The Sensitivity of Gamma Index to Detect MLC Positioning Errors Using Varian EPID and ArcCHECK for Patient-Specific VMAT QA

被引:0
|
作者
Maraghechi, B. [1 ]
Darko, J. [1 ,2 ,3 ]
Davis, J. [2 ]
Mitchell, N. [2 ]
Shah, M. [2 ]
Fleck, A. [1 ,3 ]
Osei, E. [1 ,2 ,3 ]
机构
[1] Grand River Reg Canc Ctr, Kitchener, ON, Canada
[2] Univ Waterloo, Waterloo, ON, Canada
[3] Univ Guelph, Guelph, ON, Canada
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-T
引用
收藏
页码:2887 / 2887
页数:1
相关论文
共 50 条
  • [21] Gamma index comparison of three VMAT QA systems and evaluation of their sensitivity to delivery errors
    Vieillevigne, Laure
    Molinier, Jeremy
    Brun, Thomas
    Ferrand, Regis
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 720 - 725
  • [22] Intercomparison of Patient-Specific IMRT QA Devices for Small-Field, Stereotactic VMAT Treatments Using Gamma Index Analysis
    Alvarez, D.
    Wieczorek, D.
    Mishra, V.
    Gutierrez, A.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2957 - 2957
  • [23] Patient-specific QA for CyberKnife MLC plans using Monte Carlo
    Mackeprang, P. H.
    Vuong, D.
    Volken, W.
    Henzen, D.
    Schmidhalter, D.
    Malthaner, M.
    Mueller, S.
    Frei, D.
    Aebersold, D. M.
    Fix, M. K.
    Manser, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S791 - S791
  • [24] On the Evaluation of Patient-Specific IMRT QA Using EPID, Dynalog Files, and Patient Anatomy
    Defoor, D.
    Mavroidis, P.
    Gutierrez, A.
    Papanikolaou, N.
    Stathakis, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S885 - S885
  • [25] A synthesized gamma distribution-based patient-specific VMAT QA using a generative adversarial network
    Matsuura, Takaaki
    Kawahara, Daisuke
    Saito, Akito
    Yamada, Kiyoshi
    Ozawa, Shuichi
    Nagata, Yasushi
    [J]. MEDICAL PHYSICS, 2023, 50 (04) : 2488 - 2498
  • [26] A Synthesized Gamma Map-Based Patient-Specific VMAT QA Using a Generative Adversarial Network
    Matsuura, T.
    Kawahara, D.
    Saito, A.
    Yamada, K.
    Ozawa, S.
    Nagata, Y.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E897 - E898
  • [27] The effect of MLC positioning errors on plan dose distribution and gamma analysis using EPID dosimetry
    Maraghechi, Borna
    Davis, Jack
    Mitchell, Nicholas
    Shah, Meera
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    [J]. MEDICAL PHYSICS, 2017, 44 (08) : 4377 - 4378
  • [28] A model-based 3D patient-specific pre-treatment QA method for VMAT using the EPID
    McCowan, P. M.
    Asuni, G.
    van Beek, T.
    van Uytven, E.
    Kujanpaa, K.
    McCurdy, B. M. C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (04): : 1600 - 1612
  • [29] The relationship of MU density and gamma passing rate in patient-specific QA using EPID and Delta4
    Li, D.
    Li, X.
    Zhen, X.
    Zhang, Z.
    Wang, Y.
    Liu, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1333 - S1335
  • [30] Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms
    Sterling, D.
    Ehler, E.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3357 - 3357