A synthesized gamma distribution-based patient-specific VMAT QA using a generative adversarial network

被引:6
|
作者
Matsuura, Takaaki [1 ,2 ]
Kawahara, Daisuke [2 ,4 ]
Saito, Akito [3 ]
Yamada, Kiyoshi [1 ]
Ozawa, Shuichi [1 ,2 ]
Nagata, Yasushi [1 ,2 ]
机构
[1] Hiroshima High Precis Radiotherapy Canc Ctr, Hiroshima, Japan
[2] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Radiat Oncol, Hiroshima, Japan
[3] Hiroshima Univ Hosp, Dept Radiat Oncol, Hiroshima, Japan
[4] Hiroshima Univ, Grad Sch Biomed & Hlth Sci, Dept Radiat Oncol, 1-2-3 Kasumi, Hiroshima, Hiroshima 7348551, Japan
关键词
deep learning; gamma distribution; gamma passing rate; GAN; QUALITY-ASSURANCE; PLAN COMPLEXITY; CLINICAL IMPLEMENTATION; INDEX ANALYSIS; PASSING RATE; IMRT; ERRORS; MODEL;
D O I
10.1002/mp.16210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundArtificial intelligence (AI)-based gamma passing rate (GPR) prediction has been proposed as a time-efficient virtual patient-specific QA method for the delivery of volumetric modulation arc therapy (VMAT). However, there is a limitation that the GPR value loses the locational information of dose accuracy. PurposeThe objective was to predict the failing points in the gamma distribution and the GPR using a synthesized gamma distribution of VMAT QA with a deep convolutional generative adversarial network (GAN). MethodsThe fluence maps of 270 VMAT beams for prostate cancer were measured using an electronic portal imaging device and analyzed using gamma evaluation with 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances. The 270 gamma distributions were divided into two datasets: 240 training datasets for creating a model and 30 test datasets for evaluation. The image prediction network for the fluence maps calculated by the treatment planning system (TPS) to the gamma distributions was created using a GAN. The sensitivity, specificity, and accuracy of detecting failing points were evaluated using measured and synthesized gamma distributions. In addition, the difference between measured GPR (mGPR) and predicted GPR (pGPR) values calculated from the synthesized gamma distributions was evaluated. ResultsThe root mean squared errors between mGPR and pGPR were 1.0%, 2.1%, 3.5%, and 3.6% for the 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances, respectively. The accuracies for detecting failing points were 98.9%, 96.9%, 94.7%, and 93.7% for 3%/2-mm, 2%/1-mm, 1%/1-mm, and 1%/0.5-mm tolerances, respectively. The sensitivity and specificity were the highest for 1%/0.5-mm and 3%/2-mm tolerances, which were 82.7% and 99.6%, respectively. ConclusionsWe developed a novel system using a GAN to generate a synthesized gamma distribution-based patient-specific VMAT QA. The system is promising from the point of view of quality assurance in radiotherapy because it shows high performance and can detect failing points.
引用
收藏
页码:2488 / 2498
页数:11
相关论文
共 50 条
  • [1] A Synthesized Gamma Map-Based Patient-Specific VMAT QA Using a Generative Adversarial Network
    Matsuura, T.
    Kawahara, D.
    Saito, A.
    Yamada, K.
    Ozawa, S.
    Nagata, Y.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E897 - E898
  • [2] VMAT Commissioning and Patient-Specific QA Using MatriXX Phantom
    Bao, A.
    Geis, P.
    Zheng, Y.
    Pereira, G.
    Petchler, N. Kuc
    Elconin, J.
    Machtay, M.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E273 - E274
  • [3] Anatomy-based, patient-specific VMAT QA using EPID or MLC log files
    Defoor, Dewayne L.
    Vazquez-Quino, Luis A.
    Mavroidis, Panayiotis
    Papanikolaou, Nikos
    Stathakis, Sotirios
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 206 - 215
  • [4] Complexity metric as a complement to measurement based IMRT/VMAT patient-specific QA
    Gotstedt, J.
    Hauer, A. Karlsson
    Back, A.
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [5] An Enhanced Gamma Index for Patient Specific VMAT QA
    Patel, R.
    Sethi, A.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3272 - 3272
  • [6] Clinical Implementation of Deep Learning-Based VMAT Patient-Specific QA
    Yang, X.
    Wang, L.
    Li, D.
    Guo, Y.
    Li, Y.
    Guan, Y.
    Wu, X.
    Xu, S.
    Zhang, S.
    Chan, M.
    Yang, R.
    Geng, L.
    Sui, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [7] Unifying gamma passing rates in patient-specific QA for VMAT lung cancer treatment based on data assimilation
    Ono, Tomohiro
    Adachi, Takanori
    Hirashima, Hideaki
    Iramina, Hiraku
    Kishi, Noriko
    Matsuo, Yukinori
    Nakamura, Mitsuhiro
    Mizowaki, Takashi
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024,
  • [8] Comparison of Two Different Setups for VMAT Patient-Specific QA
    Clemente, F.
    Perez-Vara, C.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] EXPERIENCE OF PATIENT-SPECIFIC QA FOR VMAT WITH DIFFERENT INSTRUMENTS.
    Declich, F.
    Bonsignore, F.
    Butti, I.
    Frigerio, C.
    Sangalli, G.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S511 - S511
  • [10] Optical Tracking Guided Patient-Specific VMAT QA with ArcCHECK
    Fan, Q.
    Park, C.
    Lu, B.
    Barraclough, B.
    Lebron, S.
    Li, J.
    Liu, C.
    Yan, G.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3470 - 3470