Interdependence Between Disc Space Height, Range of Motion and Clinical Outcome in Total Lumbar Disc Replacement

被引:39
|
作者
Siepe, Christoph J. [1 ]
Hitzl, Wolfgang [2 ]
Meschede, Peter
Sharma, Ajay K. [3 ]
Khattab, Mohamed F. [4 ]
Mayer, Michael H.
机构
[1] Spine Ctr, OrthoCtr Munich, Orthopaed Clin Munich Harlaching, D-81547 Munich, Germany
[2] Paracelsus Med Univ Salzburg, Res Off, Salzburg, Austria
[3] Penang Adventist Hosp, George Town, Malaysia
[4] Ain Shams Univ, Demerdash Univ Hosp, Dept Orthopaed, Cairo, Egypt
关键词
total disc replacement; spine arthroplasty; lumbar spine; segmental motion; disc height; clinical results prospective studies; CHARITE(TM) ARTIFICIAL DISC; INVESTIGATIONAL DEVICE EXEMPTION; PRODISC-II; FOLLOW-UP; SURGICAL TECHNIQUE; SAGITTAL BALANCE; INTERBODY FUSION; DEGENERATION; ARTHROPLASTY; FACET;
D O I
10.1097/BRS.0b013e31819966b0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Clinical and radiologic assessment obtained from an ongoing prospective trial following total lumbar disc replacement (TDR) with ProDisc II. Objective. To analyze the interaction between the parameters of disc space height (DSH), range of motion (ROM) and clinical outcome scores following TDR. Summary of Background Data. The interdependence between DSH, ROM and the clinical symptomatology has been well documented for patients with degenerative disc disease, fusion candidates and healthy control subjects. In the case of TDR, previously published data show conflicting results. Methods. All TDRs were performed monosegmentally at L4/5 or L5-S1. The clinical outcome assessment included the patient's subjective outcome evaluation, Visual Analogue Scale, and Oswestry Disability Index scores (ODI). The radiologic evaluation included measurement of the mean, anterior and posterior DSH, as well as the ROM. The parameters were correlated pre- and postoperatively with each other. Results. Data from 62 patients with an average follow-up of 42.4 months (range: 24.2-77.6 months) were included in this study. Visual Analogue Scale and ODI scores showed a significant and maintained improvement in comparison to preoperative levels (P < 0.0001). The DSH increased from 5.7 mm (range: 2-11.3 mm) to 11.2 mm (range: 8-13.4 mm), whereas ROM decreased from 8.1 (range: 0 degrees-23.1 degrees) to 5.1 (range: 0 degrees-12.8 degrees). This loss in ROM was significant following TDR at L5-S1 (P < 0.01). Preoperative DSH and ROM were positively correlated with postoperative segmental ROM (r = 0.45, P < 0.002 and r = 0.35, P < 0.01). The highest satisfaction rates were observed in the group of patients with the smallest preoperative DSH of < 4.5 mm (P < 0.024). Conclusion. A significant interdependence was observed between the parameters DSH, ROM and the clinical outcome following TDR. Whilst the DSH is restored, TDR leads to a significant decrease in postoperative ROM, particularly at the lumbosacral junction. Higher preoperative DSH and ROM revealed a beneficial effect on the postoperative segmental mobility. The subjective outcome evaluation indicates that TDR is a viable treatment option even in advanced stages of degenerative disc disease in the absence of other contraindications, in particular facet joint arthropathies.
引用
收藏
页码:904 / 916
页数:13
相关论文
共 50 条
  • [1] Re: Siepe CJ, Hitzl W, Meschede P, et al. Interdependence between disc space height, range of motion and clinical outcome in total lumbar disc replacement. Spine 2009; 34: 904-16.
    Leivseth, Gunnar
    Brinckmann, Paul
    [J]. SPINE, 2010, 35 (17) : 1660 - 1660
  • [2] Measurement error of lumbar total disc replacement range of motion
    Lim, MR
    Loder, RT
    Huang, RC
    Lyman, S
    Zhang, K
    Sama, A
    Papadopoulos, EC
    Warner, K
    Girardi, FP
    Cammisa, FP
    [J]. SPINE, 2006, 31 (10) : E291 - E297
  • [3] Influence of inlay height on motion characteristics of lumbar segments in total disc replacement
    Weisskopf, M.
    Ohnsorge, J. A. K.
    Martini, F.
    Niethard, F. U.
    Birnbaum, K.
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2008, 146 (04): : 452 - 457
  • [4] The effect of lumbar total disc replacement on the spinopelvic alignment and range of motion of the lumbar spine
    Chung, Sung Soo
    Lee, Chong Suh
    Kang, Chang Seok
    Kim, Sang Hyun
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (05): : 307 - 311
  • [5] Lumbar total disc replacement: correlation of clinical outcome and radiological parameters
    Oliver L. Boss
    S. Ottavio Tomasi
    Barbara Bäurle
    Friedrich Sgier
    Oliver N. Hausmann
    [J]. Acta Neurochirurgica, 2013, 155 : 1923 - 1930
  • [6] Lumbar total disc replacement: correlation of clinical outcome and radiological parameters
    Boss, Oliver L.
    Tomasi, S. Ottavio
    Baeurle, Barbara
    Sgier, Friedrich
    Hausmann, Oliver N.
    [J]. ACTA NEUROCHIRURGICA, 2013, 155 (10) : 1923 - 1930
  • [7] Correlation between range of motion and outcome after lumbar total disc replacement: 8.6-year follow-up
    Huang, RC
    Girardi, FP
    Cammisa, FP
    Lim, MR
    Tropiano, P
    Marnay, T
    [J]. SPINE, 2005, 30 (12) : 1407 - 1411
  • [8] Total lumbar disc replacement
    Mayer, HM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (08): : 1029 - 1037
  • [9] Lumbar Total Disc Replacement
    Gill, Norman W.
    Konitzer, Lisa N.
    Hoppes, Carrie W.
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2011, 41 (03): : 200 - 200
  • [10] Lumbar total disc replacement
    Grob, D.
    [J]. ORTHOPADE, 2009, 38 (01): : 93 - 99