Hand-held dynamometer to measure pressure pain thresholds: A double-blinded reliability and validity study

被引:16
|
作者
Jayaseelan, Dhinu J. [1 ]
Cole, Keith R. [1 ]
Courtney, Carol A. [2 ]
机构
[1] George Washington Univ, Dept Hlth Human Funct & Rehabil Sci, Washington, DC USA
[2] Northwestern Univ, Dept Phys Therapy & Human Movement Sci, Chicago, IL 60611 USA
关键词
Algometry; Pain mechanisms; Quantitative sensory testing; Spatial summation;
D O I
10.1016/j.msksp.2020.102268
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Pain is the most common complaint reported in the musculoskeletal setting. Quantitative sensory testing (QST) assists with pain mechanism identification, although QST is typically performed in research settings. It is possible that clinical utilization of QST may improve if clinically accessible tools can be reliably and validly used. Objective: To determine if a hand-held dynamometer (HHD) can be a valid and reliable assessment of pressure pain threshold (PPT). Design: Double-blinded validation study. Methods: Eighteen healthy subjects (25.6 +/- 3.4 years old) participated in this study. Two testers independently assessed PPT using a HHD and a digital algometer. Assessments followed previously described pressure algometry protocols. Testers and subjects were each blinded to data during assessments. Results: Intra- and inter-rater reliability were excellent for the foot and face for both devices (ICC' s > 0.9). Bland-Altman plots and intraclass correlation coefficients revealed good-excellent agreement with minimal proportional bias when normalizing device force at pain threshold to the circumference of the device applicator (ICC 95%CI: 0.56-0.95). Only poor-good agreement (ICC 95% CI: 0.30-0.76) and significant proportional bias was observed when normalizing to area (pressure). Conclusions: Based on the results of this study, when force is normalized by circumference of the applicator, a HHD was found to be a valid and reliable tool for measuring PPT. Clinicians may use HHD to detect relevant pain mechanisms at fault in their evaluation and treatment of pain. Additional research in various pathologic populations is warranted.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER WITH 2 POPULATIONS
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 229 - 234
  • [2] INTERDEVICE RELIABILITY AND VALIDITY ASSESSMENT OF THE NICHOLAS HAND-HELD DYNAMOMETER
    TRUDELLEJACKSON, E
    JACKSON, AW
    FRANKOWSKI, CM
    LONG, KM
    MESKE, NB
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 20 (06): : 302 - 306
  • [3] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [4] Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer
    Janssen, Jessie C.
    Le-Ngoc, Lan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (09): : 1541 - 1547
  • [5] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER APPLIED TO ADULTS WITH MENTAL-RETARDATION
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1992, 73 (06): : 535 - 539
  • [6] Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
    Tudini, Frank
    Myers, Bradley
    Bohannon, Richard
    JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) : 222 - 228
  • [7] Reliability and Validity of Hand-Held Dynamometer and Hand-Held Sphygmomanometer for Testing Shoulder Isometric External and Internal Rotator Muscles Strength
    Bettariga, Francesco
    Lopomo, Nicola Francesco
    Civera, Fabio
    Lazzarini, Stefano Giuseppe
    Mantovani, Lisa
    Maestroni, Luca
    JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2024, 6 (04) : 386 - 393
  • [8] Validity And Reliability Of Hand-held Dynamometer In Assessing Isometric Leg Strength In Older Adults
    Lee, Chong-Do
    Lee, Samuel
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 477 - 477
  • [9] HAND-HELD DYNAMOMETER POSITIONING IMPACTS DISCOMFORT DURING QUADRICEPS STRENGTH TESTING: A VALIDITY AND RELIABILITY STUDY
    Hansen, Evan M.
    McCartney, Caitlyn N.
    Sweeney, Ryan S.
    Palimenio, Marcus R.
    Grindstaff, Terry L.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2015, 10 (01): : 62 - 68
  • [10] Development and reliability of a hand-held dynamometer device to measure the ankle dorsiflexor muscle strength
    Kimura, Masanobu
    Ogata, Yuto
    Akebi, Toru
    Ochi, Mitsuhiro
    Hachisuka, Kenji
    Saeki, Satoru
    JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2018, 5