Characterization of indoor settled dust and investigation of indoor air quality in different micro-environments

被引:29
|
作者
Sahu, Veerendra [1 ]
Elumalai, Suresh Pandian [1 ]
Gautam, Sneha [2 ]
Singh, Nitin Kumar [2 ]
Singh, Pradyumn [3 ]
机构
[1] Indian Inst Technol, Indian Sch Mines, Dept Environm Sci & Engn, Dhanbad, Bihar, India
[2] Marwadi Educ Fdn Grp Inst, Dept Environm Sci & Engn, Rajkot, Gujarat, India
[3] Washington State Univ, Dept Civil & Environm Engn, Pullman, WA 99164 USA
关键词
Indoor air quality; FTIR; FESEM; dust characterization; volatile organic carbon; India; PARTICULATE MATTER; PARTICLE-SIZE; OUTDOOR; POLLUTANTS; PM2.5; MICROENVIRONMENTS; REFLECTANCE; DEPOSITION; EMISSIONS; EXPOSURE;
D O I
10.1080/09603123.2018.1481498
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Present study reports the characterization results of settled dust particles in different indoor micro-environments of an academic institution in India. Field emission scanning electron microscope analysis of indoor dust revealed the presence of mineral particles, fly ash, and soot particles of different morphologies. Energy-dispersive X-ray spectroscopy analysis of indoor dust indicated that crystal particles are comprised of elements such as C, O, Na, Mg, Al, Si, S, Cl, K, Ca, Fe, and Ti. These elements accounted for more than 99% of the samples. The average content of O (42.7%) and C (18.9%) in the dust particles was found to be higher than their natural abundances. The concentrations of PM10, PM2.5, and PM1 were observed in the range of 88-58, 37-33, 23-29 mu g/m(3), respectively. Except temperature, other parameters such as volatile organic carbon, carbon dioxide concentration, and relative humidity were found to be within comfort limits of American Society of Heating, Refrigerating, and Air-Conditioning Engineers. Abbreviations: ASHRAE: American Society of Heating, Refrigerating, and Air-Conditioning Engineers; CO2: carbon dioxide; COPD: chronic obstructive pulmonary disease; EDX: energy-dispersive X-ray; FESEM: field emission scanning electron microscope; FTIR: Fourier transform infrared spectroscopy; IAP: indoor air pollution; IAQ: indoor air quality; HAP: household air pollution; OAP: outdoor air pollution; PM: particulate matter; VOC: volatile organic carbon; WHO: World Health Organization
引用
收藏
页码:419 / 431
页数:13
相关论文
共 50 条
  • [1] Assessment of indoor air quality and characterization of indoor settled dust in schools of Tezpur, Northeast India
    Anamika Nath
    Dimpi Saikia
    Mebaaibok L. Nonglait
    Pratibha Deka
    Air Quality, Atmosphere & Health, 2025, 18 (3) : 793 - 814
  • [2] Assessment of cyclic volatile methyl siloxanes (CVMSs) in indoor dust from different micro-environments in northern and central Vietnam
    Anh Quoc Hoang
    Hue Thi Trinh
    Ha My Nu Nguyen
    Trung Quang Nguyen
    Thi Xuyen Nguyen
    Duc, Toan Vu
    Thi Thao Nguyen
    Trung Quang Do
    Tu Binh Minh
    Tri Manh Tran
    ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2023, 45 (05) : 1711 - 1722
  • [3] Assessment of cyclic volatile methyl siloxanes (CVMSs) in indoor dust from different micro-environments in northern and central Vietnam
    Anh Quoc Hoang
    Hue Thi Trinh
    Ha My Nu Nguyen
    Trung Quang Nguyen
    Thi Xuyen Nguyen
    Toan Vu Duc
    Thi Thao Nguyen
    Trung Quang Do
    Tu Binh Minh
    Tri Manh Tran
    Environmental Geochemistry and Health, 2023, 45 : 1711 - 1722
  • [4] Characterization of triclosan and triclocarban in indoor dust from home micro-environments in Vietnam and relevance of non-dietary exposure
    Tri Manh Tran
    Hue Thi Trinh
    Hoang Quoc Anh
    Trong Van Le
    Son Ngoc Le
    Tu Binh Minh
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 732
  • [5] Exposure assessment and reference values for settled dust in indoor environments
    Perouel, Guillaume
    Keirsbulck, Marion
    Chaigneau, Thomas
    Delannoy, Matthieu
    Esteve, Williams
    Le Bot, Barbara
    Noack, Yves
    Pelfrene, Aurelie
    Glorennec, Philippe
    ENVIRONNEMENT RISQUES & SANTE, 2021, 20 (04): : 383 - 388
  • [6] Pentachlorophenol in indoor environments.: Correlation of PCP concentrations in air and settled dust from floors
    Schnelle-Kreis, J
    Scherb, H
    Gebefügi, I
    Kettrup, A
    Weigelt, E
    SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 256 (2-3) : 125 - 132
  • [7] Indoor air quality in university environments
    Di Giulio, Mara
    Grande, Rossella
    Di Campli, Emanuela
    Di Bartolomeo, Soraya
    Cellini, Luigina
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 170 (1-4) : 509 - 517
  • [8] Endotoxins in Indoor Air and Settled Dust in Primary Schools in a Subtropical Climate
    Salonen, Heidi
    Duchaine, Caroline
    Letourneau, Valerie
    Mazaheri, Mandana
    Clifford, Sam
    Morawska, Lidia
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (17) : 9882 - 9890
  • [9] Indoor air quality in university environments
    Mara Di Giulio
    Rossella Grande
    Emanuela Di Campli
    Soraya Di Bartolomeo
    Luigina Cellini
    Environmental Monitoring and Assessment, 2010, 170 : 509 - 517
  • [10] Microplastics in dust from different indoor environments
    Zhu, Jianqiang
    Zhang, Xingqing
    Liao, Kaizhen
    Wu, Pengfei
    Jin, Hangbiao
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 833