Cooling load reduction effect in slim double skin facade (SDSF)

被引:0
|
作者
Kang, Kyungmo [1 ,2 ]
Kim, Taeyeon [1 ]
Chol, Haneul [1 ]
An, Youngsub [3 ]
Kim, Eunjin [3 ]
机构
[1] Yonsei Univ, Dept Architecture & Architectural Engn, Seoul 03722, South Korea
[2] Korea Inst Construct Technol, Dept Living & Built Environm Res, Go Yang 10223, South Korea
[3] Kolon Global Corp, Technol Res Lab, Gwacheon Si, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
SIMULATION; MODEL;
D O I
10.1088/1755-1315/294/1/012044
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The office building consumes cooling energy in the summer season. Building envelope such as different windows affects the indoor heat gain. Operation of the cavity in double skin facade (DSF) is widely used passive design and can reduce the cooling load. Many cases have applied a building envelope. However, increase the initial investments affect the interruption of the application of the DSF. Hence, this paper investigated the slim double skin facade (SDSF) for cooling load reduction effect of the ventilation cavity. Heat balance analysis was conducted using EnergyPlus to investigate a heat transfer mechanism for SDSF. Finally, based on the analysis, SDSF can significantly reduce the cooling load in the office building in the lower cost than other DSF types.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Natural ventilation in a double-skin facade
    Gratia, E
    De Herde, A
    [J]. ENERGY AND BUILDINGS, 2004, 36 (02) : 137 - 146
  • [22] Modelling natural ventilation in double skin facade
    Angeli, Diego
    Dama, Alessanro
    [J]. 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 1537 - 1542
  • [23] Thermal simulation of a double skin facade with plants
    Flores Larsen, Silvana
    Filippin, Celina
    Lesino, Graciela
    [J]. 2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 1763 - +
  • [24] Validation of the simulation models of the double skin facade
    Stec, WJ
    van Paassen, AHC
    [J]. ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1181 - 1188
  • [25] Symbiosis of the double skin facade with the HVAC system
    Stec, WJ
    van Paassen, AHC
    [J]. ENERGY AND BUILDINGS, 2005, 37 (05) : 461 - 469
  • [26] Sensitivity of the double skin facade on the outdoor conditions
    Stec, W
    van Paassen, D
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1371 - 1376
  • [27] Thermal Performance of Double Skin Facade Windows
    He, Guoqing
    [J]. 6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1964 - 1969
  • [28] Double-skin facade in Flotran CFD
    Palko, Milan
    [J]. ADVANCED BUILDING CONSTRUCTION AND MATERIALS 2013, 2014, 855 : 154 - 159
  • [29] Cooling of a South-Facing Wall Using a Double-Skin Green Facade in a Temperate Climate
    MacIvor, J. Scott
    Margolis, Liat
    [J]. PROCEEDINGS OF THE 2014 ANNUAL MEETING OF THE INTERNATIONAL PLANT PROPAGATORS SOCIETY, 2015, 1085 : 185 - 194
  • [30] Selected aerodynamic problems of double skin facade
    Palko, Milan
    Palková, Adela