Analysis of Compound-Specific Chlorine Stable Isotopes of Vinyl Chloride by Continuous Flow-Isotope Ratio Mass Spectrometry (FC-IRMS)

被引:14
|
作者
Shouakar-Stash, Orfan [1 ]
Frape, S. K. [1 ]
Aravena, R. [1 ]
Gargini, A. [2 ]
Pasini, M. [2 ]
Drimmie, R. J. [1 ]
机构
[1] Univ Waterloo, Dept Earth & Environm Sci, Waterloo, ON N2L 3G1, Canada
[2] Univ Ferrara, Dept Earth Sci, I-44100 Ferrara, Italy
关键词
vinyl chloride (VC); compound-specific chlorine stable isotopes; groundwater; CARBON;
D O I
10.1080/15275920903347628
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new method for determining compound-specific chlorine stable isotope was developed for vinyl chloride (VC). The analysis is carried out on a continuous flow-isotope ratio mass spectrometer (CF-IRMS) with special collectors for m/z 64 and 62. The precision of this technique is better than +/- 0.16 parts per thousand (1 sigma) for pure phase gas injection and headspace solid phase microextraction (SPME) injection. The new methodology was tested in a confined sandy aquifer contaminated with VC located near the city of Ferrara, northern Italy. The VC isotopic signatures (37Cl and 13C) showed that the VC is not a primary manufactured compound and is a byproduct of production of petrochemicals in the Ferrara region during the 1970s and 1980s. The isotope data also suggested VC is attenuated by biodegradation along the groundwater flow system. The development of compound-specific isotope analysis (CSIA) for VC offers a new tool for fingerprinting sources and processes that affect VC in groundwater.
引用
收藏
页码:299 / 306
页数:8
相关论文
共 50 条
  • [21] Optimization of compound-specific chlorine stable isotope analysis of chloroform using the Taguchi design of experiments
    Asfaw, Berhane Abrha
    Sakaguchi-Soeder, Kaori
    Bernstein, Anat
    Siebner, Hagar
    Schuth, Christoph
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (23)
  • [22] Compound-Specific Chlorine Isotope Analysis of Tetrachloromethane and Trichloromethane by Gas Chromatography-Isotope Ratio Mass Spectrometry vs Gas Chromatography-Quadrupole Mass Spectrometry: Method Development and Evaluation of Precision and Trueness
    Heckel, Benjamin
    Rodriguez-Fernandez, Diana
    Torrento, Clara
    Meyer, Armin
    Palau, Jordi
    Domenech, Cristina
    Rosen, Monica
    Soler, Albert
    Hunkeler, Daniel
    Elsner, Martin
    ANALYTICAL CHEMISTRY, 2017, 89 (06) : 3411 - 3420
  • [23] Triple oxygen stable isotope analysis of nitrite measured using continuous flow isotope ratio mass spectrometry *
    Walters, Wendell W.
    Hastings, Meredith G.
    METHODSX, 2023, 11
  • [24] Memory Effects in Compound-Specific D/H Analysis by Gas Chromatography/Pyrolysis/Isotope-Ratio Mass Spectrometry
    Wang, Ying
    Sessions, Alex L.
    ANALYTICAL CHEMISTRY, 2008, 80 (23) : 9162 - 9170
  • [25] Derivatization of Levoglucosan for Compound-Specific δ13C Analysis by Gas Chromatography/Combustion/Isotope Ratio Mass Spectrometry
    Zhang, Dongling
    Swe Aung, Swe
    Han, Yong
    Zhang, Yanlin
    Chen, Yingjun
    Li, Hongli
    Yu, Feifei
    Wang, Yangjun
    Feng, Jialiang
    Wang, Wu
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 2020 (2020)
  • [26] Online quantification and compound-specific stable isotopic analysis of black carbon in environmental matrices via liquid chromatography-isotope ratio mass spectrometry
    Wagner, Sasha
    Brandes, Jay
    Goranov, Aleksandar I.
    Drake, Travis W.
    Spencer, Robert G. M.
    Stubbins, Aron
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2017, 15 (12): : 995 - 1006
  • [27] Substantial peak size effect on compound-specific δD values analyzed on isotope ratio mass spectrometry
    Liu, Hu
    Cao, Yunning
    Hu, Jing
    Liu, Zhonghui
    Liu, Weiguo
    CHEMICAL GEOLOGY, 2022, 590
  • [28] Bulk and compound-specific stable isotope ratio analysis for authenticity testing of organically grown tomatoes
    Bontempo, Luana
    van Leeuwen, Katryna A.
    Paolini, Mauro
    Laursen, Kristian Holst
    Micheloni, Cristina
    Prenzler, Paul D.
    Ryan, Danielle
    Camin, Federica
    FOOD CHEMISTRY, 2020, 318
  • [29] Helium-flushed sheathed nickel tube reactor for continuous flow oxygen stable isotope compound-specific analysis
    Johnson, Carl G.
    Galy, Valier V.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2022, 36 (08)
  • [30] Oxygen isotope analysis of silicates using continuous flow isotope ratio mass spectrometry
    Kingston, A. W.
    Weis, D.
    Francois, R.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A474 - A474