Numerical investigation of indoor air quality in a floor heated room with different air change rates

被引:14
|
作者
Mutlu, Mustafa [1 ]
机构
[1] Bursa Uludag Univ, Vocat Sch Yenisehir Ibrahim Orhan, Air Conditioning & Refrigerat Tech Program, TR-16900 Bursa, Turkey
关键词
particle concentration; indoor air quality; floor heating; air change rates; PARTICLE DISPERSION; THERMAL COMFORT; VENTILATED ROOMS; HEATING-SYSTEMS; DEPOSITION; ENVIRONMENTS; SIMULATION; RADIATOR; CFD;
D O I
10.1007/s12273-020-0683-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
Nowadays, indoor air quality is no longer considered as providing thermal comfort. The pollutant concentration in the ambient air (CO2, O-3, particulate matter, etc.) is an essential factor affecting both indoor air quality and human health negatively. Particle motion in a room is affected by air movements caused by heating systems and infiltration and needs to be examined. Therefore, this study aims to explain how infiltration rates in a room with floor heating affect both thermal conditions and particularly the particle concentration and distribution. In this study, the discrete phase model (DPM) was used for particle tracking using commercial software ANSYS FLUENT. It was assumed that drag, lift, thermophoretic and Brownian forces were affecting particle motions. It was seen that air change rates influence both thermal comfort and energy consumption as well as particle distribution significantly. It was found that increasing air change rates causes a rise in particle concentration in all sizes of particles, specifically for the lower parts of the room (below 0.75 m from the floor). It is recommended to place air purifying devices where the outdoor sourced air infiltrates the room. Additionally, an index that contains thermal comfort and particle concentration together was defined and its distribution in the room was examined. It is found that the air change rate is a critical factor in obtaining desired indoor air quality, but outdoor air conditions may worsen the indoor quality due to air pollution. As the air change rate significantly alters the airflow in the room, both thermal comfort perception and particle concentrations vary considerably.
引用
收藏
页码:1063 / 1075
页数:13
相关论文
共 50 条
  • [21] Impact of climate change on the quality of indoor air
    Andre, Jean-Claude
    ENVIRONNEMENT RISQUES & SANTE, 2023, 22 (03):
  • [22] INVESTIGATION OF INDOOR AIR-QUALITY COMPLAINTS
    LIGHT, EN
    PRESANT, N
    IMMUNOLOGY AND ALLERGY CLINICS OF NORTH AMERICA, 1994, 14 (03) : 659 - 678
  • [23] Indoor air quality investigation on commercial aircraft
    Lee, SC
    Poon, CS
    Li, XD
    Luk, F
    INDOOR AIR, 1999, 9 (03) : 180 - 187
  • [24] INVESTIGATION OF INDOOR AIR QUALITY OF KINDERGARTENS IN NANJING
    Shen, X. Y.
    Xie, X. J.
    Huang, H.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 428 - 434
  • [25] Investigation of Indoor Air Quality in Houses of Macedonia
    Vilcekova, Silvia
    Apostoloski, Ilija Zoran
    Meciarova, L'udmila
    Burdova, Eva Kridlova
    Kisel'ak, Jozef
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (01)
  • [26] Investigation on indoor air quality and air cleaner testing in Taiwan district
    Yuan, CS
    Wu, YJ
    Lo, CC
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 10 - 15
  • [27] Characterization of indoor settled dust and investigation of indoor air quality in different micro-environments
    Sahu, Veerendra
    Elumalai, Suresh Pandian
    Gautam, Sneha
    Singh, Nitin Kumar
    Singh, Pradyumn
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2018, 28 (04) : 419 - 431
  • [28] Indoor air quality test and air distribution CFD simulation in hospital consulting room
    Yao, Jiali
    Zhong, Jiachen
    Yang, Ning
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2022, 17 : 33 - 37
  • [29] Cost-benefit analysis of different air change rates in an operating room environment
    Gormley, Thomas
    Markel, Troy A.
    Jones, Howard
    Greeley, Damon
    Ostojic, John
    Clarke, James H.
    Abkowitz, Mark
    Wagner, Jennifer
    AMERICAN JOURNAL OF INFECTION CONTROL, 2017, 45 (12) : 1318 - 1323
  • [30] On indoor air pollution and indoor air quality control
    Key Laboratory of the Three Gorges Reservoir Region's Eco-Environment, Chongqing University, Chongqing 400045, China
    不详
    Chongqing Jianzhu Daxue Xuebao, 2007, 6 (108-112):