Redistribution of the neurosensory retina in inferior limited macular translocation: an evaluation using image registration

被引:1
|
作者
Denion, Eric
Ordonez, John-Richard
Klein, Jean-Claude
Glacet-Bernard, Agnes
Walter, Thomas
Caputo, Georges
机构
[1] Fdn Ophtalmol Adolphe Rothschild, Serv Ophtalmol Pediat, F-75019 Paris, France
[2] Ecole Natl Super Mines, Ctr Morphol Math, F-77305 Fontainebleau, France
[3] Ctr Hosp Intercommunal, Serv Ophtalmol, F-94000 Creteil, France
关键词
redistribution of the neurosensory retina; inferior limited macular translocation; image registration; age-related macular degeneration; quantization;
D O I
10.1007/s00417-006-0408-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background The present work aims to demonstrate the role of redistribution of the neurosensory retina (RNR)-that is, retinal tissue stretching and compression-in inferior limited macular translocation (LMT), to perform displacement mapping all over the area centralis, and to try and improve displacement evaluation precision. Methods Using piecewise linear image registration (through Matlab) on indocyanine green angiographic frames, we have evaluated the deformation (on both the retinal and choroido-scleral layer) of a pre-operative grid superimposed on the area centralis, plotted displacement vectors all over the area centralis, and calculated a scale ratio between pre- and post-operative frames. The scale ratio tests whether or not the same physical distance is represented by the same distance on these frames. Results The choroido-scleral layer is not deformed following surgery. The retinal layer shows areas of stretching and compression, demonstrating the RNR. Displacement vectors feature a rotating pattern around the optic disk (except if a macular fold exists) and a positive naso-temporal gradient. The median scale ratio is 3.8% (2.5% to 5.8%). Conclusions LMT involves RNR accounting for inferior retinal displacement, despite the supposedly limited internal scleral shortening. Our study confirms that the optic disk temporal edge is the displacement axis (except if a macular fold exists). Our method, unaffected by a non-zero scale ratio, provides more precision than previously published.
引用
收藏
页码:437 / 442
页数:6
相关论文
共 50 条
  • [41] Performance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastases
    Han, Min Cheol
    Kim, Jihun
    Hong, Chae-Seon
    Chang, Kyung Hwan
    Han, Su Chul
    Park, Kwangwoo
    Kim, Dong Wook
    Kim, Hojin
    Chang, Jee Suk
    Kim, Jina
    Kye, Sunsuk
    Park, Ryeong Hwang
    Chung, Yoonsun
    Kim, Jin Sung
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2022, 21
  • [42] Computer-aided evaluation system for Parkinson's disease using image registration and labeling
    Lee, Jiann-Der
    Chen, Cheng-Wei
    Huang, Chung-Hsien
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 844 - 847
  • [43] Evaluation of Macular Neurovasculature and Choroidal Blood Flow Following Inferior Oblique Myectomy Using Optical Coherence Tomography Angiography
    Javaheri, Zeinab Hashemi
    Sabermoghaddam, Ali Akbar
    Abrishami, Mojtaba
    Kiarudi, Mohammad Yaser
    Shariati, Mehrdad Motamed
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2024, 61 (04) : 235 - 244
  • [44] THE STUDY OF EVALUATION TO RELATIONSHIP BETWEEN THE INFERIOR ALVEOLAR NERVE AND THE MANDIBULAR THIRD MOLAR BY USING RADIOGRAPHIC IMAGE
    Kim, Jong-Hyoup
    Gu, Hong
    An, Jin-Suk
    Kook, Min-Suk
    Park, Hong-Ju
    Oh, Hee-Kyun
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2006, 32 (05) : 464 - 473
  • [45] The Effect of Utilizing Image Registration Software on Central Macular Thickness Reproducibility Using Commercially Available Spectral Domain Optical Coherence Tomography
    Sedeek, R. W.
    Redenbo, E.
    Chandra, K.
    Park, S. S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [46] Non-Coplanar Cone Beam CT Reconstruction With Limited Angle of Projections Using Rigid Image Registration Facilitated Prior Image Constrained Compressed Sensing
    Meng, B.
    Li, R.
    Han, B.
    Chen, J.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S146 - S146
  • [47] Non-Coplanar Cone Beam CT Reconstruction with Limited Angle of Projections Using Rigid Image Registration Facilitated Prior Image Constrained Compressed Sensing
    Meng, B.
    Li, R.
    Han, B.
    Cheng, J.
    Xing, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [48] Evaluation of performance of pelvic CT-MR deformable image registration using two software programs
    Ishida, Tomoya
    Kadoya, Noriyuki
    Tanabe, Shunpei
    Ohashi, Haruna
    Nemoto, Hikaru
    Dobashi, Suguru
    Takeda, Ken
    Jingu, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1076 - 1082
  • [49] Quality evaluation of compressed panoramic images constructed using MPEG-7-based image registration
    Glowacz, Andrzej
    Grega, Michal
    Romaniak, Piotr
    Leszczuk, Mikolaj
    2008 NEXT GENERATION INTERNET NETWORKS AND 4TH EURONGI CONFERENCE ON NEXT GENERATION INTERNET NETWORKS, PROCEEDINGS, 2008, : 167 - 172
  • [50] B-spline deformable image registration algorithm evaluation using numerical and physical phantom.
    Badey, A.
    Tolsa, S.
    Bodez, V.
    Khamphan, C.
    Jaegle, E.
    Alayrach, M. E.
    Martinez, P.
    Garcia, R.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1133 - S1134