Robust 3D Active Shape Model for the Segmentation of the Left Ventricle in MRI

被引:3
|
作者
Santiago, Carlos [1 ]
Nascimento, Jacinto C. [1 ]
Marques, Jorge S. [1 ]
机构
[1] Inst Super Tecn, Inst Syst & Robot, Lisbon, Portugal
来源
PATTERN RECOGNITION AND IMAGE ANALYSIS (IBPRIA 2015) | 2015年 / 9117卷
关键词
Active shape model; 3D segmentation; Cardiac MRI; Interpolation; CARDIAC MRI; APPEARANCE;
D O I
10.1007/978-3-319-19390-8_32
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
3D Active shape models use a set of annotated volumes to learn a shape model. The shape model is defined by a fixed number of landmarks at specific locations and takes shape constraints into account in the segmentation process. A relevant problem in which these models can be used is the segmentation of the left ventricle in 3D MRI volumes. In this problem, the annotations correspond to a set of contours that define the LV border at each volume slice. However, each volume has a different number of slices (i.e., a different number of landmarks), which makes model learning difficult. Furthermore, motion artifacts and the large distance between slices make interpolation of voxel intensities a bad choice when applying the learned model to a test volume. These two problems raise the following questions: (1) how can we learn a shape model from volumes with a variable number of slices? and (2) how can we segment a test volume without interpolating voxel intensities between slices? This paper provides an answer to these questions and proposes a 3D active shape model that can be used to segment the left ventricle in cardiac MRI.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
  • [21] A NEW ROBUST ACTIVE SHAPE MODEL FORMULATION FOR CARDIAC MRI SEGMENTATION
    Santiago, Carlos
    Nascimento, Jacinto C.
    Marques, Jorge S.
    2016 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2016, : 4112 - 4115
  • [22] CPS-based fully automatic cardiac left ventricle and left atrium segmentation in 3D MRI
    Ahmad, Ibtihaj
    Hussain, Farhan
    Khan, Shoab Ahmad
    Akram, Usman
    Jeon, Gwanggil
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2019, 36 (05) : 4153 - 4164
  • [23] Left-ventricle segmentation in real-time 3D echocardiography using a hybrid active shape model and optimal graph search approach
    Zhang, Honghai
    Abiose, Ademola K.
    Campbell, Dwayne N.
    Sonka, Milan
    Martins, James B.
    Wahle, Andreas
    MEDICAL IMAGING 2010: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2010, 7626
  • [24] MRI segmentation by active contours model, 3D reconstruction and visualization
    López-Hernández, JM
    Velásquez-Aguilar, JG
    Eighth International Symposium on Laser Metrology: MACRO-, MICRO-, AND NANO-TECHNOLOGIES APPLIED IN SCIENCE, ENGINEERING, AND INDUSTRY, 2005, 5776 : 333 - 339
  • [25] Robust MR image segmentation using 3D partitioned active shape models
    Zhao, Zheen
    Teoh, Eam Khwang
    2006 9TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION, VOLS 1- 5, 2006, : 2416 - +
  • [26] Quantitative 3D analysis of shape dynamics of the Left Ventricle
    Scowen, BC
    Smith, SL
    Vannan, MA
    Arsenault, M
    PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1998, 1998, 3337 : 164 - 175
  • [27] Cine Cardiac MRI Slice Misalignment Correction Towards Full 3D Left Ventricle Segmentation
    Dangi, Shusil
    Linte, Cristian A.
    Yaniv, Ziv
    MEDICAL IMAGING 2018: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2018, 10576
  • [28] Segmentation of the Left Ventricle From Ultrasound Using Random Forest with Active Shape Model
    Belous, Gregg
    Busch, Andrew
    Rowlands, David
    2013 FIRST INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE, MODELLING AND SIMULATION (AIMS 2013), 2013, : 315 - 319
  • [29] Segmentation of the left ventricle in cardiac cine MRI using a shape-constrained snake model
    Wu, Yuwei
    Wang, Yuanquan
    Jia, Yunde
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2013, 117 (09) : 990 - 1003
  • [30] Automatic segmentation of the left ventricle in 3D SPECT data by registration with a dynamic anatomic model
    Dornheim, L
    Tönnies, KD
    Dixon, K
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 1, 2005, 3749 : 335 - 342