Cooling load reduction effect in slim double skin facade (SDSF)

被引:0
|
作者
Kang, Kyungmo [1 ,2 ]
Kim, Taeyeon [1 ]
Chol, Haneul [1 ]
An, Youngsub [3 ]
Kim, Eunjin [3 ]
机构
[1] Yonsei Univ, Dept Architecture & Architectural Engn, Seoul 03722, South Korea
[2] Korea Inst Construct Technol, Dept Living & Built Environm Res, Go Yang 10223, South Korea
[3] Kolon Global Corp, Technol Res Lab, Gwacheon Si, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
SIMULATION; MODEL;
D O I
10.1088/1755-1315/294/1/012044
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The office building consumes cooling energy in the summer season. Building envelope such as different windows affects the indoor heat gain. Operation of the cavity in double skin facade (DSF) is widely used passive design and can reduce the cooling load. Many cases have applied a building envelope. However, increase the initial investments affect the interruption of the application of the DSF. Hence, this paper investigated the slim double skin facade (SDSF) for cooling load reduction effect of the ventilation cavity. Heat balance analysis was conducted using EnergyPlus to investigate a heat transfer mechanism for SDSF. Finally, based on the analysis, SDSF can significantly reduce the cooling load in the office building in the lower cost than other DSF types.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Thermal assessment of spray evaporative cooling in opaque double skin facade for cooling load reduction in hot arid climate
    Sotelo-Salas, Cristina
    Escobar-del Pozo, Carlos
    Esparza-Lopez, Carlos J.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 38 (38):
  • [2] Analysis of Heat Transfer in a Slim Double Skin Facade using CFD Simulation
    Choi, Haneul
    Kang, Kyungmo
    An, Youngsub
    Kim, Eunjin
    Lee, Yungyu
    Kim, Taeyeon
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 718 - 723
  • [3] Greenhouse effect in double-skin facade
    Gratia, Elisabeth
    De Herde, Andre
    [J]. ENERGY AND BUILDINGS, 2007, 39 (02) : 199 - 211
  • [4] Analysis of Reduced Cooling Load for a Multistorey-Building Incorporating a Ventilated Double Skin Facade with a Solar Chimney Channel
    Sung, Uk Joo
    Cho, Soo
    Seo, Dong Hyun
    Song, Kyoo Dong
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2013, 11 (04) : 381 - 391
  • [5] Chimney Effect Assessment of the Double-skin Facade
    QIU ZhongzhuLI PengCHOW TintaiREN JianxingWANG WenhuanSchool of Energy Environment EngineeringShanghai University of Electric PowerShanghai ChinaSchool of Mechanical EngineeringTongji UniversityShanghai ChinaDivision of Building Science TechnologyCity University of Hong KongHong Kong SARChina
    [J]. 湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 146 - 150
  • [6] Chimney effect assessment of the double-skin facade
    Qiu, Zhong-Zhu
    Li, Peng
    Chow, Tin-Tai
    Ren, Jian-Xing
    Wang, Wen-Huan
    [J]. Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 146 - 150
  • [7] Chimney Effect Assessment of the Double-skin Facade
    QIU Zhong-zhu1
    2.School of Mechanical Engineering
    3.Division of Building Science & Technology
    [J]. 湖南大学学报(自然科学版), 2009, (S1) : 146 - 150
  • [8] Natural cooling strategies efficiency in an office building with a double-skin facade
    Gratia, E
    De Herde, A
    [J]. ENERGY AND BUILDINGS, 2004, 36 (11) : 1139 - 1152
  • [9] BIO SKIN URBAN COOLING FACADE
    Yamanashi, Tomohiko
    Hatori, Tatsuya
    Ishihara, Yoshito
    Kawashima, Norihisa
    Niwa, Katsumi
    [J]. ARCHITECTURAL DESIGN, 2011, (214) : 100 - 107
  • [10] A study on appropriate temperature of phase change material applicable to double skin facade system for heating energy load reduction
    Ryu, Ri
    Seo, Janghoo
    Kim, Yongseong
    [J]. Ryu, Ri, 1600, Science and Engineering Research Support Society (08): : 1 - 12