B1 and T1 Mapping of the Breast with a Reference Tissue Method

被引:24
|
作者
Pineda, Federico D. [1 ]
Medved, Milica [1 ]
Fan, Xiaobing [1 ]
Karczmar, Gregory S. [1 ]
机构
[1] Univ Chicago, Dept Radiol, MC2026,5841 South Maryland Ave, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
B-1; map; reference tissue method; quantitative breast imaging; T-1; mapping; PARALLEL RADIOFREQUENCY EXCITATION; STEADY-STATE; 3.0; T; MRI; FIELD; 3T; INHOMOGENEITY; RELAXATION; SEQUENCES; DIAGNOSIS;
D O I
10.1002/mrm.25751
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a method for mapping the B1 field using a reference signal from a tissue with known T1. Methods: Flip angle correction factors were calculated in a region with a known "gold standard" T1; by comparing T1 values from a variable flip angle (VFA) sequence to the "gold standard" and correcting the value of the Ernst angle. The resulting partial B1 map was interpolated for all other regions. In the breast, fat is an ideal reference tissue because its T1 is spatially homogeneous and interpatient variability is low. This method was tested with scans of phantoms and patients (n = 4) on a 3T magnet. The performance of the method was evaluated by comparing the results of VFA T1 mapping with and without B1 correction to inversion recovery (IR) T1 maps. Results: Phantom data determined that a linear inverse distance weighted interpolation accurately recovered the full B1 map. Use of interpolated maps to correct the VFA data in vivo, reduced the average difference in the T1 of parenchyma between VFA and IR results from 58% to 8%. Conclusion: This proof-of-principle study showed that it is possible to recover a full and accurate map of the B1 field in the breast by using a reference tissue (fat) with an accurately measured T1. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 50 条
  • [1] Silent T1 mapping using the variable flip angle method with B1 correction
    Ljungberg, Emil
    Wood, Tobias
    Solana, Ana Beatriz
    Kolind, Shannon
    Williams, Steven C. R.
    Wiesinger, Florian
    Barker, Gareth J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 813 - 824
  • [2] A novel method for simultaneous 3D B1 and T1 mapping: the method of slopes (MoS)
    Chavez, Sofia
    Stanisz, Greg J.
    [J]. NMR IN BIOMEDICINE, 2012, 25 (09) : 1043 - 1055
  • [3] Alternating Look-Locker for quantitative T1, T1? and B1 3D MRI mapping
    Wu, Lin
    Carchi, Chris
    Michaeli, Shalom
    Mangia, Silvia
    Idiyatullin, Djaudat
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2023, 91 (01) : 149 - 161
  • [4] Mapping tissue water T1 in the liver using the MOLLI T1 method in the presence of fat, iron and B0 inhomogeneity
    Mozes, Ferenc E.
    Tunnicliffe, Elizabeth M.
    Moolla, Ahmad
    Marjot, Thomas
    Levick, Christina K.
    Pavlides, Michael
    Robson, Matthew D.
    [J]. NMR IN BIOMEDICINE, 2019, 32 (02)
  • [5] CRAMER RAO BOUND ANALYSIS OF JOINT B1/T1 MAPPING METHODS IN MRI
    Funai, Amanda
    Fessler, Jeffrey A.
    [J]. 2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 712 - 715
  • [6] Optimized and combined T1 and B1 mapping technique for fast and accurate T1 quantification in contrast-enhanced abdominal MRI
    Treier, Reto
    Steingoetter, Andreas
    Fried, Michael
    Schwizer, Werner
    Boesiger, Peter
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 568 - 576
  • [7] The Tissue Issue T1 Mapping and the Myocardium
    Kramer, Christopher M.
    Chandrashekhar, Y.
    Narula, Jagat
    [J]. JACC-CARDIOVASCULAR IMAGING, 2016, 9 (01) : 88 - 90
  • [8] Fast B1 Mapping Based on Double-Angle Method with T1 Correction Using Standard Pulse Sequence
    Ishimori, Yoshiyuki
    Shimanuki, Takeshi
    Kobayashi, Tomoya
    Monma, Masahiko
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 93 - 98
  • [9] T1 Corrected B1 Mapping Using Multi-TR Gradient Echo Sequences
    Voigt, Tobias
    Nehrke, Kay
    Doessel, Olaf
    Katscher, Ulrich
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) : 725 - 733
  • [10] Dynamic range of the T1 farm single shot T1 mapping method
    Mckenzie, CA
    Pereira, RS
    Prato, FS
    Chen, Z
    Drost, DJ
    [J]. RADIOLOGY, 1998, 209P : 357 - 357