Stability of Prototype Two-Piece Zirconia and Titanium Implants after Artificial Aging: An In Vitro Pilot Study

被引:54
|
作者
Kohal, Ralf-Joachim [1 ]
Finke, Hans Christian [1 ]
Klaus, Gerold [1 ]
机构
[1] Univ Freiburg, Sch Dent, Dept Prosthodont, Univ Clin Freiburg, D-79106 Freiburg, Germany
关键词
all-ceramic crowns; artificial mouth; fracture strength; two-piece zirconia implant; LOW-TEMPERATURE DEGRADATION; COMMERCIALLY PURE TITANIUM; ALL-CERAMIC RESTORATIONS; FRACTURE-RESISTANCE; FAILURE MODE; INTERFACE; STRENGTH; ALUMINA; TISSUES; SURFACE;
D O I
10.1111/j.1708-8208.2008.00116.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Zirconia oral implants are a new topic in implant dentistry. So far, no data are available on the biomechanical behavior of two-piece zirconia implants. Therefore, the purpose of this pilot investigation was to test in vitro the fracture strength of two-piece cylindrical zirconia implants after aging in a chewing simulator. Materials and Methods: This laboratory in vitro investigation comprised three different treatment groups. Each group consisted of 16 specimens. In group 1, two-piece zirconia implants were restored with zirconia crowns (zirconia copings veneered with Triceram (R); Esprident, Ispringen, Germany), and in group 2 zirconia implants received Empress (R) 2 single crowns (Ivoclar Vivadent AG, Schaan, Liechtenstein). The implants, including the abutments, in the two zirconia groups were identical. In group 3, similar titanium implants were reconstructed with porcelain-fused-to-metal crowns. Eight samples of each group were submitted to artificial aging with a long-term load test in the artificial mouth (chewing simulator). Subsequently, all not artificially aged samples and all artificially aged samples that survived the long-term loading of each group were submitted to a fracture strength test in a universal testing machine. For the pairwise comparisons in the different test groups with or without artificial loading and between the different groups at a given artificial loading condition, the Wilcoxon rank-sum test for independent samples was used. The significance level was set at 5%. Results: One sample of group 1 (veneer fracture), none of group 2, and six samples of group 3 (implant abutment screw fractures) failed while exposed to the artificial mouth. The values for the fracture strength after artificial loading with 1.2 million cycles for group 1 were between 45 and 377 N (mean: 275.7 N), in group 2 between 240 and 314 N (mean: 280.7 N), and in the titanium group between 45 and 582 N (mean: 165.7 N). The fracture strength results without artificial load for group 1 amounted to between 270 and 393 N (mean: 325.1 N), for group 2 between 235 and 321 N (mean: 281.8 N), and between 474 and 765 N (mean: 595.2 N) for the titanium group. The failure mode during the fracture testing in the zirconia implant groups was a fracture of the implant head and a bending/fracture of the abutment screw in the titanium group. Conclusions: Within the limits of this pilot investigation, the biomechanical stability of all tested prototype implant groups seems to be - compared with the possibly exerted occlusal forces - borderline for clinical use. A high number of failures occurred already during the artificial loading in the titanium group at the abutment screw level. The zirconia implant groups showed irreparable implant head fractures at relatively low fracture loads. Therefore, the clinical use of the presented prototype implants has to be questioned.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 50 条
  • [21] Two-piece zirconia implants in the posterior mandible and maxilla: A cohort study with a follow-up period of 9 years
    Brunello, Giulia
    Rauch, Nicole
    Becker, Kathrin
    Hakimi, Ahmad R.
    Schwarz, Frank
    Becker, Juergen
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (12) : 1233 - 1244
  • [22] The determination of pH of peri-implant crevicular fluid around one-piece and two-piece dental implants: A pilot study
    Karpavicius, Dainius
    Stasikelyte, Morta
    Baseviciene, Nomeda
    Sakalauskaite, Urte
    Ratkute, Saule
    Razukevicius, Dainius
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2019, 5 (03): : 236 - 242
  • [23] Influence of loading and aging on the fracture strength of an injection-molded two-piece zirconia implant restored with a zirconia abutment
    Kohal, Ralf-Joachim
    von Schierholz, Christopher
    Nold, Julian
    Spies, Benedikt C. C.
    Adolfsson, Erik
    Vach, Kirstin
    Burkhardt, Felix
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (02) : 105 - 115
  • [24] One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study
    Siddiqi, A.
    Duncan, W. J.
    De Silva, R. K.
    Zafar, S.
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [25] Fracture Resistance of a Bone-Level Two-Piece Zirconia Oral Implant System-The Influence of Artificial Loading and Hydrothermal Aging
    Kohal, Ralf J.
    Riesterer, Ellen
    Vach, Kirstin
    Patzelt, Sebastian B. M.
    Ivekovic, Aljaz
    Einfalt, Lara
    Kocjan, Andraz
    Hillebrecht, Anna-Lena
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (05)
  • [26] Clinical performance of two-piece zirconia implants in the posterior mandible and maxilla: a prospective cohort study over 2years
    Becker, Juergen
    John, Gordon
    Becker, Kathrin
    Mainusch, Saskia
    Diedrichs, Gabriele
    Schwarz, Frank
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (01) : 29 - 35
  • [27] Two-piece zirconia implants supporting all-ceramic crowns: Six-year results of a prospective cohort study
    Cionca, Norbert
    Hashim, Dena
    Mombelli, Andrea
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (06) : 695 - 701
  • [28] Clinical evaluation of two-piece zirconia abutments with bonded titanium inserts for implant-supported restorations
    Lin, Yu-Ting
    Shen, Yu-Fu
    Wei, Pein-Chi
    Hsu, Kuang-Wei
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (03): : 449 - 454
  • [29] Biomechanical evaluation of 3-unit fixed partial dentures on monotype and two-piece zirconia dental implants
    Melo de Matos, Jefferson David
    Scalzer Lopes, Guilherme da Rocha
    Nomura Nakano, Leonardo Jiro
    Ramos, Nathalia de Carvalho
    Lucena de Vasconcelos, John Eversong
    Bottino, Marco Antonio
    Mendes Tribst, Joao Paulo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (03) : 239 - 246
  • [30] Clinical evaluation and patient related outcomes of one- and two-piece zirconia implants at five years of loading: A case series study
    Sala, Leticia
    Zufia, Juan
    Blasi, Gonzalo
    Carrillo-de-Albornoz, Ana
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (04) : 577 - 585