Fast 3-D Velocity Estimation in 4-D Using a 62+62 Row-Column Addressed Array

被引:10
|
作者
Schou, Mikkel [1 ]
Jorgensen, Lasse Thurmann [1 ]
Beers, Christopher [2 ]
Traberg, Marie Sand [1 ]
Tomov, Borislav Gueorguiev [1 ]
Bo Stuart, Matthias [1 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] BK Med, State Coll, PA 16803 USA
关键词
Estimation; Apertures; Blood; Focusing; Probes; Acoustics; Blood flow measurement; row column addressed; synthetic aperture flow imaging; tensor velocity imaging (TVI); three dimensional imaging; ultrasonic transducers;
D O I
10.1109/TUFFC.2020.3016991
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This article presents an imaging scheme capable of estimating the full 3-D velocity vector field in a volume using row-column addressed arrays (RCAs) at a high volume rate. A 62 + 62 RCA array is employed with an interleaved synthetic aperture sequence. It contains repeated emissions with rows and columns interleaved with B-mode emissions. The sequence contains 80 emissions in total and can provide continuous volumetric data at a volume rate above 125 Hz. A transverse oscillation cross correlation estimator determines all three velocity components. The approach is investigated using Field II simulations and measurements using a specially built 3-MHz 62 + 62 RCA array connected to the SARUS experimental scanner. Both the B-mode and flow sequences have a penetration depth of 14 cm when measured on a tissue-mimicking phantom (0.5-dB/[MHz . cm] attenuation). Simulations of a parabolic flow in a 12-mm-diameter vessel at a depth of 30 mm, beam-to-flow angle of 90 degrees, and xy-rotation of 45 degrees gave a standard deviation (SD) of (3.3, 3.4, 0.4)% and bias of (-3.3, -3.9, -0.1)%, for (v(x), v(y), and v(z)). Decreasing the beam-to-flow angle to 60 degrees gave an SD of (8.9, 9.1, 0.8)% and bias of (-7.6, -9.5, -7.2)%, showing a slight increase. Measurements were carried out using a similar setup, and pulsing at 2 kHz yielded comparable results at 90 degrees with an SD of (5.8, 5.5, 1.1)% and bias of (1.4, -6.4, 2.4)%. At 60 degrees, the SD was (5.2, 4.7 1.2)% and bias (-4.6, 6.9, -7.4)%. Results from measurements across all tested settings showed a maximum SD of 6.8% and a maximum bias of 15.8% for a peak velocity of 10 cm/s. A tissue-mimicking phantom with a straight vessel was used to introduce clutter, tissue motion, and pulsating flow. The pulsating velocity magnitude was estimated across ten pulse periods and yielded an SD of 10.9%. The method was capable of estimating transverse flow components precisely but underestimated the flow with small beam-to-flow angles. The sequence provided continuous data in both time and space throughout the volume, allowing for retrospective analysis of the flow. Moreover, B-mode planes can be selected retrospectively anywhere in the volume. This shows that tensor velocity imaging (full 3-D volumetric vector flow imaging) can be estimated in 4-D (x, y, z, and t) using only 62 channels in receive, making 4-D volumetric imaging implementable on current scanner hardware.
引用
收藏
页码:608 / 623
页数:16
相关论文
共 50 条
  • [21] 4D Functional Imaging of the Rat Brain Using a Large Aperture Row-Column Array
    Sauvage, Jack
    Poree, Jonathan
    Rabut, Claire
    Ferin, Guillaume
    Flesch, Martin
    Rosinski, Bogdan
    An Nguyen-Dinh
    Tanter, Mickael
    Pernot, Mathieu
    Deffieux, Thomas
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 1884 - 1893
  • [22] Characterization of Low-Voltage Row-Column Addressed CMUTs for 3D Imaging Applications
    Merrien, Tony
    Boulme, Audren
    Chatain, Pascal
    Certon, Dominique
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [23] A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate
    Sanders, Jean L.
    Biliroglu, Ali Onder
    Wu, Xun
    Adelegan, Oluwafemi J.
    Yamaner, Feysel Yalcin
    Oralkan, Omer
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 767 - 776
  • [24] Improved Focusing Method for 3-D Imaging using Row-Column-Addressed 2-D Arrays
    Bouzari, Hamed
    Engholm, Mathias
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [25] 3-D Imaging using Row-Column-Addressed 2-D Arrays with a Diverging Lens: Phantom Study
    Bouzari, Hamed
    Engholm, Mathias
    Beers, Christopher
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [26] Transcutaneous Imaging of Rabbit Kidney Using 3-D Acoustic Wave Sparsely Activated Localization Microscopy With a Row-Column-Addressed Array
    Tan, Qingyuan
    Riemer, Kai
    Hansen-Shearer, Joseph
    Yan, Jipeng
    Toulemonde, Matthieu
    Taylor, Laura
    Yan, Su
    Dunsby, Christopher
    Weinberg, Peter D.
    Tang, Meng-Xing
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (12) : 3446 - 3456
  • [27] Coded Excitation with Unfocused Plane Waves for 3D Imaging Using a 2D Row Column Addressed Array
    Guezzi, Nizar
    Seong, Hyojin
    Yu, Jaesok
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [28] In vivo 3D Super-Resolution Ultrasound Imaging of a Rat Kidney using a Row-Column Array
    Taghavi, Iman
    Schou, Mikkel
    Panduro, Nathalie Sarup
    Andersen, Sofie Bech
    Tomov, Borislav G.
    Sorensen, Charlotte Mehlin
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [29] Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Feasibility Study
    Bouzari, Hamed
    Engholm, Mathias
    Beers, Christopher
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (06) : 978 - 988
  • [30] Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Phantom Study
    Bouzari, Hamed
    Engholm, Mathias
    Beers, Christopher
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (07) : 1182 - 1192