Percutaneous extraction of an abandoned coiled pacing lead

被引:6
|
作者
Lickfett, L [1 ]
Jung, W [1 ]
Pizzulli, L [1 ]
Wolpert, C [1 ]
Lüderitz, B [1 ]
机构
[1] Univ Bonn, Dept Cardiol, D-5300 Bonn, Germany
来源
关键词
pacemaker; lead extraction; late migration;
D O I
10.1111/j.1540-8159.1999.tb00579.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Abandoning redundant pacing leads has been an accepted practice in most cases. Late migration of a lead Is a rare, unpredictable, and potentially lethal complication of this approach and requires immediate removal. We report the case of an atrial pacing lead that had migrated and was found coiled in the right atrium;:lt was removed by a snare catheter via a femoral approach.
引用
收藏
页码:1100 / 1102
页数:3
相关论文
共 50 条
  • [31] Extraction of left bundle branch pacing lead: a safe procedure?
    Migliore, Federico
    Aruta, Patrizia
    Cecchetto, Antonella
    Iliceto, Sabino
    Gerosa, Gino
    Catanzariti, Domenico
    EUROPACE, 2021, 23 (12): : 1921 - 1921
  • [32] PERCUTANEOUS REMOVAL OF TRANSVENOUS PACING LEAD PERFORATING THE HEART, PERICARDIUM, AND PLEURA
    DEUTSCH, LS
    DANG, H
    BRANDON, JC
    OTT, R
    ALLEN, B
    FUTERMAN, C
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (03) : 471 - 473
  • [33] Pulmonary embolization of a pacing electrode fragment complicating lead extraction
    Walters, MI
    Kaye, GC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (05): : 823 - 824
  • [34] Safety and efficacy of transvenous mechanical lead extraction in patients with abandoned leads
    Segreti, Luca
    Santoro, Mario Giannotti
    Di Cori, Andrea
    Fiorentini, Federico
    Zucchelli, Giulio
    Bernini, Giulia
    De Lucia, Raffaele
    Viani, Stefano
    Paperini, Luca
    Barletta, Valentina
    Soldati, Ezio
    Bongiorni, Maria Grazia
    EUROPACE, 2020, 22 (09): : 1401 - 1408
  • [35] Periprocedural Outcomes of Lead Extraction in Patients With or Without Abandoned Leads: A Metanalysis
    Kohli, Varun
    Khan, Abdul
    Forrest, Terry
    Ramu, Vijay
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B561 - B561
  • [36] THE IMPACT OF THE ABANDONED LEADS ON EFFICACY AND SAFETY ENDPOINT OF TRANSVENOUS LEAD EXTRACTION
    Santoro, M. Giannotti
    Segreti, L.
    Fiorentini, F.
    Bernini, G.
    Barletta, V.
    Cellamaro, T.
    Della Tommasina, V.
    Zucchelli, G.
    Di Cori, A.
    De Lucia, R.
    Soldati, E.
    Viani, S.
    Paperini, L.
    Branchitta, G.
    Carluccio, M.
    Andreini, D.
    Bongiorni, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0E) : E116 - E116
  • [37] Percutaneous extraction of a malpositioned subclavian arterial pacing lead using the retained wire technique and a vascular closure device: a case report
    Ng, Primero
    Paul, Vince
    Shetty, Sharad
    Lambert, James
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2022, 6 (06)
  • [38] NOVEL TECHNIQUE FOR DEBULKING OF LEAD VEGETATION PRIOR TO PERCUTANEOUS LEAD EXTRACTION
    Mansoor, Kanaan
    Dao, Benjamin
    Sayyed, Rameez
    Maru, Mehrette M.
    Baryun, Esam N.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 3858 - 3858
  • [39] Post heart transplant extraction of the abandoned fragments of pacing and defibrillation leads: proposed management algorithm
    Kusmierski, Krzysztof
    Przybylski, Andrzej
    Oreziak, Artur
    Sobieszczanska-Malek, Malgorzata
    Kolsut, Piotr
    Rozanski, Jacek
    KARDIOLOGIA POLSKA, 2013, 71 (02) : 159 - 163
  • [40] Successful percutaneous extraction of a remnant floating pacemaker lead
    Imaeda, Shohei
    Katsumata, Yoshinori
    Kimura, Takehiro
    Takatsuki, Seiji
    BMJ CASE REPORTS, 2021, 14 (05)