay P.
    Rao, Allam Appa
    Rao, M. Narasimha
    Bandaru, Vera Venkata Ratnam
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 860 (02): : 202 - 208
  • [6] Development and validation of a liquid chromatography-tandem mass spectrometric method for the quantification of 5-thio-D-glucose in rat and human plasma
    Mizuno-Yasuhira, Akiko
    Jingu, Shigeji
    Okuyama, Shigeru
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 8 - 14
  • [7] Development and validation of a hydrophilic interaction liquid chromatography-tandem mass spectrometric method for the analysis of paroxetine in human plasma
    Weng, ND
    Eerkes, A
    BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (01) : 28 - 36
  • [8] Development and validation of a liquid chromatography-tandem mass spectrometric method for the determination of the major metabolites of duloxetine in human plasma
    Satonin, Darlene K.
    McCulloch, Julie D.
    Kuo, Fengjiun
    Knadler, Mary Pat
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 582 - 589
  • [9] Quantification of Fluoxetine in Human Plasma by the Development of Liquid Chromatography-tandem Mass Spectrometry Method
    Negi, Geeta
    Majeed, Jaseela
    Arora, Saurabh
    Rana, Sachin
    Singh, Manoj
    Tomar, Jaideep
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2021, 55 (01) : S303 - S311
  • [10] Development and validation of an ultra performance liquid chromatography-tandem mass spectrometry method for the quantification of daptomycin in human plasma
    Bazoti, Fotini N.
    Gikas, Evangelos
    Skoutelis, Athanasios
    Tsarbopoulos, Anthony
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (01) : 78 - 85