Lumbar total disc replacement: correlation of clinical outcome and radiological parameters

被引:12
|
作者
Boss, Oliver L. [1 ]
Tomasi, S. Ottavio [1 ]
Baeurle, Barbara [1 ]
Sgier, Friedrich [1 ]
Hausmann, Oliver N. [1 ]
机构
[1] Hirslanden Clin St Anna, Neuro & Spine Ctr, CH-6006 Luzern, Switzerland
关键词
Lumbar total disc replacement; Arthroplasty; Outcome; Radiology; CHARITE(TM) ARTIFICIAL DISC; LOW-BACK-PAIN; FOLLOW-UP; PRODISC-II; SPINE; ARTHROPLASTY; FUSION; INSTRUMENT; HEALTH; DEGENERATION;
D O I
10.1007/s00701-013-1774-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The objective of this study was to correlate various radiological parameters with clinical outcome in patients who had undergone lumbar total disc replacement (TDR). Lumbar TDR is one possible treatment option in patients with low back pain (LBP), offering an alternative to lumbar fusion. Favourable clinical outcome hinges on a number of radiological parameters, such as mobility, sintering, and-most importantly-accurate positioning of the implant. A total of 46 patients received a prosthetic disc because of degenerative lumbar disc disorders. Follow-up evaluation included analysis of radiographs and subjective rating of the clinical status by the patient using the North American Spine Society (NASS) patient questionnaire, visual analogue scale (VAS) for pain and state of health, and the EuroQol EQ-5D. Radiological follow-up took place after 2 years. Coronal and sagittal positions of the prosthesis, intervertebral disc height, facet joint pressure, mobility, sintering, and calcification were evaluated. Optimal positioning of the prosthesis was defined as a central coronal position and a most dorsal position in the sagittal plane. Based on the radiologically determined placement of the prosthesis, the patient population was divided into three groups, i.e., prosthesis ideally placed (< 2 mm), discretely shifted (2-3 mm), or suboptimally placed (> 3 mm). Overall, 81 % of patients stated that they would undergo the operation again. Health status was stable at a VAS score of 7.04 points 2 years after TDR, compared to 3.97 points before TDR. Mean working capacity had increased from 53 % preoperatively to 88 % 2 years after TDR. Overall, 39 % of the prostheses were rated as ideally positioned, while 13 % were discretely shifted and 48 % were suboptimally placed with respect to one of the radiological criteria. In 80.4 % of patients, follow-up assessment after a parts per thousand yen2 years indicated good mobility at the operated segment, while calcification was noted in 4 % and sintering was detected in 15 % of the implants. Our data indicate poor correlation between clinical outcome and position of the prosthesis. Although 48 % of the implants were suboptimally placed in either the coronal or sagittal plane, most of the patients reached a very good clinical outcome. However, suboptimally placed devices appeared to cause significantly more neurological symptoms in long-term follow-up.
引用
收藏
页码:1923 / 1930
页数:8
相关论文
共 50 条
  • [1] Lumbar total disc replacement: correlation of clinical outcome and radiological parameters
    Oliver L. Boss
    S. Ottavio Tomasi
    Barbara Bäurle
    Friedrich Sgier
    Oliver N. Hausmann
    [J]. Acta Neurochirurgica, 2013, 155 : 1923 - 1930
  • [2] Clinical and Radiological Outcome of a New Total Cervical Disc Replacement Design
    Mehren, Christoph
    Heider, Franziska
    Sauer, Daniel
    Kothe, Ralph
    Korge, Andreas
    Hitzl, Wolfgang
    Wuertz-Kozak, Karin
    [J]. SPINE, 2019, 44 (04) : E202 - E210
  • [3] Subsidence after total lumbar disc replacement is predictable and related to clinical outcome
    Kitzen, J.
    Verbiest, V.
    Buil, I
    Schotanus, M. G. M.
    van Rietbergen, B.
    van Kuijk, S. M. J.
    van Rhijn, L. W.
    Willems, P. C. P. H.
    [J]. EUROPEAN SPINE JOURNAL, 2020, 29 (07) : 1544 - 1552
  • [4] Subsidence after total lumbar disc replacement is predictable and related to clinical outcome
    J. Kitzen
    V. Verbiest
    I. Buil
    M. G. M. Schotanus
    B. van Rietbergen
    S. M. J. van Kuijk
    L. W. van Rhijn
    P. C. P. H. Willems
    [J]. European Spine Journal, 2020, 29 : 1544 - 1552
  • [5] Interdependence Between Disc Space Height, Range of Motion and Clinical Outcome in Total Lumbar Disc Replacement
    Siepe, Christoph J.
    Hitzl, Wolfgang
    Meschede, Peter
    Sharma, Ajay K.
    Khattab, Mohamed F.
    Mayer, Michael H.
    [J]. SPINE, 2009, 34 (09) : 904 - 916
  • [6] Long-term clinical outcome of the Charité III total lumbar disc replacement
    J. Kitzen
    M. G. M. Schotanus
    S. M. J. van Kuijk
    E. M. C. Jutten
    N. P. Kort
    L. W. van Rhijn
    P. C. Willems
    [J]. European Spine Journal, 2020, 29 : 1527 - 1535
  • [7] Long-term clinical outcome of the Charite III total lumbar disc replacement
    Kitzen, J.
    Schotanus, M. G. M.
    van Kuijk, S. M. J.
    Jutten, E. M. C.
    Kort, N. P.
    van Rhijn, L. W.
    Willems, P. C.
    [J]. EUROPEAN SPINE JOURNAL, 2020, 29 (07) : 1527 - 1535
  • [8] Clinical results of Charite lumbar total disc replacement
    Regan, JJ
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 2005, 36 (03) : 323 - +
  • [9] Total lumbar disc replacement
    Mayer, HM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (08): : 1029 - 1037
  • [10] Lumbar total disc replacement
    Grob, D.
    [J]. ORTHOPADE, 2009, 38 (01): : 93 - 99