Safety and efficacy of transvenous mechanical lead extraction in patients with abandoned leads

被引:16
|
作者
Segreti, Luca [1 ]
Santoro, Mario Giannotti [1 ]
Di Cori, Andrea [1 ]
Fiorentini, Federico [1 ]
Zucchelli, Giulio [1 ]
Bernini, Giulia [1 ]
De Lucia, Raffaele [1 ]
Viani, Stefano [1 ]
Paperini, Luca [1 ]
Barletta, Valentina [1 ]
Soldati, Ezio [1 ]
Bongiorni, Maria Grazia [1 ]
机构
[1] Univ Hosp Pisa, Cardiol Dept, Via Paradisa 2, I-56124 Pisa, Italy
来源
EUROPACE | 2020年 / 22卷 / 09期
关键词
Lead extraction; Abandoned leads; Implantable cardioverter-defibrillator; Pacemaker; Safety; PROCEDURAL OUTCOMES; SINGLE-CENTER; PREDICTORS; EXPERIENCE; INFECTION; REGISTRY;
D O I
10.1093/europace/euaa134
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Optimal management of redundant or malfunctioning leads is controversial. We aimed to assess safety and efficacy of mechanical transvenous lead extraction (TLE) in patients with abandoned leads. Methods and results Consecutive TLE procedures performed in our centre from January 2009 to December 2017 were considered. We evaluated the safety and efficacy of mechanical TLE in patients with abandoned (Group 1) compared to non-abandoned (Group 2) leads. We analysed 1210 consecutive patients that required transvenous removal of 2343 leads. Group 1 accounted for 250 patients (21%) with a total of 617 abandoned leads (26%). Group 2 comprised 960 patients (79%) with 1726 leads (74%). The total number of leads (3.0 vs. 2.0), dwelling time of the oldest lead (108.00months vs. 60.00months) and infectious indications for TLE were higher in Group 1. Clinical success was achieved in 1168 patients (96.5%) with a lower rate in Group 1 (90.4% vs. 98.1%; P<0.001). Major complications occurred in only 9 patients (0.7%), without significant differences among the two groups. The presence of one or more abandoned leads [odds ratio (OR) 3.47; 95% confidence interval (CI) 1.07-11.19; P=0.037] and dwelling time of the oldest lead (OR 1.01 for a month; 95% CI 1.01-1.02; P<0.001) were associated with a higher risk of clinical failure. Conclusion Transvenous mechanical lead extraction is a safe procedure also in high-risk settings, as patients with abandoned leads. Success rate resulted a bit lower, especially in the presence of abandoned leads with long implantation time.
引用
收藏
页码:1401 / 1408
页数:8
相关论文
共 50 条
  • [31] Efficacy and safety of transvenous lead extraction using a liberal combined superior and femoral approach
    Yap, Sing-Chien
    Bhagwandien, Rohit E.
    Theuns, Dominic A. M. J.
    Yasar, Yunus Emre
    de Heide, John
    Hoogendijk, Mark G.
    Kik, Charles
    Szili-Torok, Tamas
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (02) : 239 - 248
  • [32] Subcutaneous implantable cardioverter defibrillator after transvenous lead extraction: safety, efficacy and outcome
    Giacomin, Enrico
    Falzone, Pasquale Valerio
    Dall'Aglio, Pietro Bernardo
    Pittorru, Raimondo
    De Lazzari, Manuel
    Vianello, Riccardo
    Bertaglia, Emanuele
    Tarzia, Vincenzo
    Iliceto, Sabino
    Gerosa, Gino
    Migliore, Federico
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022,
  • [33] Efficacy and reliability of transvenous ICD-lead extraction using mechanical and electrosurgical devices
    Dörnberger, V
    Bosch, R
    Bail, D
    Menon, A
    Kuehlkamp, V
    EUROPEAN HEART JOURNAL, 2002, 23 : 358 - 358
  • [34] Dual countertraction for extraction of abandoned leads with severe lead-to-lead adhesion
    Toba, Masahiro
    Nasu, Toshihiro
    Nekomiya, Nobuyoshi
    Itasaka, Ryo
    Makino, Takao
    Yokoshiki, Hisashi
    JOURNAL OF ARRHYTHMIA, 2021, 37 (06) : 1576 - 1577
  • [35] Contributions of Advanced Techniques to the Success and Safety of Transvenous Leads Extraction
    Marijon, Eloi
    Boveda, Serge
    De Guillebon, Maxime
    Jacob, Sophie
    Vahdat, Olivier
    Barandon, Laurent
    Combes, Nicolas
    Sidobre, Laurent
    Albenque, Jean-Paul
    Clementy, Jacques
    Bordachar, Pierre
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 : S38 - S41
  • [36] Extraction of ICD leads: efficacy and safety comparable with pacemaker lead extraction in a high volume center
    Knutsen, T. M.
    Platou, E. S.
    EUROPEAN HEART JOURNAL, 2016, 37 : 18 - 18
  • [37] SUBCUTANEOUS IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR AFTER TRANSVENOUS LEAD EXTRACTION: SAFETY, EFFICACY AND OUTCOME
    Migliore, F.
    Giacomin, E.
    Pittorru, R.
    Falzone, P.
    Dall'Aglio, P.
    Vianello, R.
    De Lazzari, M.
    Bertaglia, E.
    Iliceto, S.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24 (SUPPL C)
  • [38] Analysis of efficacy and safety of transvenous leads extraction and long term mortality after procedures in women and men
    Polewczyk, A.
    Jachec, W.
    Opolski, G.
    Grabowski, M.
    Janion, M.
    Kutarski, A.
    EUROPEAN HEART JOURNAL, 2015, 36 : 171 - 171
  • [39] Efficacy and safety of mechanical transvenous lead extraction: median follow-up analysis and development of an experimental model for predicting survival post-extraction
    Nasri, Shima
    Samimi, Sahar
    Eslami, Masoud
    Hematpour, Khashayar
    Eslami, Morteza
    Yarmohammadi, Hirad
    Mollazadeh, Reza
    Rahmanian, Mehrzad
    EGYPTIAN HEART JOURNAL, 2025, 77 (01):
  • [40] Outcome of transvenous lead extraction of leads older than 20 years
    Issa, Ziad F.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (11) : 3042 - 3048