Temperature dependence of spurious pulses in use of plastic scintillation detectors

被引:7
|
作者
Kawada, Y
Ito, J
Wang, QW
机构
[1] Japan Radioisotope Assoc, Bunkyo Ku, Tokyo 1138941, Japan
[2] Univ Tokyo, Fac Engn, Bunkyo Ku, Tokyo 1138656, Japan
关键词
spurious pulse; afterpulse; plastic scintillator; photomultiplier tube; temperature dependence;
D O I
10.1016/j.apradiso.2003.11.049
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Pulse-height and time spectra of afterpulses from a scintillation detector with NE102A scintillator sandwiching a Co-60 source were observed at several different temperatures. From time analysis with a slow amplifier followed by a conventional TAC, spurious pulses are grouped into two types; time-dependent afterpulses and random noise. The intensity of afterpulses decreased considerably with increasing temperature, while the intensity of random noise pulses increased abruptly above 50degreesC. Experiments, in which the temperatures of scintillator sheets and of the photomultiplier tube were changed separately, suggested that the time-dependent afterpulses were produced in the scintillator itself, while the random component arose from photomultiplier tube. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:403 / 407
页数:5
相关论文
共 50 条
  • [31] Scintillation in Low-Temperature Particle Detectors
    Poda, Denys
    [J]. PHYSICS, 2021, 3 (03): : 473 - 535
  • [32] UNIFORMITY OF RESPONSE FROM LARGE AREA PLASTIC SCINTILLATION DETECTORS
    GILLESPIE, CR
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (11): : 1724 - +
  • [33] A Systematic Characterization of the Low Energy Response of Plastic Scintillation Detectors
    Boivin, J.
    Beddar, S.
    Schmidt, D.
    Culberson, W.
    Bonde, C.
    Guillemette, M.
    Beaulieu, L.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3720 - 3720
  • [34] SUB-NANOSECOND TIMING STUDIES WITH PLASTIC SCINTILLATION DETECTORS
    SANYAL, S
    PANCHOLI, SC
    GUPTA, SL
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1976, 136 (01): : 157 - 163
  • [35] Fast-Neutron Survey With Compact Plastic Scintillation Detectors
    Preston, Rhys M.
    Tickner, James R.
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 406 - 412
  • [36] Plastic scintillation detectors for dose monitoring in digital breast tomosynthesis
    Antunes, J.
    Machado, J.
    Peralta, L.
    Matela, N.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 877 : 346 - 348
  • [37] POTTING OF PHOTOMULTIPLIERS FOR USE WITH LIQUID SCINTILLATION DETECTORS
    THOMAS, GE
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (10): : 878 - 878
  • [38] THE TEMPERATURE DEPENDENCE OF ORGANIC SCINTILLATION COUNTERS
    LIEBSON, SH
    KELLER, JW
    [J]. PHYSICAL REVIEW, 1950, 78 (03): : 305 - 305
  • [39] TEMPERATURE DEPENDENCE OF ORGANIC SCINTILLATION MATERIALS
    BIRKS, JB
    [J]. PHYSICAL REVIEW, 1954, 95 (01): : 277 - 277
  • [40] Measurement of Small Field Output Factors Using Plastic Scintillation Detectors
    Klein, D.
    Tailor, R.
    Archambault, L.
    Wang, L.
    Therriault-Proulx, F.
    Beddar, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)