Fast 3-D Velocity Estimation in 4-D Using a 62+62 Row-Column Addressed Array

被引:10
|
作者
Schou, Mikkel [1 ]
Jorgensen, Lasse Thurmann [1 ]
Beers, Christopher [2 ]
Traberg, Marie Sand [1 ]
Tomov, Borislav Gueorguiev [1 ]
Bo Stuart, Matthias [1 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Hlth Technol, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] BK Med, State Coll, PA 16803 USA
关键词
Estimation; Apertures; Blood; Focusing; Probes; Acoustics; Blood flow measurement; row column addressed; synthetic aperture flow imaging; tensor velocity imaging (TVI); three dimensional imaging; ultrasonic transducers;
D O I
10.1109/TUFFC.2020.3016991
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This article presents an imaging scheme capable of estimating the full 3-D velocity vector field in a volume using row-column addressed arrays (RCAs) at a high volume rate. A 62 + 62 RCA array is employed with an interleaved synthetic aperture sequence. It contains repeated emissions with rows and columns interleaved with B-mode emissions. The sequence contains 80 emissions in total and can provide continuous volumetric data at a volume rate above 125 Hz. A transverse oscillation cross correlation estimator determines all three velocity components. The approach is investigated using Field II simulations and measurements using a specially built 3-MHz 62 + 62 RCA array connected to the SARUS experimental scanner. Both the B-mode and flow sequences have a penetration depth of 14 cm when measured on a tissue-mimicking phantom (0.5-dB/[MHz . cm] attenuation). Simulations of a parabolic flow in a 12-mm-diameter vessel at a depth of 30 mm, beam-to-flow angle of 90 degrees, and xy-rotation of 45 degrees gave a standard deviation (SD) of (3.3, 3.4, 0.4)% and bias of (-3.3, -3.9, -0.1)%, for (v(x), v(y), and v(z)). Decreasing the beam-to-flow angle to 60 degrees gave an SD of (8.9, 9.1, 0.8)% and bias of (-7.6, -9.5, -7.2)%, showing a slight increase. Measurements were carried out using a similar setup, and pulsing at 2 kHz yielded comparable results at 90 degrees with an SD of (5.8, 5.5, 1.1)% and bias of (1.4, -6.4, 2.4)%. At 60 degrees, the SD was (5.2, 4.7 1.2)% and bias (-4.6, 6.9, -7.4)%. Results from measurements across all tested settings showed a maximum SD of 6.8% and a maximum bias of 15.8% for a peak velocity of 10 cm/s. A tissue-mimicking phantom with a straight vessel was used to introduce clutter, tissue motion, and pulsating flow. The pulsating velocity magnitude was estimated across ten pulse periods and yielded an SD of 10.9%. The method was capable of estimating transverse flow components precisely but underestimated the flow with small beam-to-flow angles. The sequence provided continuous data in both time and space throughout the volume, allowing for retrospective analysis of the flow. Moreover, B-mode planes can be selected retrospectively anywhere in the volume. This shows that tensor velocity imaging (full 3-D volumetric vector flow imaging) can be estimated in 4-D (x, y, z, and t) using only 62 channels in receive, making 4-D volumetric imaging implementable on current scanner hardware.
引用
收藏
页码:608 / 623
页数:16
相关论文
共 50 条
  • [1] Volumetric 3-D Vector Flow Measurements using a 62+62 Row-Column Addressed Array
    Holbek, Simon
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [2] 3-D Super Resolution Imaging using a 62+62 Elements Row-Column Array
    Jensen, Jorgen Arendt
    Schou, Mikkel
    Ommen, Martin Lind
    Oygard, Sigrid Husebo
    Sams, Thomas
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Larsen, Niels Bent
    Beers, Christopher
    Tomov, Borislav Gueorguiev
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1838 - 1841
  • [3] Full Volumetric 3-D Vector Flow Imaging using a 62+62 Row-Column Array
    Schou, Mikkel
    Jorgensen, Lasse Thurmann
    Stuart, Matthias Bo
    Traberg, Marie Sand
    Tomov, Borislav Gueorguiev
    Jensen, Jorgen Arendt
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 864 - 867
  • [4] 3-D Vector Velocity Estimation with Row-Column Addressed Arrays
    Holbek, Simon
    Christiansen, Thomas Lehrmann
    Rasmussen, Morten Fischer
    Stuart, Matthias Bo
    Thomasen, Erik Vilain
    Jensen, Jorgen Arendt
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [5] 4-D Vector Doppler Imaging Using Row-Column Addressed Array
    Sun, Qiandong
    Fu, Yapeng
    Yan, Shaoyuan
    Xu, Kailiang
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2025, 72 (02) : 202 - 214
  • [6] Experimental 3-D Vector Velocity Estimation with Row-Column Addressed Arrays
    Holbek, Simon
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [7] 3-D Vector Flow Using a Row-Column Addressed CMUT Array
    Holbek, Simon
    Christiansen, Thomas Lehrmann
    Engholm, Mathias
    Lei, Anders
    Stuart, Matthias Bo
    Beers, Christopher
    Moesner, Lars Nordahl
    Bagge, Jan Peter
    Thomsen, Erik Vilain
    Jensen, Jurgen Arendt
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [8] 3-D Spatial Compounding Using a Row-Column Array
    Awad, Samer I.
    Yen, Jesse T.
    ULTRASONIC IMAGING, 2009, 31 (02) : 120 - 130
  • [9] 3D Volumetric Tensor Velocity Imaging with Low Computational Complexity Using a Row-Column Addressed Array
    Chetverikova, Kseniya
    Jensen, Jorgen Arendt
    Traberg, Marie Sand
    Stuart, Matthias Bo
    APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [10] 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1452 - 1455