Development of a disposable amperometric immunosensor for the detection of ecstasy and its analogues using screen-printed electrodes

被引:27
|
作者
Butler, D [1 ]
Pravda, M [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Sensors Dev Grp, Cork, Ireland
关键词
ecstasy; immunosensor; screen-printed electrodes; saliva; urine;
D O I
10.1016/j.aca.2005.09.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric immunosensor for the specific and simple detection of 3,4-methylenedioxyamphetamine (MDA) and its analogues, 3,4methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyethylamphetamine (MDEA) in saliva and urine was developed. A direct competitive assay in which free analyte and horseradish peroxidase labelled species were simultaneously added to an immobilised polyclonal antibody was employed. Both MDA and MDMA could be labelled with the enzyme and the use of an MDMA-HRP tracer greatly enhanced the sensitivity of the assay. Amperometric detection was per-formed at +100mV versus Ag/AgCl, using tetramethylbenzidine (TMB)/H2O2 as substrate. The antibody, raised specifically against the methylenedioxy moiety of an MDA-BSA immunogen allowed highly specific detection of these analogues with negligible cross-reactivity towards any other amphetamine related compounds. Total assay time was 45 min and the standard curve using MDA could be evaluated within the range 0.61-400 ng ml(-1) with corresponding limit of detection (LOD) of 0.36 and 0.042 ng ml(-1) for saliva and urine, respectively. The cross-reactivity pattern of the analytes was determined and showed the order of sensitivity increased with increased alkyl chain length (MDA < MDMA < MDEA). The overall performance of the sensor, working range, precision and sensitivity demonstrate its usefulness for rapid and direct measurement of methylenedioxy analogues of ecstasy in saliva and urine. The sensor has better specificity than any previous method for ecstasy, with greater sensitivity than ELISA methods, is less expensive/assay with an "easier to use" format than previous methods. The detection works in saliva or urine, eliminating requirement of blood sampling, with improved precision. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:333 / 339
页数:7
相关论文
共 50 条
  • [41] Celiac disease detection using a transglutaminase electrochemical immunosensor fabricated on nanohybrid screen-printed carbon electrodes
    Neves, Marta M. P. S.
    Gonzalez-Garcia, Maria Begona
    Nouws, Henri P. A.
    Costa-Garcia, Agustin
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 95 - 100
  • [42] A disposable reagentless screen-printed amperometric biosensor for the measurement of alcohol in beverages
    Sprules, SD
    Hartley, IC
    Wedge, R
    Hart, JP
    Pittson, R
    ANALYTICA CHIMICA ACTA, 1996, 329 (03) : 215 - 221
  • [43] Amperometric determination of sulfite using screen-printed electrodes modified with metallic nanoparticles
    Begoña Molinero-Abad
    María Asunción Alonso-Lomillo
    Olga Domínguez-Renedo
    María Julia Arcos-Martínez
    Microchimica Acta, 2013, 180 : 1351 - 1355
  • [44] Amperometric determination of omeprazole on screen-printed electrodes using batch injection analysis
    Stefano, Jessica S.
    Tormin, Thiago F.
    da Silva, Jamilia P.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    MICROCHEMICAL JOURNAL, 2017, 133 : 398 - 403
  • [45] Electrochemical bioassay for the detection of TNF-α using magnetic beads and disposable screen-printed array of electrodes
    Bettazzi, Francesca
    Enayati, Laleh
    Campos Sanchez, Inmaculada
    Motaghed, Robabeh
    Mascini, Marco
    Palchetti, Ilaria
    BIOANALYSIS, 2013, 5 (01) : 11 - 19
  • [46] Screen-printed disposable electrodes: Pharmaceutical applications and recent developments
    Mohamed, Heba M.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 82 : 1 - 11
  • [47] Voltammetric determination of Rutin at Screen-Printed carbon disposable electrodes
    de Oliveira-Roberth, Aline
    Santos, Diego I. V.
    Cordeiro, Diogo D.
    Lino, Fernando M. de A.
    Bara, Maria T. F.
    Gil, Eric de S.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (05): : 1609 - 1616
  • [48] Amperometric determination of sulfite using screen-printed electrodes modified with metallic nanoparticles
    Molinero-Abad, Begona
    Asuncion Alonso-Lomillo, Maria
    Dominguez-Renedo, Olga
    Julia Arcos-Martinez, Maria
    MICROCHIMICA ACTA, 2013, 180 (13-14) : 1351 - 1355
  • [49] A disposable amperometric enzyme immunosensor for rapid detection of Vibrio parahaemolyticus in food based on agarose/Nano-Au membrane and screen-printed electrode
    Zhao, Guangying
    Xing, Fengfeng
    Deng, Shaoping
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (06) : 1263 - 1268
  • [50] Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens
    Vasilescu, Alina
    Nunes, Gilvanda
    Hayat, Akhtar
    Latif, Usman
    Marty, Jean-Louis
    SENSORS, 2016, 16 (11)