A novel method for simultaneous 3D B1 and T1 mapping: the method of slopes (MoS)

被引:21
|
作者
Chavez, Sofia [1 ]
Stanisz, Greg J. [2 ,3 ]
机构
[1] Ctr Addict & Mental Hlth, Res Imaging Ctr, Toronto, ON M5T 1R8, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
基金
加拿大健康研究院;
关键词
B1; inhomogeneities; T1; mapping; SPGR; flip angle; spoiled-gradient-echo; RF-FIELD INHOMOGENEITIES; IN-VIVO; T-2; RELAXATION; STEADY-STATE; ACCURATE; RADIOFREQUENCY; MRI;
D O I
10.1002/nbm.2769
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel three-dimensional simultaneous B1 and T1 mapping method is introduced: the method of slopes (MoS). The linearity of the spoiled gradient recalled echo (SPGR) signal vs flip angle relation is exploited: B1 mapping is achieved by a two-point extrapolation to signal null with a correction scheme while T1 mapping uses the slopes of the SPGR signal vs flip angle curves near the origin and near the signal null. This new method improves upon the existing variable flip angle (VFA) T1-mapping method in that (i) consistency between B1 and T1 maps is ensured (ii) the sampling scheme is T1-independent (iii) the noise bias and singularity, associated with using a linear form for the SPGR signal equation, is eliminated by using the full equation. The method is shown to yield accurate and robust results via simulations. Initial estimates of B1 and T1 values are obtained from three data points via simple computations and straight line approximations. Initial estimates of B1 values, for a range of values, are shown to be accurate due to the proposed B1 correction scheme. The accuracy and robustness of T1 values is achieved via a non-linear fitting algorithm which includes a fourth data point sampled at high SNR. The MoS was validated by comparing resulting B1 and T1 maps with those obtained using other standard methods. Finally, the ability to obtain brain B1 and T1 maps using the MoS was demonstrated by in vivo experiments. The MoS is expected to perform well on other motion-free anatomical regions as well. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:1043 / 1055
页数:13
相关论文
共 50 条
  • [1] B1 and T1 Mapping of the Breast with a Reference Tissue Method
    Pineda, Federico D.
    Medved, Milica
    Fan, Xiaobing
    Karczmar, Gregory S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1565 - 1573
  • [2] Alternating Look-Locker for quantitative T1, T1? and B1 3D MRI mapping
    Wu, Lin
    Carchi, Chris
    Michaeli, Shalom
    Mangia, Silvia
    Idiyatullin, Djaudat
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2023, 91 (01) : 149 - 161
  • [3] Extended Multi-Flip-Angle B1 Mapping: A 3D Mapping Method for Inhomogeneous B1 Fields
    Weber, Hans
    Paul, Dominik
    Elverfeldt, Dominik V.
    Hennig, Juergen
    Zaitsev, Maxim
    [J]. CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2010, 37B (04) : 203 - 214
  • [4] Silent T1 mapping using the variable flip angle method with B1 correction
    Ljungberg, Emil
    Wood, Tobias
    Solana, Ana Beatriz
    Kolind, Shannon
    Williams, Steven C. R.
    Wiesinger, Florian
    Barker, Gareth J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 813 - 824
  • [5] A fast 3D Look-Locker method for volumetric T1 mapping
    Henderson, E
    McKinnon, G
    Lee, TY
    Rutt, BK
    [J]. MAGNETIC RESONANCE IMAGING, 1999, 17 (08) : 1163 - 1171
  • [6] Optimal flip angles for in vivo liver 3D T1 mapping and B1+ mapping at 3T
    Belsley, Gabriela
    Tyler, Damian J.
    Robson, Matthew D.
    Tunnicliffe, Elizabeth M.
    [J]. Magnetic Resonance in Medicine, 2023, 90 (03): : 950 - 962
  • [7] 3D Myocardial T1 Mapping at 3T Using Variable Flip Angle Method: Pilot Study
    Clique, Helene
    Cheng, Hai-Ling Margaret
    Marie, Pierre-Yves
    Felblinger, Jacques
    Beaumont, Marine
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 823 - 829
  • [8] 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn
    Regatte, Ravinder R.
    [J]. NMR IN BIOMEDICINE, 2022, 35 (12)
  • [9] Fast B1 Mapping Based on Double-Angle Method with T1 Correction Using Standard Pulse Sequence
    Ishimori, Yoshiyuki
    Shimanuki, Takeshi
    Kobayashi, Tomoya
    Monma, Masahiko
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 93 - 98
  • [10] Dynamic range of the T1 farm single shot T1 mapping method
    Mckenzie, CA
    Pereira, RS
    Prato, FS
    Chen, Z
    Drost, DJ
    [J]. RADIOLOGY, 1998, 209P : 357 - 357