Safety and efficacy of transvenous mechanical lead extraction in patients with abandoned leads

被引:16
|
作者
Segreti, Luca [1 ]
Santoro, Mario Giannotti [1 ]
Di Cori, Andrea [1 ]
Fiorentini, Federico [1 ]
Zucchelli, Giulio [1 ]
Bernini, Giulia [1 ]
De Lucia, Raffaele [1 ]
Viani, Stefano [1 ]
Paperini, Luca [1 ]
Barletta, Valentina [1 ]
Soldati, Ezio [1 ]
Bongiorni, Maria Grazia [1 ]
机构
[1] Univ Hosp Pisa, Cardiol Dept, Via Paradisa 2, I-56124 Pisa, Italy
来源
EUROPACE | 2020年 / 22卷 / 09期
关键词
Lead extraction; Abandoned leads; Implantable cardioverter-defibrillator; Pacemaker; Safety; PROCEDURAL OUTCOMES; SINGLE-CENTER; PREDICTORS; EXPERIENCE; INFECTION; REGISTRY;
D O I
10.1093/europace/euaa134
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Optimal management of redundant or malfunctioning leads is controversial. We aimed to assess safety and efficacy of mechanical transvenous lead extraction (TLE) in patients with abandoned leads. Methods and results Consecutive TLE procedures performed in our centre from January 2009 to December 2017 were considered. We evaluated the safety and efficacy of mechanical TLE in patients with abandoned (Group 1) compared to non-abandoned (Group 2) leads. We analysed 1210 consecutive patients that required transvenous removal of 2343 leads. Group 1 accounted for 250 patients (21%) with a total of 617 abandoned leads (26%). Group 2 comprised 960 patients (79%) with 1726 leads (74%). The total number of leads (3.0 vs. 2.0), dwelling time of the oldest lead (108.00months vs. 60.00months) and infectious indications for TLE were higher in Group 1. Clinical success was achieved in 1168 patients (96.5%) with a lower rate in Group 1 (90.4% vs. 98.1%; P<0.001). Major complications occurred in only 9 patients (0.7%), without significant differences among the two groups. The presence of one or more abandoned leads [odds ratio (OR) 3.47; 95% confidence interval (CI) 1.07-11.19; P=0.037] and dwelling time of the oldest lead (OR 1.01 for a month; 95% CI 1.01-1.02; P<0.001) were associated with a higher risk of clinical failure. Conclusion Transvenous mechanical lead extraction is a safe procedure also in high-risk settings, as patients with abandoned leads. Success rate resulted a bit lower, especially in the presence of abandoned leads with long implantation time.
引用
收藏
页码:1401 / 1408
页数:8
相关论文
共 50 条
  • [1] THE IMPACT OF THE ABANDONED LEADS ON EFFICACY AND SAFETY ENDPOINT OF TRANSVENOUS LEAD EXTRACTION
    Santoro, M. Giannotti
    Segreti, L.
    Fiorentini, F.
    Bernini, G.
    Barletta, V.
    Cellamaro, T.
    Della Tommasina, V.
    Zucchelli, G.
    Di Cori, A.
    De Lucia, R.
    Soldati, E.
    Viani, S.
    Paperini, L.
    Branchitta, G.
    Carluccio, M.
    Andreini, D.
    Bongiorni, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0E) : E116 - E116
  • [2] Safety and efficacy of transvenous lead extraction of very old leads
    Pecha, Simon
    Ziegelhoeffer, Tibor
    Yildirim, Yalin
    Choi, Yeong-Hoon
    Willems, Stephan
    Reichenspurner, Hermann
    Burger, Heiko
    Hakmi, Samer
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 32 (03) : 402 - 407
  • [3] Efficacy and safety of transvenous lead extraction in the Chinese octogenarian patients
    Zhou, Xu
    Ze, Feng
    Li, Xuebin
    Wang, Bin
    CLINICAL CARDIOLOGY, 2021, 44 (07) : 971 - 977
  • [4] Transvenous lead extraction: Efficacy and safety of the procedure in octogenarian patients
    Santoro, Mario Giannotti
    Segreti, Luca
    Zucchelli, Giulio
    Barletta, Valentina
    Fiorentini, Federico
    Di Cori, Andrea
    De Lucia, Raffaele
    Bongiorni, Maria Grazia
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (04): : 382 - 387
  • [5] Transvenous lead extraction: Efficacy and safety of the procedure in female patients
    Segreti, Luca
    Bongiorni, Maria Grazia
    Barletta, Valentina
    Parollo, Matteo
    Di Cori, Andrea
    Fiorentini, Federico
    Santoro, Mario Giannotti
    De Lucia, Raffaele
    Viani, Stefano
    Grifoni, Gino
    Paperini, Luca
    Sodati, Ezio
    Mazzocchetti, Lorenzo
    Canu, Antonio Maria
    HEART RHYTHM O2, 2023, 4 (10): : 625 - 631
  • [6] Transvenous lead extraction: efficacy and safety of the procedure in octogenarian patients
    Santoro, Mario Giannotti
    Segreti, Luca
    Barletta, Valentina
    Fiorentini, Federico
    Zucchelli, Giulio
    Di Cori, Andrea
    De Lucia, Raffaele
    Della Tommasina, Veronica
    Pedrinelli, Roberto
    Bongiorni, Maria Grazia
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0J) : J18 - J19
  • [7] Safety and Efficacy of Transvenous Lead Extraction Utilizing the Evolution Mechanical Lead Extraction System A Single-Center Experience
    Sharma, Saumya
    Ekeruo, Ijeoma A.
    Nand, Nikita P.
    Raman, Ajay Sundara
    Zhang, Xu
    Reddy, Sunil K.
    Hariharan, Ramesh
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (02) : 212 - 220
  • [8] Initial experience with the Tightrail rotating mechanical dilator sheath for transvenous lead extraction: safety and efficacy
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Sahiner, M. L.
    Kaya, E. B.
    Evranos, B.
    Ozer, N.
    EUROPEAN HEART JOURNAL, 2015, 36 : 821 - 822
  • [9] SAFETY AND EFFICACY OF TRANSVENOUS EXTRACTION OF PACEMAKER AND CARDIOVERTER-DEFIBRILLATOR LEADS
    Vefali, H.
    Durkin, M.
    Singh, A.
    Agrawal, S.
    Nanda, S.
    Traub, D.
    Shirani, J.
    CARDIOLOGY, 2016, 134 : 331 - 331
  • [10] Safety and effectiveness of transvenous lead extraction in elderly patients
    Kutarski, Andrzej
    Polewczyk, Anna
    Boczar, Krzysztof
    Zabek, Andrzej
    Polewczyk, Maciej
    CARDIOLOGY JOURNAL, 2014, 21 (01) : 47 - 52