Development and Validation of Liquid Chromatography-Tandem Mass Spectrometric Method for the Quantification of Diclofenac in Human Plasma

被引:0
|
作者
Grover, Parul [1 ]
Bhardwaj, Monika [2 ]
Mehta, L. [3 ]
Kumar, Sandeep [4 ]
机构
[1] Delhi NCR, KIET Grp Inst, KIET Sch Pharm, Ghaziabad 201206, Uttar Pradesh, India
[2] Indian Inst Integrat Med, Nat Prod Chem Div, Canal Rd, Jammu 180001, Jammu And Kashm, India
[3] Amity Univ, Amity Inst Pharm, Noida 201301, Uttar Pradesh, India
[4] Natl Inst Pharmaceut Educ & Res, Dept Regulatory Affairs, Hyderabad 500037, Telangana, India
关键词
Diclofenac; validation; liquid chromatography-tandem mass spectrophotometry; human; plasma; multiple reaction monitoring; pharmacokinetics; HPLC METHOD; PERFORMANCE; SODIUM;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
According to Food and Drug Administration requirements, a simple, sensitive and specific liquid chromatography-tandem mass spectrophotometry method for quantifying diclofenac in human plasma was developed and fully validated. Electrospray ionisation in the positive mode produced protonated ions, which were utilised to detect analyte and fluconazole (internal standard). Protein precipitation generated by acetonitrile was used to extract the analytes, followed by liquid-liquid extraction with ethyl acetate. The reversed phase separation was performed on a Chromolith speed ROD RP-18e (4.6 mmx50 mm) column with a simple isocratic mobile phase of 10 mM ammonium acetate in water, pH adjusted to 4.5 using acetic acid:acetonitrile in the ratio of (20:80, v/v) at a flow rate of 0.5 ml min-1. On a triple quadrupole mass spectrometer, fragmentation of Diclofenac m/z 296.10- (parent) and 250 (product) and Fluconazole m/z 307.20- (parent) and 220 (product) for internal standard was monitored. The devised method was verified in human plasma spanning a concentration range of 18.75 to 2000.25 ng ml-1, with a correlation coefficient (r2) of 0.9948. The detection was carried out using an electrospray ionisation approach on a triple quadrupole mass spectrometer that was used for multiple reaction monitoring. The intraday precision and accuracy values obtained from six different sets of quality control samples evaluated on different occasions ranged from 96.22-113.46 % and 2.66-9.95 %, respectively. For the analyte and internal standard, the overall recoveries were 61.98 3.97 and 55.01 1.18, respectively. The described approach was used to analyse diclofenac in human plasma samples with great performance.
引用
收藏
页码:740 / 752
页数:13
相关论文
共 50 条
  • [21] Development and validation of a liquid chromatography-tandem mass spectrometric method for the determination of lenalidomide in human plasma and its application on bioequivalence studies
    Gopinath, R.
    Narenderan, S. T.
    Kumar, M.
    Babu, B.
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2019, 10 (01)
  • [22] Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Glycopyrrolate in Horse Plasma
    Rumpler, M. J.
    Sams, R. A.
    Colahan, P.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (09) : 656 - 664
  • [23] Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Estimation of Rivaroxaban in Human Plasma
    Pathan, Mudassarahemadkhan
    Kshirsagar, Ajay
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (06) : 876 - 889
  • [24] Development and validation of a liquid chromatography-tandem mass spectrometry method for determination of ibuprofen in human plasma
    Puangpetch, Apichaya
    Limrungsikul, Anchalee
    Prommas, Santirhat
    Rukthong, Pattarawit
    Sukasem, Chonlaphat
    CLINICAL MASS SPECTROMETRY, 2020, 15 : 6 - 12
  • [25] Development and validation of a liquid chromatography-tandem mass spectrometric assay for pitavastatin and its lactone in human plasma and urine
    Tian, Lei
    Huang, Yiling
    Jia, Youhong
    Hua, Lu
    Li, Yishi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 865 (1-2): : 127 - 132
  • [26] Development and validation of a liquid chromatography-tandem mass spectrometric assay for Eplerenone and its hydrolyzed metabolite in human plasma
    Zhang, JY
    Fast, DM
    Breau, AP
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 787 (02): : 333 - 344
  • [27] Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in human plasma
    Wang, Haidong
    Deng, Pan
    Chen, Xiaoyan
    Guo, Lixia
    Zhong, Dafang
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (01) : 34 - 38
  • [28] Validation of a Liquid Chromatography-Tandem Mass Spectrometric Assay for Quantitative Analysis of Lenvatinib in Human Plasma
    Ogawa-Morita, Tomoko
    Sano, Yoshiyuki
    Okano, Tomoka
    Fujii, Hirofumi
    Tahara, Makoto
    Yamaguchi, Masakazu
    Minami, Hironobu
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 2017
  • [29] Liquid chromatography-tandem mass spectrometric analysis of stobadine in human plasma
    Abdel-Hamid, ME
    Novotny, L
    Stankovicova, M
    Benes, L
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (03) : 383 - 393
  • [30] Solid phase extraction and quantification of diclofenac sodium in human plasma by liquid chromatography-tandem mass spectrometry
    Nalini Kanta Sahoo
    Madhusmita Sahu
    Podilapu Srinivasa Rao
    Goutam Ghosh
    Journal of Analytical Chemistry, 2015, 70 : 424 - 430