Asymmetric speed modulation of a rotary blood pump affects ventricular unloading

被引:42
|
作者
Pirbodaghi, Tohid [1 ]
Weber, Alberto [2 ]
Axiak, Shannon [3 ]
Carrel, Thierry [2 ]
Vandenberghe, Stijn [1 ]
机构
[1] Univ Bern, ARTORG Cardiovasc Engn, CH-3010 Bern, Switzerland
[2] Univ Hosp Bern, Inselspital, Dept Cardiac Surg, CH-3010 Bern, Switzerland
[3] Univ Bern, Dept Vet Anesthesia, CH-3010 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
Rotary blood pumps; Speed modulation; Systole and diastole; Pulsatile flow; In vivo study; ASSIST DEVICE SUPPORT; PULSATILE; FLOW; NONPULSATILE; PERFUSION; RECOVERY; FAILURE;
D O I
10.1093/ejcts/ezs299
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Rotary blood pumps (RBPs) running at a constant speed are routinely used for the mechanical support of the heart in various clinical applications, from short-term use in heart-lung machines to long-term support of a failing heart. Their operating range is delineated by suction and regurgitation events, leaving limited control on the cardiac workload. This study investigates whether different ratios of systolic/diastolic support are advantageous over a constant-speed operation. METHODS: In order to effectively control the load on the heart, this study aimed at developing a pulsatile control algorithm for rotary pumps to investigate the impact of pump speed modulation during systole and diastole on the left ventricle unloading. The CentriMag (TM) RBP with a modified controller was implanted in four sheep via a left thoracotomy and cannulated from the ventricular apex to the descending aorta. To modulate the pump speed synchronized with the heartbeat, custom-made real-time software detected the QRS complex of the electrocardiogram and controlled the pump speed during systole and diastole. Four different speed modulations with the same average speed but different systolic and diastolic speeds were compared with the baseline and the constant speed support. Left ventricular (LV) pressure and volume, coronary flow and pump flow were analysed to examine the influence of the pump speed modulation. RESULTS: Pulsatile setting reduces the cardiac workload to 64% of the baseline and 72% of the constant speed value. Maximum unloading is obtained with the highest speed during diastole and high-pulse amplitude. End-diastolic volume in the pulsatile modes varied from 85 to 94% of the baseline and 96 to 107% of the constant speed value. Consequently, the mechanical load on the heart can be adjusted to provide assuagement, which may lead to myocardial recovery. The higher pump speed during systole results in an increase in the pulse pressure up to 140% compared with the constant speed. CONCLUSIONS: The present study is an initial step to more accurate speed modulation of RBPs to optimize the cardiac load control. To develop future control algorithms, the concept of high speed during diastole having a maximal unloading effect on the LV and high speed during systole increasing the pulse pressure is worth considering.
引用
收藏
页码:383 / 388
页数:6
相关论文
共 50 条
  • [41] Rotary blood pump flow spontaneously increases during exercise under constant pump speed: Results of a chronic study
    Akimoto, T
    Yamazaki, K
    Litwak, P
    Litwak, KN
    Tagusari, O
    Mori, T
    Antaki, JF
    Kameneva, MV
    Watach, MJ
    Umezu, M
    Tomioka, J
    Kormos, RL
    Koyanagi, H
    Griffith, BP
    ARTIFICIAL ORGANS, 1999, 23 (08) : 797 - 801
  • [42] Effect of Left Ventricular Unloading by Pump Speed Adjustment on Myocardial Flow in Continuous-flow Left Ventricular Assist Device Patients
    Yuzefpolskaya, Melana
    Ladanyi, Annamaria
    Bokhari, Sabahat
    Jorde, Ulrich P.
    Colombo, Paolo C.
    ASAIO JOURNAL, 2023, 69 (05) : 460 - 466
  • [43] The effect of sudden failure of a rotary blood pump on left ventricular performance in normal and failing hearts
    Nishida, T
    Meyns, B
    Zietkiewicz, M
    Perek, B
    Xia, ZY
    Goebel, C
    Reul, H
    Flameng, W
    ARTIFICIAL ORGANS, 2000, 24 (11) : 893 - 898
  • [44] Simulation of Changes in Myocardial Tissue Properties During Left Ventricular Assistance With a Rotary Blood Pump
    Martina, Jerson R.
    Bovendeerd, Peter H. M.
    de Jonge, Nicolaas
    de Mol, Bas A. J. M.
    Lahpor, Jaap R.
    Rutten, Marcel C. M.
    ARTIFICIAL ORGANS, 2013, 37 (06) : 531 - 540
  • [45] DEVELOPMENT OF THE MARSEILLES PULSATILE ROTARY BLOOD PUMP FOR PERMANENT IMPLANTABLE LEFT-VENTRICULAR ASSISTANCE
    MONTIES, JR
    HAVLIK, P
    MESANA, T
    TRINKL, J
    TOURRES, JL
    DEMUNCK, JL
    ARTIFICIAL ORGANS, 1994, 18 (07) : 506 - 511
  • [46] The impact of rotary blood pump in conjunction with mechanical ventilation on ventricular energetic parameters - Numerical simulation
    De Lazzari, C.
    Darowski, M.
    Ferrari, G.
    Pisanelli, D. M.
    Tosti, G.
    METHODS OF INFORMATION IN MEDICINE, 2006, 45 (05) : 574 - 583
  • [47] Digitization of pumping speed curves of rotary vacuum pump
    Huang, Huayan, 1600, Science Press (34):
  • [48] Platelet activation following rotary pump speed increase
    Snyder, T.A.
    Watach, M.J.
    Litwak, K.N.
    Wagner, W.R.
    ASAIO Journal, 2000, 46 (02)
  • [49] Effects of the Design of a Rotary Blood Pump on Hemocompatibility
    M. V. Denisov
    M. Walter
    S. Leonhard
    D. V. Telyshev
    Biomedical Engineering, 2021, 54 : 327 - 332
  • [50] State transitions in an implantable rotary blood pump
    Lovell, NH
    Ayre, PJ
    PROCEEDINGS OF THE SECOND IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2004, : 69 - 72