Redistribution of the neurosensory retina in inferior limited macular translocation: an evaluation using image registration

被引:1
|
作者
Denion, Eric
Ordonez, John-Richard
Klein, Jean-Claude
Glacet-Bernard, Agnes
Walter, Thomas
Caputo, Georges
机构
[1] Fdn Ophtalmol Adolphe Rothschild, Serv Ophtalmol Pediat, F-75019 Paris, France
[2] Ecole Natl Super Mines, Ctr Morphol Math, F-77305 Fontainebleau, France
[3] Ctr Hosp Intercommunal, Serv Ophtalmol, F-94000 Creteil, France
关键词
redistribution of the neurosensory retina; inferior limited macular translocation; image registration; age-related macular degeneration; quantization;
D O I
10.1007/s00417-006-0408-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background The present work aims to demonstrate the role of redistribution of the neurosensory retina (RNR)-that is, retinal tissue stretching and compression-in inferior limited macular translocation (LMT), to perform displacement mapping all over the area centralis, and to try and improve displacement evaluation precision. Methods Using piecewise linear image registration (through Matlab) on indocyanine green angiographic frames, we have evaluated the deformation (on both the retinal and choroido-scleral layer) of a pre-operative grid superimposed on the area centralis, plotted displacement vectors all over the area centralis, and calculated a scale ratio between pre- and post-operative frames. The scale ratio tests whether or not the same physical distance is represented by the same distance on these frames. Results The choroido-scleral layer is not deformed following surgery. The retinal layer shows areas of stretching and compression, demonstrating the RNR. Displacement vectors feature a rotating pattern around the optic disk (except if a macular fold exists) and a positive naso-temporal gradient. The median scale ratio is 3.8% (2.5% to 5.8%). Conclusions LMT involves RNR accounting for inferior retinal displacement, despite the supposedly limited internal scleral shortening. Our study confirms that the optic disk temporal edge is the displacement axis (except if a macular fold exists). Our method, unaffected by a non-zero scale ratio, provides more precision than previously published.
引用
收藏
页码:437 / 442
页数:6
相关论文
共 50 条
  • [21] Image registration for limited-view photoacoustic imaging using two linear array transducers
    Shu, Weihang
    Ai, Min
    Salcudean, Tim
    Rohling, Robert
    Abolmaesumi, Purang
    Tang, Shuo
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2015, 2015, 9323
  • [22] Brain Stroke Evaluation from Multi-image Modalities Using Image Registration and SegmentationTechniques
    Jiang, Ching-Fen
    Huang, Wan-Chi
    INTELLIGENT SYSTEMS AND APPLICATIONS (ICS 2014), 2015, 274 : 1069 - 1076
  • [23] Inferior Alveolar Nerve Mobilization Using Ultrasonic Surgery With Crestal Approach Technique, Followed by Immediate Implant Insertion: Evaluation of Neurosensory Disturbance
    Mavriqi, Luan
    Mortellaro, Carmen
    Scarano, Antonio
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (05) : 1209 - 1211
  • [24] Evaluation of Lung Hysteresis using a Bifurcation Tracking Code and Deformable Image Registration
    Moseley, J. L.
    Hunter, S. F.
    Al-Mayah, A.
    Brock, K. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S43 - S43
  • [25] Evaluation of Diffeomorphic Demons Algorithm for Deformable Image Registration Using Virtual Phantom
    Reiazi, R.
    Mohammadi, R.
    Mahdavi, S. R.
    MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [26] Image registration, parameter tuning and approximate function evaluation, using the genetic algorithm and digital image warping
    Pagliari, GM
    Greene, JR
    AFRICON '96 - 1996 IEEE AFRICON : 4TH AFRICON CONFERENCE IN AFRICA, VOLS I & II: ELECTRICAL ENERGY TECHNOLOGY; COMMUNICATION SYSTEMS; HUMAN RESOURCES, 1996, : 536 - 541
  • [27] Elastic image registration of diagnostic brain MR and limited view intra operative mr using mutual information
    Devabhaktuni, S
    Loncaric, S
    Schulder, M
    PROCEEDINGS OF THE IEEE 29TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2003, : 104 - 105
  • [28] Optimal Hyperparameter Selection in Deformable Image Registration using Information Criterion and Band-Limited Modal Reconstruction
    Heiselman, Jon S.
    Ringel, Morgan J.
    Chakraborty, Jayasree
    Jarnagin, William R.
    Miga, Michael I.
    IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, MEDICAL IMAGING 2024, 2024, 12928
  • [29] Extracranial image registration using mutual information, limited field of view data and piecewise-rigid transformations
    Kessler, M
    MEDICAL PHYSICS, 2002, 29 (06) : 1340 - 1340
  • [30] Accuracy Evaluation of Dose Warping Using Deformable Image Registration in Carbon Ion Therapy
    Miyasaka, Yuya
    Souda, Hikaru
    Chai, Hongbo
    Ishizawa, Miyu
    Sato, Hiraku
    Iwai, Takeo
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2025, 15