Watthour meter accuracy under controlled unbalanced harmonic voltage and current conditions

被引:16
|
作者
Domijan, A [1 ]
EmbrizSantander, E [1 ]
Gilani, A [1 ]
Lamer, G [1 ]
Stiles, C [1 ]
Williams, CW [1 ]
机构
[1] FLORIDA POWER CORP,ST PETERSBURG,FL 33711
关键词
watthour meter; harmonics; power quality; unbalance; field monitoring; testing; waveform reproduction;
D O I
10.1109/61.484002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents the results of phase I of the project on the accuracy of watthour meters when subjected to closely-duplicated real-world unbalanced harmonic voltage and current conditions. Such real-world conditions involved differences in voltage and current magnitudes as well as differences in the voltage and current total harmonic distortion levels of each phase. Tests were performed on a selected sample of nine three-phase and three single-phase watthour meters. Some results showed that under a particular set of unbalanced waveforms with harmonic conditions of I-THD > 80% and V-THD > 2%, the percentage errors exhibited by these meters ranged from -10.09% to +0.52%.
引用
收藏
页码:64 / 72
页数:9
相关论文
共 50 条
  • [1] WATTHOUR METER ACCURACY ON SCR CONTROLLED RESISTANCE LOADS
    DOWNING, WC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1974, PA93 (04): : 1083 - 1089
  • [2] Harmonic current emission of PV-generation under controlled voltage conditions
    Schlabbach, Jurgen
    Gross, Andreas
    CIRCUITS AND SYSTEMS FOR SIGNAL PROCESSING , INFORMATION AND COMMUNICATION TECHNOLOGIES, AND POWER SOURCES AND SYSTEMS, VOL 1 AND 2, PROCEEDINGS, 2006, : 1056 - 1059
  • [3] Harmonic analysis model for voltage source converter under unbalanced conditions
    Zhong, Qing
    Lin, Lingxue
    Wang, Gang
    Zhang, Yao
    Wu, Zhigang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (01) : 12 - 21
  • [4] Load Compensation with Hysteresis Current Controlled SAPF under Unbalanced Mains Voltage and Nonlinear Load Conditions
    Karthi, K.
    Radhakrishnan, R.
    Baskaran, J. Muruganantha
    2017 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2017,
  • [5] Synchronization signal detection of fundamental voltage under unbalanced and harmonic distorted grid voltage conditions
    Zhou, Peng
    He, Yikang
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (01): : 78 - 84
  • [6] Robust Current Control Design of Voltage Source Converter under Unbalanced Voltage Conditions
    Gong Wenming
    Hu Shuju
    Xu Honghua
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [7] Hybrid voltage and current control strategy for virtual synchronous generator under unbalanced voltage conditions
    Wang, Yichao
    Wang, Dongrong
    Huang, Zuliang
    Li, Yan
    IET RENEWABLE POWER GENERATION, 2022,
  • [8] Iterative harmonic analysis for controlled and uncontrolled ac/dc converters under unbalanced conditions:: A compromise between model accuracy and flexibility
    Asensi, R
    Mayordomo, JG
    Orzáez, F
    Beites, LF
    8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2, 1998, : 412 - 418
  • [9] Harmonic Current Suppression for Three Phase PV Generation System under Unbalanced Grid Voltage
    Shou, Ting
    Wang, Huidong
    Zhu, Tieming
    Zhu, Lianhuan
    Wang, Qianggang
    Lou, Xiaoxuan
    Wang, Jiajia
    Zhou, Niancheng
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [10] Energy Meter Accuracy under Nonsinusoidal Conditions
    Bilik, Petr
    Prauzek, Michal
    Teng, Zhaosheng
    Wen, He
    PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013), 2013, : 304 - 307