The Sensitivity of Gamma Index to Detect MLC Positioning Errors Using Varian EPID and ArcCHECK for Patient-Specific VMAT QA

被引:0
|
作者
Maraghechi, B. [1 ]
Darko, J. [1 ,2 ,3 ]
Davis, J. [2 ]
Mitchell, N. [2 ]
Shah, M. [2 ]
Fleck, A. [1 ,3 ]
Osei, E. [1 ,2 ,3 ]
机构
[1] Grand River Reg Canc Ctr, Kitchener, ON, Canada
[2] Univ Waterloo, Waterloo, ON, Canada
[3] Univ Guelph, Guelph, ON, Canada
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-T
引用
收藏
页码:2887 / 2887
页数:1
相关论文
共 50 条
  • [1] The sensitivity of gamma index analysis to detect multileaf collimator (MLC) positioning errors using Varian TrueBeam EPID and ArcCHECK for patient-specific prostate volumetric-modulated arc therapy (VMAT) quality assurance
    Maraghechi, Borna
    Davis, Jack
    Mitchell, Nicholas
    Shah, Meeral
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 66 - 77
  • [2] The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT
    Kim, Jung-In
    Park, So-Yeon
    Kim, Hak Jae
    Kim, Jin Ho
    Ye, Sung-Joon
    Park, Jong Min
    [J]. RADIATION ONCOLOGY, 2014, 9
  • [3] The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT
    Jung-in Kim
    So-Yeon Park
    Hak Jae Kim
    Jin Ho Kim
    Sung-Joon Ye
    Jong Min Park
    [J]. Radiation Oncology, 9
  • [4] On the sensitivity of patient-specific IMRT QA to MLC positioning errors
    Yan, Guanghua
    Liu, Chihray
    Simon, Thomas A.
    Peng, Lee-Cheng
    Fox, Christopher
    Li, Jonathan G.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 120 - 128
  • [5] The Correlation of MLCleaf Trajectory Errors and Gamma Passing Rates of Patient-Specific ArcCheck-Based QA for Varian TrueBeam VMAT
    Watanabe, Y.
    Claps, L.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E857 - E857
  • [6] Anatomy-based, patient-specific VMAT QA using EPID or MLC log files
    Defoor, Dewayne L.
    Vazquez-Quino, Luis A.
    Mavroidis, Panayiotis
    Papanikolaou, Nikos
    Stathakis, Sotirios
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 206 - 215
  • [7] On the Sensitivity of Patient-Specific IMRT QA to MLC Position Errors
    Yan, G.
    Simon, T.
    Peng, L.
    Fox, C.
    Liu, C.
    Li, J.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [8] Optical Tracking Guided Patient-Specific VMAT QA with ArcCHECK
    Fan, Q.
    Park, C.
    Lu, B.
    Barraclough, B.
    Lebron, S.
    Li, J.
    Liu, C.
    Yan, G.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3470 - 3470
  • [9] Sensitivity of Enhanced Gamma Index to Patient Specific VMAT QA
    Sethi, A.
    Cozzi, J.
    Lavvafi, H.
    Ingram, J.
    Patel, R.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E432 - E432
  • [10] Error detection sensitivity test using complex errors on three patient-specific VMAT QA systems
    Thongsawad, S.
    Srisatit, S.
    Fuangrod, T.
    [J]. INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE, 2019, 1285