A disposable reagentless screen-printed amperometric biosensor for the measurement of alcohol in beverages

被引:53
|
作者
Sprules, SD
Hartley, IC
Wedge, R
Hart, JP
Pittson, R
机构
[1] UNIV W ENGLAND,FAC SCI APPL,BRISTOL BS16 1QY,AVON,ENGLAND
[2] GWENT ELECT MAT LTD,PONTYPOOL NP4 0HZ,GWENT,WALES
关键词
screen-printing; biosensors; amperometry; ethanol; trehalose;
D O I
10.1016/0003-2670(96)00121-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable sensor strip was fabricated by a screen-printing procedure. This consisted of a Meldola's blue modified carbon working electrode and a Ag/AgCl combined reference/counter electrode printed alongside each other on a PVC substrate. The working electrode was coated with a mixture containing alcohol dehydrogenase (10 units) and NAD(+) (60 mu g) to produce a sensor that would respond to alcohol. In order to improve the stability of the enzyme system the non-reducing sugar known as trehalose was incorporated into the enzyme/cofactor coating. Without trehalose the response to ethanol decreased dramatically over a period of 21 days, and no detectable signal was detected on the last day. With trehalose, 90% activity was observed 49 days after production. Using amperometry in stirred solution a calibration graph exhibited linearity up to a concentration of 35 x 10(-3) mol dm(-3) ethanol. The biosensor was used to determine the concentration of ethanol in a commercial gin sample and good agreement was obtained between the calculated value and that obtained by a recommended gas chromatographic procedure. Butan-1-ol > propan-1-ol > propan-2-ol also gave responses.
引用
收藏
页码:215 / 221
页数:7
相关论文
共 50 条
  • [1] FABRICATION AND CHARACTERIZATION OF A SCREEN-PRINTED, DISPOSABLE, AMPEROMETRIC CHOLESTEROL BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    [J]. ANALYST, 1994, 119 (11) : 2331 - 2336
  • [2] Studies towards a disposable screen-printed amperometric biosensor for progesterone
    Hart, JP
    Pemberton, RM
    Luxton, R
    Wedge, R
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (11): : 1113 - 1121
  • [3] Disposable screen-printed biosensor for transcutaneous oxygen measurement
    Lam, YZ
    Atkinson, J
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (12) : 2074 - 2081
  • [4] A screen-printed disposable biosensor for selective determination of putrescine
    Henao-Escobar, Wilder
    Dominguez-Renedo, Olga
    Asuncion Alonso-Lomillo, Maria
    Julia Arcos-Martinez, Maria
    [J]. MICROCHIMICA ACTA, 2013, 180 (7-8) : 687 - 693
  • [5] A screen-printed disposable biosensor for selective determination of putrescine
    Wilder Henao-Escobar
    Olga Domínguez-Renedo
    María Asunción Alonso-Lomillo
    María Julia Arcos-Martínez
    [J]. Microchimica Acta, 2013, 180 : 687 - 693
  • [6] Amperometric bienzyme screen-printed biosensor for the determination of leucine
    Labroo, Pratima
    Cui, Yue
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (01) : 367 - 372
  • [7] Amperometric bienzyme screen-printed biosensor for the determination of leucine
    Pratima Labroo
    Yue Cui
    [J]. Analytical and Bioanalytical Chemistry, 2014, 406 : 367 - 372
  • [8] Disposable carbon nanotube modified screen-printed biosensor for amperometric detection of organophosphorus pesticides and nerve agents
    Lin, YH
    Lu, F
    Wang, J
    [J]. ELECTROANALYSIS, 2004, 16 (1-2) : 145 - 149
  • [9] Flow-injection detector incorporating a screen-printed disposable amperometric biosensor for monitoring organophosphate pesticides
    Rippeth, JJ
    Gibson, TD
    Hart, JP
    Hartley, IC
    Nelson, G
    [J]. ANALYST, 1997, 122 (11) : 1425 - 1429
  • [10] Amperometric determination of phosphoglucomutase activity with a bienzyme screen-printed biosensor
    Cui, Y
    Barford, JP
    Renneberg, R
    [J]. ANALYTICAL BIOCHEMISTRY, 2006, 354 (01) : 162 - 164