Temperature dependence of spurious pulses in use of plastic scintillation detectors

被引:7
|
作者
Kawada, Y
Ito, J
Wang, QW
机构
[1] Japan Radioisotope Assoc, Bunkyo Ku, Tokyo 1138941, Japan
[2] Univ Tokyo, Fac Engn, Bunkyo Ku, Tokyo 1138656, Japan
关键词
spurious pulse; afterpulse; plastic scintillator; photomultiplier tube; temperature dependence;
D O I
10.1016/j.apradiso.2003.11.049
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Pulse-height and time spectra of afterpulses from a scintillation detector with NE102A scintillator sandwiching a Co-60 source were observed at several different temperatures. From time analysis with a slow amplifier followed by a conventional TAC, spurious pulses are grouped into two types; time-dependent afterpulses and random noise. The intensity of afterpulses decreased considerably with increasing temperature, while the intensity of random noise pulses increased abruptly above 50degreesC. Experiments, in which the temperatures of scintillator sheets and of the photomultiplier tube were changed separately, suggested that the time-dependent afterpulses were produced in the scintillator itself, while the random component arose from photomultiplier tube. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:403 / 407
页数:5
相关论文
共 50 条
  • [21] Water equivalent plastic scintillation detectors in radiation therapy
    Beddar, A. S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 1 - 6
  • [22] Mathematical method for optimal digitization and discrimination of scintillation detectors' pulses
    Saleh, H. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 802 : 16 - 25
  • [23] DEPENDENCE OF RESPONSE OF PLASTIC TRACK DETECTORS ON POSTIRRADIATION AGING TIME, TEMPERATURE, AND ATMOSPHERE
    PRICE, PB
    DRACH, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 28 (02): : 275 - 279
  • [24] The use of plastic scintillation microspheres in flow scintillation analysis
    Janda, Jiri
    Pipal, Vladimir
    [J]. APPLIED RADIATION AND ISOTOPES, 2022, 190
  • [25] INFLUENCE OF THE ACTIVATOR CONCENTRATION UPON THE TEMPERATURE-DEPENDENCE OF THE SCINTILLATION PARAMETERS OF CSI(TL) DETECTORS
    KOVALEVA, LV
    GUREVICH, NY
    VINOGRAD, EL
    NAGORNAYA, LL
    [J]. SOVIET ATOMIC ENERGY, 1987, 62 (02): : 158 - 160
  • [26] DEPENDENCE OF SPECTROMETRIC PARAMETERS OF SCINTILLATION DETECTORS ON IRRADIATION GEOMETRY
    SOBORNOV, OP
    SHCHEGLOV, OP
    [J]. PRIBORY I TEKHNIKA EKSPERIMENTA, 1974, (06): : 67 - 69
  • [27] Alpha/beta pulse shape discrimination in plastic scintillation using commercial scintillation detectors
    Bagan, H.
    Tarancon, A.
    Rauret, G.
    Garcia, J. F.
    [J]. ANALYTICA CHIMICA ACTA, 2010, 670 (1-2) : 11 - 17
  • [28] Temperature behavior of NaI(Tl) scintillation detectors
    Ianakiev, K. D.
    Alexandrov, B. S.
    Littlewood, P. B.
    Browne, M. C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (02): : 432 - 438
  • [29] GAS-FILLED AND PLASTIC SCINTILLATION DETECTORS: ADVANTAGES AND DISADVANTAGES
    Zaidi, Mohammed K.
    Naeem, Syed F.
    [J]. NEW TECHNIQUES FOR THE DETECTION OF NUCLEAR AND RADIOACTIVE AGENTS, 2009, : 181 - 192
  • [30] Advanced plastic scintillation detectors for low-background experiments
    Hodak, R.
    Buresova, H.
    Fajt, L.
    Pjatkan, R.
    Stekl, I.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (02)